Universal AC input |
|
|
Protections:Short circuit/Over load/Over voltage |
|
|
Protections: Over temperature (option) |
|
|
Built-in active PFC function, PF> 0.96 |
|
|
Cooling by free air convection |
|
|
Fixed switching frequency at PFC:67KHz PWM:134KHz |
LPP150 150w Power Supplies
|
Model Number |
Output Voltage |
Output Amps |
Minimum Load Requirement |
Load Regulation |
Ripple and Noise |
Over Voltage Protection |
DC Voltage Adjust (typ.) |
Efficiency |
|
3.3 Volts(DC) |
30 Amps |
0~30 Amps |
±1.0% |
100mV pk-pk (note 1) |
3.63 ~ 4.45Volt(DC) Shut down o/p voltage,re-power |
3.14~3.63Volt(DC) |
66% |
|
|
5 Volts(DC) |
30 Amps |
0~30 Amps |
±1.0% |
100mV pk-pk (note 1) |
5.5 ~ 6.75Volt(DC) Shut down o/p voltage,re-power |
4.75~5.5Volt(DC) |
72% |
|
|
7.5 Volts(DC) |
20 Amps |
0~20 Amps |
±1.0% |
100mV pk-pk (note 1) |
8.25 ~ 10.1Volt(DC) Shut down o/p voltage,re-power |
7.13~8.25Volt(DC) |
76% |
|
|
12 Volts(DC) |
12.5 Amps |
0~12.5 Amps |
±1.0% |
100mV pk-pk (note 1) |
13.2~ 16.2Volt(DC) Shut down o/p voltage,re-power |
11.4~13.2Volt(DC) |
79% |
|
|
13.5 Volts(DC) |
11.2 Amps |
0~11.2 Amps |
±1.0% |
100mV pk-pk (note 1) |
14.85 ~ 18.2Volt(DC) Shut down o/p voltage,re-power |
12.8~14.9Volt(DC) |
80% |
|
|
15 Volts(DC) |
10 Amps |
0~10 Amps |
±1.0% |
100mV pk-pk (note 1) |
16.5~ 20.25Volt(DC) Shut down o/p voltage,re-power |
14.3~16.5Volt(DC) |
80% |
|
|
24 Volts(DC) |
6.3 Amps |
0~6.3 Amps |
±0.5% |
150mV pk-pk (note 1) |
26.4 ~ 32.4Volt(DC) Shut down o/p voltage,re-power |
22.8~26.4Volt(DC) |
83% |
|
|
27 Volts(DC) |
5.6 Amps |
0~5..6 Amps |
±0.5% |
150mV pk-pk (note 1) |
29.7 ~ 36.5Volt(DC) Shut down o/p voltage,re-power |
25.7~29.7Volt(DC) |
83% |
|
|
48 Volts(DC) |
3.2 Amps |
0~3.2 Amps |
±0.5% |
250mV pk-pk (note 1) |
52.8 ~ 64.8Volt(DC) Shut down o/p voltage,re-power |
45.6~52.8Volt(DC) |
83% |
LPP-150 series
|
General Specifications Input Specifications
Environmental Specifications
|
Output Specifications
Physical Specifications
Notes 1. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. All specifications are typical at nominal input, full load, and 25°C unless otherwise noted Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. |