Order by phone: 1-800-823-8082 / +1-508-964-6300 M-F 8:30am to 5:30pm EST

LPP150 150w Power Supplies

Universal AC input

Protections:Short circuit/Over load/Over voltage

Protections: Over temperature (option)

Built-in active PFC function, PF> 0.96

Cooling by free air convection

Fixed switching frequency at PFC:67KHz PWM:134KHz

Model Number

Output Voltage

Output Amps

Minimum Load Requirement

Load Regulation

Ripple and Noise

Over Voltage Protection

DC Voltage Adjust (typ.)

Efficiency

LPP-150-3.3

3.3 Volts(DC)

30 Amps

0~30 Amps

±1.0%

100mV pk-pk (note 1)

3.63 ~ 4.45Volt(DC) Shut down o/p voltage,re-power

3.14~3.63Volt(DC)

66%

LPP-150-5

5 Volts(DC)

30 Amps

0~30 Amps

±1.0%

100mV pk-pk (note 1)

5.5 ~ 6.75Volt(DC) Shut down o/p voltage,re-power

4.75~5.5Volt(DC)

72%

LPP-150-7.5

7.5 Volts(DC)

20 Amps

0~20 Amps

±1.0%

100mV pk-pk (note 1)

8.25 ~ 10.1Volt(DC) Shut down o/p voltage,re-power

7.13~8.25Volt(DC)

76%

LPP-150-12

12 Volts(DC)

12.5 Amps

0~12.5 Amps

±1.0%

100mV pk-pk (note 1)

13.2~ 16.2Volt(DC) Shut down o/p voltage,re-power

11.4~13.2Volt(DC)

79%

LPP-150-13.5

13.5 Volts(DC)

11.2 Amps

0~11.2 Amps

±1.0%

100mV pk-pk (note 1)

14.85 ~ 18.2Volt(DC) Shut down o/p voltage,re-power

12.8~14.9Volt(DC)

80%

LPP-150-15

15 Volts(DC)

10 Amps

0~10 Amps

±1.0%

100mV pk-pk (note 1)

16.5~ 20.25Volt(DC) Shut down o/p voltage,re-power

14.3~16.5Volt(DC)

80%

LPP-150-24

24 Volts(DC)

6.3 Amps

0~6.3 Amps

±0.5%

150mV pk-pk (note 1)

26.4 ~ 32.4Volt(DC) Shut down o/p voltage,re-power

22.8~26.4Volt(DC)

83%

LPP-150-27

27 Volts(DC)

5.6 Amps

0~5..6 Amps

±0.5%

150mV pk-pk (note 1)

29.7 ~ 36.5Volt(DC) Shut down o/p voltage,re-power

25.7~29.7Volt(DC)

83%

LPP-150-48

48 Volts(DC)

3.2 Amps

0~3.2 Amps

±0.5%

250mV pk-pk (note 1)

52.8 ~ 64.8Volt(DC) Shut down o/p voltage,re-power

45.6~52.8Volt(DC)

83%

LPP-150 series

General Specifications

Input Specifications

Input Voltage Range

90 ~ 264VAC 120~370 Volts(DC) (note 3)

Frequency Range

47-63 Hz

Inrush Current

40Amps / 230VAC

Input Current

2.5 Amps. @ 115VAC, 1.2 Amps. @ 230VAC

Leakage Current

< 3.5mAmps / 240VAC

Power Factor Correction

PF> 0.96 / 230VAC 0.98 / 115VAC

Harmonic Input Current

Compliance to EN61000-3-2,-3

Isolation

3000VAC

Isolation Input-Ground

1500VAC

Isolation Output-Ground

500VAC

Insulation Resistance

? 100M? / 500Volts(DC)

Efficiency

66%

Safety Approvals

UL60950-1, TUV EN60950-1 Approved

Environmental Specifications

Operating Temperature

-10°C to +60°C with cooling FAN

Storage Temperature

-20°C to +85°C, 10~95% RH

Relative Humidity

20~90% RH non cond

EMI

Compliance to EN55022B (CISPR22B)

MTBF

191.8KHrs min,MIL-HDBK-217F(25°C)

Vibration

10~500Hz, 2G10min./1cycle, period for 60min. each along X, Y, Z axes

EMS

Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11; ENV50204, light Industry Level, Criteria A

Output Specifications

Output Voltage

3.3 Volts(DC)

Output Amps

30 Amps

Minimum Load Requirement

0~30 Amps

Load Regulation

±1.0%

Line Regulation

±0.5%

Temperature Coefficient

±0.05% / °C (0-50°C)

Ripple and Noise

100mV pk-pk (note 1)

Voltage Tolerance

±2.0%: 3.3~15Volts(DC), ±1.0%: 24~48Volts(DC) (note 2)

Over Voltage Protection

3.63 ~ 4.45Volt(DC) Shut down o/p voltage,re-power

Over Current Protection

105 ~ 150% rated output power Constant current limiting,auto recover

Rise Time

600ms, 30mS

Hold Up Time

30mS

DC Voltage Adjust (typ.)

3.14~3.63Volt(DC)

Physical Specifications

Size (mm)

222 x 75 x 41 mm

Size (Inches)

8.74” x 2.95 ” x 1.61 ”

Weight (g)

620g

Weight (oz)

21.87oz

Notes

1. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

All specifications are typical at nominal input, full load, and 25°C unless otherwise noted

Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.