Universal AC input |
|
|
Protections:Short circuit/Over load/Over voltage |
|
|
Cooling by free air convection |
|
|
Fix switching frequency at 134KHz |
LPS100 100w Power Supplies
|
Model Number |
Output Voltage |
Output Amps |
Minimum Load Requirement |
Load Regulation |
Ripple and Noise |
Voltage Tolerance |
Over Voltage Protection |
DC Voltage Adjust (typ.) |
Efficiency |
|
3.3 Volts(DC) |
20 Amps |
0~20 Amps |
±2.0% |
150mV pk-pk (note 1) |
±3.0% |
3.8 ~ 4.45Volt(DC) Hiccup mode, auto recover |
3~3.6Volt(DC) |
69% |
|
|
5 Volts(DC) |
20 Amps |
0~20 Amps |
±2.0% |
100mV pk-pk (note 1) |
±3.0% |
5.75 ~ 6.75Volt(DC) Hiccup mode, auto recover |
4.5~5.7Volt(DC) |
77% |
|
|
7.5 Volts(DC) |
13.3 Amps |
0~13.3 Amps |
±1.5% |
100mV pk-pk (note 1) |
±2.0% |
9.4 ~ 10.9Volt(DC) Hiccup mode, auto recover |
6~9.0Volt(DC) |
77% |
|
|
12 Volts(DC) |
8.4 Amps |
0~8.4 Amps |
±1.5% |
100mV pk-pk (note 1) |
±2.0% |
13.8 ~ 16.2Volt(DC) Hiccup mode, auto recover |
10~13.2Volt(DC) |
79% |
|
|
13.5 Volts(DC) |
7.5Amps |
0~7.5 Amps |
±1.5% |
100mV pk-pk (note 1) |
±2.0% |
15.5 ~ 18.2Volt(DC) Hiccup mode, auto recover |
12~15Volt(DC) |
79% |
|
|
15 Volts(DC) |
6.7 Amps |
0~6.7 Amps |
±1.5% |
100mV pk-pk (note 1) |
±2.0% |
18 ~ 21Volt(DC) Hiccup mode, auto recover |
13.5~18Volt(DC) |
80% |
|
|
24 Volts(DC) |
4.2 Amps |
0~4.2 Amps(6A 10S) |
±0.5% |
150mV pk-pk (note 1) |
±1.0% |
27.6~ 32.4Volt(DC) Hiccup mode, auto recover |
20~26.4Volt(DC) |
80% |
|
|
27 Volts(DC) |
3.8 Amps |
0~3.8 Amps |
±0.5% |
150mV pk-pk (note 1) |
±1.0% |
33.7 ~ 39.2Volt(DC) Hiccup mode, auto recover |
26~32Volt(DC) |
81% |
|
|
48 Volts(DC) |
2.1 Amps |
0~3.2 Amps |
±0.5% |
200mV pk-pk (note 1) |
±1.0% |
57.6~ 67.2Volt(DC) Hiccup mode, auto recover |
41~56Volt(DC) |
81% |
LPS-100 series
|
Input Specifications
Environmental Specifications
General Specifications
|
Output Specifications
Physical Specifications
Notes 1. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 2. Tolerance : includes set up tolerance, line regulation and load regulation. 3. If the input range 85V-89V, the output load is changed from 0A-rated load, There will be reduced 20V for 1second (LPS-100-24). 4. Mounting holes M1 and M2 should be grounded for EMI purposes. All specifications are typical at nominal input, full load, and 25°C unless otherwise noted Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. |