PLN60 60w Constant Current LED/Lighting Power Supplies

60W Single Output LED Power Supply

Universal AC input

Fully isolated plastic case with IP64 level for indoor outdoor installations

Built-in constant current limiting circuit with adjustable Over Current Protection level

Built-in active Power Factor Correction function

Cooling by free air convection

UL310 Class 2 power unit

Model Number

Output Voltage

Output Amps

Ripple and Noise

Over Voltage Protection

Efficiency

PLN60-12

12 Volts(DC)

5.0 Amps

2.0Vpk-pk (Note 1)

13.8~16Volts(DC) Shutdown o/p voltage, re-power

83%

PLN60-15

15 Volts(DC)

4.0 Amps

2.4Vpk-pk (Note 1)

17.5~21Volts(DC) Shutdown o/p voltage, re-power

84.5%

PLN60-20

20 Volts(DC)

3.0 Amps

1.8Vpk-pk (Note 1)

22.8~25Volts(DC) Shutdown o/p voltage, re-power

86.5%

PLN60-24

24 Volts(DC)

2.5 Amps

2.7Vpk-pk (Note 1)

28~32Volts(DC) Shutdown o/p voltage, re-power

86.5%

PLN60-27

27 Volts(DC)

2.3 Amps

2.7Vpk-pk (Note 1)

31~35Volts(DC) Shutdown o/p voltage, re-power

87%

PLN60-36

36 Volts(DC)

1.7 Amps

3.6Vpk-pk (Note 1)

41~46Volts(DC) Shutdown o/p voltage, re-power

87%

PLN60-48

48 Volts(DC)

1.3 Amps

4.6Vpk-pk (Note 1)

54~60Volts(DC) Shutdown o/p voltage, re-power

88%

PLN60 series

Input Specifications

Input Voltage Range

90-264VAC, 127~370Volts(DC) (Note 4)

Input Current

0.8 Amps max @ 115VAC; 0.4 Amps max @ 230VAC

Frequency Range

47-63 Hz

Inrush Current

40 Amps @ 230VAC (Cold start)

Leakage Current

< 0.5mA / 240VAC

DC Voltage Adjust (typ.)

Can be adjust by internal potential meter SVR1

Power Factor Correction

PF> 0.9/ 230VAC >0.98/ 115VAC

General Specifications

Isolation

4250VAC Input - Output

Efficiency

83%

Safety Approvals

UL1310 Class 2, TUV EN61347-1, EN61347-2-13, CAN/CSA C22.2 No. 223-M91(except for 48V)

Insulation Resistance

?100M?/500 Volts / 25°C / 70%RH

EMI

Compliance to EN55015, EN55022B (CISPR22B)

EMS

Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN55024, EN61547, light industry level, criteria A

Harmonic Current

Compliance to EN61000-3-2,-3C (>50% load); EN61000-3-3

Environmental Specifications

Operating Temperature

-30°C to +50°C (See Derate Curve)

Storage Temperature

-40°C to +80°C, 10~95% RH

Relative Humidity

20 to +90% RH non cond

MTBF

497.8KHrs min, MIL-HDBK-217F(25°C)

Vibration

10~500Hz, 2G10min./1cycle, period for 60min. each along X, Y, Z axes

Cooling

free air convection

IP Rating

IP64

Temperature Coefficient

±0.03% / °C (0-50°C)

Output Specifications

Output Voltage

12 Volts(DC)

Output Amps

5.0 Amps

Load Regulation

±10%

Line Regulation

±4.0%

Ripple and Noise

2.0Vpk-pk (Note 1)

Over Voltage Protection

13.8~16Volts(DC) Shutdown o/p voltage, re-power

Current Adjustment Range

3~-25% Can be adjust by internal potential meter SVR1

Over Current Protection

95~110% 12Volts(DC) only 130%max 15~48Volts(DC) Constant Current limiting,auto recov

Over Temperature Protection

95°C ±10°C (TSW1) detect on heatsink of power transistor Shutdown o/p voltage, auto recover

Short Circuit Protection

Hiccup mode, auto recover (Note 3)

Rise Time

1500mS, 100mS/230VAC 3000mS. 100mS/115VAC

Voltage Tolerance

±10% (Note 2)

Physical Specifications

Size (mm)

181 x 61.5 x 35 mm

Size (Inches)

7.13” x2.42” x 1.38”

Weight (g)

500g

Weight (oz)

17.64 oz

Notes

1. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

2. Tolerance : includes set up tolerance, line regulation and load regulation.

3. Please refer to OLP characteristics.

4. Derating may be needed under low input voltage. Please check the derating curve for more details.

5. Output voltage can be adjusted through the SVR1 on the PCB ; limit of output constant current level can be adjusted through the SVR2 on the PCB.

All specifications are typical at nominal input, full load, and 25°C unless otherwise noted

Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.