Order by phone: 1-800-823-8082 / +1-508-964-6300 M-F 8:30am to 5:30pm EST

MV380 MegaVerter DC-DC Converters - High Reliability Watt Power Converters

MV380  MegaVerter DC-DC Converters - High Reliability  Watt  Power Converters

MegaVerter® Series

High Reliability/COTS DC/DC Converters

Full Brick

High Efficiency

-40°C to +100°C Operation Baseplate

Remote Sense

Non-Shutdown, Over Voltage Protection

Parallelable with Current Sharing for n+m Redundancy

Model Number

Watts Input Voltage

Output Voltage

Output Amps

Trim Range Over Voltage protection (Non-Shutdown, Auto Recovery) Efficiency
MV380-26 520 Watt 360-400 Volts (DC)

26vdc

20 Amps

18-30 VDC 30-36 VDC (25°C Case) 88%
MV380-48 600 Watts 345-400 Volts (DC)

48vdc

12.5 Amps

40-51 VDC 54-60 VDC (25°C Case) 91%
MV380-56 600 Watts 360-400 Volts (DC)

56vdc

10.7 Amps

48-60 VDC 66-72 VDC (25°C Case) 91%
MV380-28-700 700 Watt 345-400 Volts (DC)

28vdc

25 Amps

  30-36 VDC (25°C Case) 86%

 

  Multiple Configurations Available
T= -55°C to 100°C Operating Temperature
C= Conformal Coating
RL= No Pure Tin
LF= RoHS Compliant
  (ex. MV380-26-TLF)

MV380 series

Input Specifications

Input Voltage (+In to -In), (Note 1)

380VDC ± 20VDC, (365VDC MV380-28-700) 420VDC max.

Maximum Input Current

2.5A (See Specification Sheet for Input characteristic Curve)

Input Ripple Rejection

60dB @120Hz, typ.

General Specifications

Input/Output Isolation

4500VDC, max.

Input/Baseplat Isolation

2500VDC, max.

Output/Baseplate Isolation

500VDC, max.

Input-to-Output Capacitance

4300pF (Case Floating)

Input-to-Output Resistance

10MΩ, min.

Environmental Specifications

Operating Temperature

-40°C to +100°C

Storage Temperature

-55°C to +125°C

Relative Humidity

20 to +95% RH non cond

Temperature Coefficient

±0.02% / °C (-40 to 100°C)

Output Specifications

Output Voltage

See Selection Chart Above

Load Regulation

0.3% typ., 0.6% max (0 A to Full Load)

Line Regulation

0.02% typ., 0.1% max. (Over Vin Range)

Temperature Coefficient

0.02% /°C max. (-40 to +100°C)

Ripple

1%Vp-p, typ. (5Hz to 20MHz)

Rated Current

12.5A max.

Output Power

See Selection Chart Above

Current Limit

120% F.L. typ. (Vout = 95% Vout nominal)

Short Circuit

150 % F.L. max. (Vout = 250mV)

Transient Response Peak Deviation (0.5 A/µsec slew rate)

5%Vout typ. (Load Change from 25% to 75% to 25% Full Load)

Transient Response Settling Time (0.5A/µsec slew rate)

100µsec, typ. (Vout within 1% Vout nominal)

Efficiency

See Selection Chart Above

Power Sharing Accuracy ±5 %F.L.max. (10 to 100% Full Load)
Trim Range See Selection Chart Above
Remote Sense Compensation 0.5VDC max.
Over voltage Protection (Non-Shutdown, Auto Recovery) See Selection Chart Above
Over Temperature Shut-Down 105°C ± 5°C (Case Temperature)
Turn-On Time 600 msec, typ. (F.L., Vout within 1% of Steady State)
Logic Off Threshold* 0.8V, min. (Vout = 0)
Enable Current (Logic Off)* 1.0 mA, max. (@ Venable = 0V)
Logic On Threshold* 2.4V max.
Turn-On Time* 2.0 msec, max. (F.L., Vout within 1% of Steady State)

Physical Specifications

Size (mm)

12.7 x 60.96 x 116.84 mm

Size (Inches)

0.5”x 2.4”x 4.6”)

Weight (g)

230g

Weight (oz)

7.4 oz

Notes

1. Exceeding absolute maximum ratings may cause permanent damage and may reduce reliability.

All specifications are typical at nominal input, full load, and 25°C unless otherwise noted