Model Number

Input Current

Output Voltage

Output Amps

Minimum Load Requirement

Load Regulation

Ripple and Noise

Voltage Tolerance

Over Voltage Protection

Peak Load

DC Voltage Adjust (typ.)

Efficiency

LPS-50-3.3

0.9Amps@ 115VAC / 0.6Amps@ 230VAC

3.3 Volts(DC)

10 Amps

0~12 Amps

±3.0%

50mV pk-pk (note 1)

±3.0%

3.8 ~ 4.45Volt(DC) Hiccup mode, auto recover

39.6W, 10S(Note 3)

3~3.6 Volt(DC)

75%

LPS-50-5

1.2Amps@ 115VAC/ 0.8Amps@ 230VAC

5 Volts(DC)

10 Amps

0~12 Amps

±3.0%

50mV pk-pk (note 1)

±3.0%

5.75 ~ 6.75Volt(DC) Hiccup mode, auto recover

60W, 10S(Note 3)

4.5~5.5 Volt(DC)

81%

LPS-50-12

1.2Amps@ 115VAC/ 0.8Amps@ 230VAC

12 Volts(DC)

4.2 Amps

0~5.0 Amps

±2.0%

80mV pk-pk (note 1)

±2.0%

13.8 ~ 16.2Volt(DC) Hiccup mode, auto recover

60W, 10S(Note 3)

10.8~13.2 Volt(DC)

82%

LPS-50-15

1.2Amps@ 115VAC/ /0.8Amps@ 230VAC

15 Volts(DC)

3.4 Amps

0~4.1 Amps

±2.0%

80mV pk-pk (note 1)

±2.0%

17.25 ~ 20.25Volt(DC) Hiccup mode, auto recover

61.5W, 10S(Note 3)

13.5~16.5 Volt(DC)

84%

LPS-50-24

1.2Amps@ 115VAC/ 0.8Amps@ 230VAC

24 Volts(DC)

2.1 Amps

0~2.5 Amps

±1.0%

80mV pk-pk (note 1)

±1.0%

27.6~ 32.4Volt(DC) Hiccup mode, auto recover

60W, 10S(Note 3)

21.6~27.2 Volt(DC)

85%

LPS-50-48

1.2Amps@ 115VAC/ 0.8Amps@ 230VAC

48 Volts(DC)

1.1 Amps

0~1.3 Amps

±1.0%

100mV pk-pk (note 1)

±1.0%

57.6~ 67.2Volt(DC) Hiccup mode, auto recover

62.4W, 10S(Note 3)

43.2~52.8 Volt(DC)

86%

LPS-50 series

Input Specifications

Input Voltage Range

90 ~ 264 VAC; 127~370 Volts(DC)

Frequency Range

47-63 Hz

Inrush Current

18Amps@115VAC / 35Amps@230VAC (cold start)

Input Current

0.9Amps@115VAC / 0.6Amps@230VAC

Leakage Current

< 1mAmps /240VAC

Harmonic Input Current

Compliance to EN61000-3-2,-3

Environmental Specifications

Operating Temperature

-20°C to +70°C (See Derate Curve)

Storage Temperature

-20°C to +85°C, 10~95% RH

Relative Humidity

20~90% RH non cond

EMI

Compliance to EN55022B (CISPR22B)

MTBF

355KHrs min,MIL-HDBK-217F(25°C)

Vibration

10~500Hz, 2G10min./1cycle, period for 60min. each along X, Y, Z axes

EMS

Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11; ENV50204,EN61000-6-2(EN50082-2) heavy Industry Level, Criteria A

General Specifications

Isolation

3000VAC

Isolation Input-Ground

1500VAC

Isolation Output-Ground

500VAC

Insulation Resistance

≥ 100MΩ / 500Volts(DC)

Efficiency

75%

Safety Approvals

UL60950-1, TUV EN60950-1 Approved

Output Specifications

Output Voltage

3.3 Volts(DC)

Output Amps

10 Amps

Minimum Load Requirement

0~12 Amps

Load Regulation

±3.0%

Line Regulation

±1.0%

Temperature Coefficient

±0.04% / °C (0-50°C)

Ripple and Noise

50mV pk-pk (note 1)

Voltage Tolerance

±3.0%

Over Voltage Protection

3.8 ~ 4.45Volt(DC) Hiccup mode, auto recover

Over Current Protection

122 ~ 160% rated output power Hiccup mode, auto recover

Peak Load

39.6W, 10S(Note 3)

Rise Time

100ms, 40m/230VAC 100mS, 40mS/115VAC

Hold Up Time

70mS/230VAC 12mS/115VAC

Remote shutdown

RC+/RC-: 0~0.8Volts(DC)= power On 4~10Volts(DC)= power Off

DC Voltage Adjust (typ.)

3~3.6Volt(DC)

Physical Specifications

Size (mm)

195 x 55 x 23 mm

Size (Inches)

7.68” x 2.17 ” x 0.91 ”

Weight (g)

240g

Weight (oz)

8.47oz

Notes

1. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

2. Tolerance : includes set up tolerance, line regulation and load regulation.

3. 33.3% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power.

All specifications are typical at nominal input, full load, and 25°C unless otherwise noted

Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.