Order by phone: 1-800-823-8082 / +1-508-964-6300 M-F 8:30am to 5:30pm EST

PLN100 100w Constant Current LED/Lighting Power Supplies

100W Single Output LED Lighting Power Supply

Universal AC input

Protections: Short Circuit/ Overload/ Over voltage/ Over temperature

IP64 design for indoor or outdoor installations

Built-in active Power Factor Correction function

Cooling by free air convection

UL1310 Class 2 power unit

Model Number

DC Voltage Adjust (typ.)

Output Voltage

Output Amps

Ripple and Noise

Over Voltage Protection

Efficiency

PLN100-12

10.2~12Volts(DC)

12 Volts(DC)

5.0 Amps (Note 5)

150mVpk-pk (Note 1)

13~16Volts(DC) Shutdown and latch off o/p voltage, re-power

83%

PLN100-15

12.8~15Volts(DC)

15 Volts(DC)

5.0 Amps (Note 5)

150mVpk-pk (Note 1)

16.5~20Volts(DC) Shutdown and latch off o/p voltage, re-power

85%

PLN100-20

17~20Volts(DC)

20 Volts(DC)

4.8 Amps (Note 5)

150mVpk-pk (Note 1)

22~27Volts(DC) Shutdown and latch off o/p voltage, re-power

87%

PLN100-24

20.4~24Volts(DC)

24 Volts(DC)

4.0 Amps (Note 5)

150mVpk-pk (Note 1)

27~34Volts(DC) Shutdown and latch off o/p voltage, re-power

87%

PLN100-27

23~27Volts(DC)

27 Volts(DC)

3.55 Amps (Note 5)

150mVpk-pk (Note 1)

29~36Volts(DC) Shutdown and latch off o/p voltage, re-power

87%

PLN100-36

30.6~36Volts(DC)

36 Volts(DC)

2.65 Amps (Note 5)

150mVpk-pk (Note 1)

39~48Volts(DC) Shutdown and latch off o/p voltage, re-power

87%

PLN100-48

40.8~48Volts(DC)

48 Volts(DC)

2.0 Amps (Note 5)

200mVpk-pk (Note 1)

52~64Volts(DC) Shutdown and latch off o/p voltage, re-power

87%

PLN100 series

Input Specifications

Input Voltage Range

90-264VAC, 127~370Volts(DC) (Note 4)

Input Current

12Volts(DC) 0.8 Amps/115VAC; 0.4 Amps/230VAC 15Volts(DC) 0.9Amps/115VAC; 0.4Amps/230VAC 20~48Volts(DC) 1.1Amps/115VAC; 0.55Amps/230VAC

Frequency Range

47-63 Hz

Inrush Current

40 Amps @ 230VAC (Cold start)

Leakage Current

< 0.75mA / 240VAC

DC Voltage Adjust (typ.)

10.2~12Volts(DC)

Power Factor Correction

PF> 0.95/ 230VAC; >0.95/ 115VAC ?0.9 at 75~100%load

General Specifications

Isolation

3750VAC Input - Output; 1880VA; Input - Ground; 500VAC Output - Ground

Efficiency

83%

Safety Approvals

UL1310 Class 2, EN61347-1 EN61347-2-13 independent, UL60950-1, UL879 (listed in UL SAM) TUV EN60950-1, CAN/CSA C22.2 No. 223-M91(except for 48V) (Note 8)

Insulation Resistance

?100M?/500 Volts / 25°C / 70%RH

EMI

Compliance to EN55015 EN55022B(CISPR22B)

EMS

Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN55024, EN61547, light industry level (surge 4KV) criteria A

Harmonic Current

Compliance to EN61000-3-2C (>75% load); EN61000-3-3

Environmental Specifications

Operating Temperature

-30°C to +50°C (See Derate Curve)

Storage Temperature

-40°C to +80°C, 10~95% RH

Relative Humidity

20 to +95% RH non cond

MTBF

303.1KHrs min, MIL-HDBK-217F(25°C)

Vibration

10~500Hz, 2G10min./1cycle, period for 72min. each along X, Y, Z axes

Cooling

free air convection

IP Rating

IP64

Temperature Coefficient

±0.03% / °C (0-50°C)

Output Specifications

Output Voltage

12 Volts(DC)

Output Amps

5.0 Amps (Note 5)

Load Regulation

±2%

Line Regulation

±1.0%

Ripple and Noise

150mVpk-pk (Note 1)

Over Voltage Protection

13~16Volts(DC) Shutdown and latch off o/p voltage, re-power

Current Adjustment Range

Can be adjust by internal potential meter SVR2 (Note 6)

Over Current Protection

95~102% Constant current limiting,auto recov

Over Temperature Protection

90°C ±10°C (RTH2) Shutdown o/p voltage, auto recover

Short Circuit Protection

Hiccup mode, auto recover (Note 3)

Hold Up Time

60mS/230VAC; 30mS/115VAC

LED Voltage Operation

Rise Time

1200mS, 80mS / 230VAC & 115VAC

Voltage Tolerance

±3%: 12~27Volts ; ±2%: 36~48Volts (Note 2)

Physical Specifications

Size (mm)

200 x 70.5 x 35 mm

Size (Inches)

7.87”x2.77”x 1.38”)

Weight (g)

520g

Weight (oz)

18.34 oz

Notes

1. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

2. Tolerance : includes set up tolerance, line regulation and load regulation.

3. Please refer to OLP characteristics.

4. Derating may be needed under low input voltage. Please check the derating curve for more details.

5. This is the maximum possible output current and power. Over load protection may be activated slightly below this level to comply with the requirement of UL1310 class 2.

6. Constant current operation region is within 75% ~100% rated output voltage. This is the suitable operation region for LED related applications,

but please

reconfirm special electrical requirements for some specific system design.

8. Safety and EMC design refer to EN60598-1, subject 8750(UL), CNS15233, GB7000.1, FCC part18.

All specifications are typical at nominal input, full load, and 25°C unless otherwise noted

Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.