HLG240 240 Watt Constant Current LED/Lighting Power Supplies
|
Universal AC input up to 305VAC |
|
|
Active Power Factor Correction |
|
|
OCP Point Adjustable Through Output Cable or Internal Potential Meter |
|
|
Suitable for LED Lighting and Moving Sign Applications |
|
All-Round Protection: OVP, SCP, OLP, OTP |
|
|
IP65 / IP67 Design for Indoor or Outdoor Installations |
|
|
Compliance with Worldwide Safety & EMC Regulations |
|
Model Number |
Output Voltage |
Output Amps |
Over Voltage Protection |
DC Voltage Adjust | Constant Current Region | Load Regulation | Ripple/Noise Max. | Voltage Tolerance |
Current Adjust |
Efficiency |
|
12 Volts (DC) |
16 Amps |
13.5vdc Latch mode. The power supply shall return to normal operation only after the power is turn-on again |
11.2 ~ 12.8 Volts (DC) | 6 ~ 12Volts | ± 2% |
150 mVpk-pk | ± 2.5% |
8 ~ 16 Amps |
90% |
|
15 Volts (DC) |
15 Amps |
16.5vdc Latch mode. The power supply shall return to normal operation only after the power is turn-on again |
14 ~ 16 Volts (DC) | 7.5 ~ 15 Volts | ± 1.5% | 150 mVpk-pk | ± 2% | 7.5 ~ 15 Amps |
90% |
|
|
20 Volts (DC) |
12 Amps |
22vdc Latch mode. The power supply shall return to normal operation only after the power is turn-on again |
18.6 ~ 21.4 Volts (DC) | 10 ~ 20 Volts | ± 1% | 150 mVpk-pk | ± 1% |
6 ~ 12 Amps |
92% |
|
|
24 Volts (DC) |
10Amps |
26vdc Latch mode. The power supply shall return to normal operation only after the power is turn-on again |
22.4 ~ 25.6 Volts (DC) | 12 ~ 24 Volts | ± 0.5% | 200 mVpk-pk | ± 1% |
5 ~ 10 Amps |
93% |
|
|
30 Volts (DC) |
8 Amps |
32.5vdc Latch mode. The power supply shall return to normal operation only after the power is turn-on again |
28 ~ 32 Volts (DC) | 15 ~ 30 Volts | ± 0.5% | 250 mVpk-pk | ± 1% |
4 ~ 8 Amps |
93% |
|
|
36 Volts (DC) |
6.7 Amps |
40vdc Latch mode. The power supply shall return to normal operation only after the power is turn-on again |
33.5 ~ 38.5 Volts (DC) | 18 ~ 36 Volts | ± 0.5% | 250 mVpk-pk | ± 1% |
3.3 ~ 6.7 Amps |
93% |
|
|
42 Volts (DC) |
5.72 Amps |
46vdc Latch mode. The power supply shall return to normal operation only after the power is turn-on again |
39 ~ 45 Volts (DC) | 21 ~ 42 Volts | ± 0.5% | 250 mVpk-pk | ± 1% |
2.86 ~ 5.72 Amps |
94% |
|
|
48 Volts (DC) |
5 Amps |
53vdc Latch mode. The power supply shall return to normal operation only after the power is turn-on again |
44.8 ~ 51.2 Volts (DC) | 24 ~ 48 Volts | ± 0.5% | 250 mVpk-pk | ± 1% |
2.5 ~ 5 Amps |
93.5% |
|
54 Volts (DC) |
4.45 Amps |
59vdc Latch mode. The power supply shall return to normal operation only after the power is turn-on again |
50 ~ 57 Volts (DC) | 27 ~ 54 Volts | ± 0.5% | 350 mVpk-pk | ± 1% | 2.23 ~ 4.45 Amps |
94% |
|
* Guide to part selection: Blank: IP67 rated, Cable for I/O connection. (Optional) A: IP65 rated. Output voltage and constant current level can be adjusted through internal potential meter. B: IP67 rated. Constant current level adjustable through output cable. (Optional) C: Terminal block for I/O connection. Output voltage and constant current level can be adjusted through internal potential meter. (Optional) |
||||||||||
HLG240 series
|
Input Specifications
General Specifications
Environmental Specifications
|
Output Specifications
Physical Specifications
Notes All specifications are typical at nominal input, full load, and 25°C unless otherwise noted. 1. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 2. Tolerance: includes set up tolerance, line regulation and load regulation. 3. Constant current operation region is within 50% ~ 100% rated output voltage. This is the suitable operation region for LED related applications, but please reconfirm special electrical requirements for some specific system design. 4. Derating may be needed under low input voltages. Please check the derating curve for more details. 5. Type A and Type C only. 6. Please refer to derating curve. 7. Please refer to OCP characteristics. 8. Safety and EMC design refer to EN60598-1, subject 8750(UL), CNS15233, GB7000.1, FCC part 18. Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. |