Universal AC input |
|
|
Low leakage current ≤ 0.18mA |
|
|
Protections: Short circuit / Overload / Over voltage / Over temperature |
|
|
Fixed switching frequency at 100KHz |
|
|
Free air convection for 140W and forced air convection for 200W |
|
|
UL60601-1 medical safety approved |
MPS200 200 Watt Medical Power Supplies
- Medical Power Supplies: Ten Important Criteria
|
Model Number |
Output Voltage |
Output Amps |
Minimum Load Requirement |
Load Regulation |
Line Regulation |
Ripple and Noise |
Voltage Tolerance |
|
3.3vdc |
40 Amps |
0% |
±1.0% |
±0.5% |
80mV pk-pk (note 1) |
±2.0% |
|
| MPS200-5 | 5vdc | 40 Amps |
0% |
±1.0% |
±0.5% |
80mV pk-pk (note 1) |
±2.0% |
| MPS200-12 | 12vdc | 16.7 Amps |
0% |
±1.0% |
±0.5% |
100mV pk-pk (note 1) |
±2.0% |
| MPS200-15 | 15vdc | 13.4 Amps |
0% |
±1.0% |
±0.5% |
100mV pk-pk (note 1) |
±2.0% |
| MPS200-24 | 24vdc | 8.4 Amps |
0% |
±1.0% |
±0.5% |
150mV pk-pk (note 1) |
±1.0% |
| MPS200-48 | 48vdc | 4.2 Amps |
0% |
±1.0% |
±0.5% |
200mV pk-pk (note 1) |
±1.0% |
MPS200 Single Series
|
Input Specifications
Environmental Specifications
General Specifications
|
Output Specifications
Physical Specifications
Notes 1. Ripple and Noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47 uf parallel capacitor. 2. Tolerance: includes set up tolerance, line regulation and load regulation. All specifications are typical at nominal input, full load, and 25°C unless otherwise noted Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. |