Model Number

Output Voltage

Output Amps

Minimum Load Requirement

Load Regulation

Ripple and Noise

Voltage Tolerance

Over Voltage Protection

DC Voltage Adjust (typ.)

Efficiency

LPP-100-3.3

3.3 Volts(DC)

20 Amps

0~20 Amps

±1.0%

100mV pk-pk (note 1)

±2.0% (note 2)

3.8 ~ 4.45Volt(DC) Shut down o/p voltage,re-power

3.14~3.63Volt(DC)

69%

LPP-100-5

5 Volts(DC)

20 Amps

0~20 Amps

±1.0%

100mV pk-pk (note 1)

±2.0% (note 2)

5.75 ~ 6.75Volt(DC) Shut down o/p voltage,re-power

4.75~5.5Volt(DC)

75%

LPP-100-7.5

7.5 Volts(DC)

13.5 Amps

0~13.3 Amps

±1.0%

100mV pk-pk (note 1)

±2.0% (note 2)

8.6 ~ 10.1Volt(DC) Shut down o/p voltage,re-power

7.13~8.25Volt(DC)

76%

LPP-100-12

12 Volts(DC)

8.5 Amps

0~8.5 Amps

±0.5%

100mV pk-pk (note 1)

±2.0% (note 2)

13.8 ~ 16.2Volt(DC) Shut down o/p voltage,re-power

11.4~13.2Volt(DC)

79%

LPP-100-13.5

13.5 Volts(DC)

7.5 Amps

0~7.5 Amps

±0.5%

100mV pk-pk (note 1)

±2.0% (note 2)

15.5 ~ 18.2Volt(DC) Shut down o/p voltage,re-power

12.8~14.9Volt(DC)

79%

LPP-100-15

15 Volts(DC)

6.7 Amps

0~6.7 Amps

±0.5%

100mV pk-pk (note 1)

±2.0% (note 2)

17.25~ 20.25Volt(DC) Shut down o/p voltage,re-power

14.3~16.5Volt(DC)

80%

LPP-100-24

24 Volts(DC)

4.2 Amps

0~4.2 Amps

±0.5%

100mV pk-pk (note 1)

±1.0% (note 2)

27.6 ~ 32.4Volt(DC) Shut down o/p voltage,re-power

22.8~26.4Volt(DC)

83%

LPP-100-27

27 Volts(DC)

3.8 Amps

0~3.8 Amps

±0.5%

150mV pk-pk (note 1)

±1.0% (note 2)

31 ~ 36.45Volt(DC) Shut down o/p voltage,re-power

25.7~29.7Volt(DC)

83%

LPP-100-48

48 Volts(DC)

2.1 Amps

0~2.1 Amps

±0.5%

250mV pk-pk (note 1)

±1.0% (note 2)

55.2 ~ 64.8Volt(DC) Shut down o/p voltage,re-power

45.6~52.8Volt(DC)

83%

LPP-100 series

Input Specifications

Environmental Specifications

Operating Temperature

-10°C to +60°C (See Derate Curve)

Storage Temperature

-20°C to +85°C, 10~95% RH

Relative Humidity

20~90% RH non cond

EMI

Compliance to EN55022B (CISPR22B)

MTBF

224.3KHrs min,MIL-HDBK-217F(25°C)

Vibration

10~500Hz, 2G10min./1cycle, period for 60min. each along X, Y, Z axes

General Specifications

Input Voltage Range

90 ~ 264VAC 120~370 Volts(DC)

Frequency Range

47-63 Hz

Inrush Current

30Amps / 230VAC (cold start)

Input Current

1.7 Amps. @ 115VAC; 0.75 Amps. @ 230VAC

Leakage Current

< 2mAmps / 240VAC

Power Factor Correction

PF> 0.95 / 230VAC 0.98 / 115VAC

Harmonic Input Current

Compliance to EN61000-3-2,-3

Isolation

3000VAC

Isolation Input-Ground

1500VAC

Isolation Output-Ground

500VAC

Insulation Resistance

? 100M? / 500Volts(DC)

Efficiency

69%

Safety Approvals

UL60950-1, TUV EN60950-1 Approved

Output Specifications

Output Voltage

3.3 Volts(DC)

Output Amps

20 Amps

Minimum Load Requirement

0~20 Amps

Load Regulation

±1.0%

Line Regulation

±0.5%

Temperature Coefficient

±0.05% / °C (0-50°C)

Ripple and Noise

100mV pk-pk (note 1)

Voltage Tolerance

±2.0% (note 2)

Over Voltage Protection

3.8 ~ 4.45Volt(DC) Shut down o/p voltage,re-power

Over Current Protection

105 ~ 150% rated output power, Constant current limiting,auto recover

Rise Time

600ms, 30mS/ 230VAC, 1200ms, 30mS/115VAC

Hold Up Time

28mS /230VAC; 28mS/115VAC

DC Voltage Adjust (typ.)

3.14~3.63Volt(DC)

Physical Specifications

Size (mm)

222 x 62 x 32 mm

Size (Inches)

8.74” x 2.44 ” x 1.26 ”

Weight (g)

510g

Weight (oz)

17.99 oz

Notes

1. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

2. Tolerance : includes set up tolerance, line regulation and load regulation.

3. Derating may be needed under low input voltages. Please check the derating curve for more details.

All specifications are typical at nominal input, full load, and 25°C unless otherwise noted

Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.