LPV60 60 Watt LED/Lighting Power Supplies
|
Constant voltage design |
|
|
Universal AC input |
|
|
Protections: Short circuit / Overload / Over voltage |
|
|
Epoxy encapsulated with IP67 level |
|
|
Cooling by free air convection |
|
|
Suitable for LED lighting and moving sign applications |
|
Model Number |
Output Voltage |
Output Amps |
Ripple and Noise |
Over Voltage Protection |
Efficiency |
|
5vdc |
8 Amps |
80mV pk-pk (Note 1) |
5.75~6.75vdc Shut down o/p voltage,re-power |
76% |
|
|
12vdc |
5 Amps |
120mV pk-pk (Note 1) |
13.8~16.2vdc Shut down o/p voltage,re-power |
83% |
|
|
15vdc |
4 Amps |
120mV pk-pk (Note 1) |
17.25~20.25vdc Shut down o/p voltage,re-power |
83% |
|
|
24vdc |
2.5 Amps |
150mV pk-pk (Note 1) |
27.6~32.4vdc Shut down o/p voltage,re-power |
86% |
|
|
36vdc |
1.67 Amps |
150mV pk-pk (Note 1) |
41.4~48.6vdc Shut down o/p voltage,re-power |
86% |
|
|
48vdc |
1.25 Amps |
150mV pk-pk (Note 1) |
55.2~64.8vdc Shut down o/p voltage,re-power |
86% |
LPV-60 series
|
Input Specifications
General Specifications
Environmental Specifications
|
Output Specifications
Physical Specifications
Notes 1. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 2. Tolerance : includes set up tolerance, line regulation and load regulation. 3. Derating may be needed under low input voltage. Please check the derating curve for more details. All specifications are typical at nominal input, full load, and 25°C unless otherwise noted Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. |