Order by phone: 1-800-823-8082 / +1-508-964-6300 M-F 8:30am to 5:30pm EST

PLN30 30 Watt Constant Current LED/Lighting Power Supplies

30W Single Output Switching Power Supply

Universal AC input

Fully isolated plastic case with IP64 level for indoor outdoor installations

Built-in constant current limiting circuit with adjustable Over Current Protection level

Built-in active Power Factor Correction function

Cooling by free air convection

UL310 Class 2 power unit

Model Number

Output Voltage

Output Amps

Ripple and Noise

Over Voltage Protection

Efficiency

PLN30-9 9.0vdc 8.0 Amps

2.6Vpk-pk (Note 1)

10~14Volts(DC) Shutdown o/p voltage, re-power

80%

PLN30-12 12vdc 8.0 Amps

2.0Vpk-pk (Note 1)

14~16Volts(DC) Shutdown o/p voltage, re-power

83%

PLN30-15 15vdc 5.4 Amps

2.6Vpk-pk (Note 1)

17~22Volts(DC) Shutdown o/p voltage, re-power

84%

PLN30-20 20vdc 3.7 Amps

2.0Vpk-pk (Note 1)

23~26Volts(DC) Shutdown o/p voltage, re-power

84%

PLN30-24 24vdc 3.3 Amps

2.6Vpk-pk (Note 1)

27~34Volts(DC) Shutdown o/p voltage, re-power

85%

PLN30-27 27vdc 3.0 Amps

2.3Vpk-pk (Note 1)

31~35Volts(DC) Shutdown o/p voltage, re-power

85%

PLN30-36 36vdc 1.9 Amps

4.5Vpk-pk (Note 1)

40~50Volts(DC) Shutdown o/p voltage, re-power

86%

PLN30-48 48vdc 1.7 Amps

3.7Vpk-pk (Note 1)

53~63Volts(DC) Shutdown o/p voltage, re-power

86%

PLN30 series

Input Specifications

Input Voltage Range

90-264VAC

Input Current

0.4 Amps max @ 115VAC; 0.2 Amps max @ 230VAC

Frequency Range

47-63 Hz

Inrush Current

40 Amps @ 230VAC (Cold start)

Leakage Current

< 0.5mA / 230VAC

DC Voltage Adjust (typ.)

±10% (Note 4)

Power Factor Correction

PF> 0.9/ 230VAC >0.95/ 115VAC

General Specifications

Isolation

3000VAC Input - Output

Efficiency

80%

Safety Approvals

UL1310 Class 2 TUV EN61347-1, EN61347-2-13, CAN/CSA C22.2 No. 223-M91(except for 48V)

Insulation Resistance

?100M?/500 Volts / 25°C / 70%RH

EMI

Compliance to EN55015

EMS

Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN55024, EN61547, light industry level, criteria A

Harmonic Current

Compliance to EN61000-3-2,-3C (>80% load), D(>50% load); EN61000-3-3

Environmental Specifications

Operating Temperature

-30°C to +50°C (See Derate Curve)

Storage Temperature

-40°C to +80°C, 10~95% RH

Relative Humidity

20 to +90% RH non cond

MTBF

621.4KHrs min, MIL-HDBK-217F(25°C)

Vibration

10~500Hz, 2G10min./1cycle, period for 60min. each along X, Y, Z axes

Cooling

free air convection

IP Rating

IP64

Temperature Coefficient

±0.06% / °C (0-50°C)

Output Specifications

Output Voltage

9.0vdc

Output Amps

8.0 Amps

Load Regulation

±10%

Line Regulation

±3.0%

Ripple and Noise

2.6Vpk-pk (Note 1)

Over Voltage Protection

10~14Volts(DC) Shutdown o/p voltage, re-power

Current Adjustment Range

3~-25% (Note 4)

Over Current Protection

110~120% rated output power Constant Current limiting,auto recov (Note 3)

Over Temperature Protection

90°C ±10°C (TSW1) Shutdown o/p voltage, re-power

Short Circuit Protection

Hiccup mode, auto recover

Rise Time

1500mS, 150mS/230VAC 3000mS. 150mS/115VAC

Physical Specifications

Size (mm)

145 x 47 x 30 mm

Size (Inches)

5.71” x 1.85” x 1.81”

Weight (g)

220g

Weight (oz)

7.76 oz

Notes

1. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

2. Tolerance : includes set up tolerance, line regulation and load regulation.

3. Please refer to OLP characteristics.

4. Output voltage can be adjusted through the SVR1 on the PCB; limit of output constant current level can be adjusted through the SVR2 on the PCB.

All specifications are typical at nominal input, full load, and 25°C unless otherwise noted

Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.