FEC40 40 Watt Converters
|
Wide 2 : 1 Input Range |
|
|
High Efficiency |
|
|
Regulated Outputs |
|
|
1600V Isolation |
|
|
Full EMI Shielding |
|
|
L-C Type Input Filter |
|
Model Number |
Input Voltage Range |
Input Surge Voltage |
Under Voltage Lockout |
Minimum Load Requirement |
Output Voltage |
Output Amps |
Load Regulation |
Line Regulation |
|
18-36 VDC |
50mS max. 50VDC |
DC-DC On: 17.8V / DC-DC Off : 16V |
3.3 VDC |
8 |
±0.5% 10% - FL (Note 3) |
±0.5% |
||
|
36-75 VDC |
100mS max. 100VDC |
DC-DC On: 36V / DC-DC Off: 34V |
3.3 VDC |
8 |
±0.5% 10% - FL (Note 3) |
±0.5% |
||
|
18-36 VDC |
50mS max. 50VDC |
DC-DC On: 17.8V / DC-DC Off : 16V |
5 VDC |
8 |
±0.5% 10% - FL (Note 3) |
±0.5% |
||
|
36-75 VDC |
100mS max. 100VDC |
DC-DC On: 36V / DC-DC Off: 34V |
5 VDC |
8 |
±0.5% 10% - FL (Note 3) |
±0.5% |
||
|
18-36 VDC |
50mS max. 50VDC |
DC-DC On: 17.8V / DC-DC Off : 16V |
12 VDC |
3.33 |
±0.5% 10% - FL (Note 3) |
±0.5% |
||
|
36-75 VDC |
100mS max. 100VDC |
DC-DC On: 36V / DC-DC Off: 34V |
12 VDC |
3.33 |
±0.5% 10% - FL (Note 3) |
±0.5% |
||
|
18-36 VDC |
50mS max. 50VDC |
DC-DC On: 17.8V / DC-DC Off : 16V |
15 VDC |
2.66 |
±0.5% 10% - FL (Note 3) |
±0.5% |
||
|
36-75 VDC |
100mS max. 100VDC |
DC-DC On: 36V / DC-DC Off: 34V |
15 VDC |
2.66 |
±0.5% 10% - FL (Note 3) |
±0.5% |
||
|
18-36 VDC |
50mS max. 50VDC |
DC-DC On: 17.8V / DC-DC Off : 16V |
3.3 / 5 VDC |
4 / 4 |
±1% 10% - FL (Note 3) |
±0.5% |
||
|
36-75 VDC |
100mS max. 100VDC |
DC-DC On: 36V / DC-DC Off: 34V |
3.3 / 5 VDC |
4 / 4 |
±1% 10% - FL (Note 3) |
±0.5% |
||
|
18-36 VDC |
50mS max. 50VDC |
DC-DC On: 17.8V / DC-DC Off : 16V |
10% (Note 2) |
3.3, ±12 VDC |
6, ±0.40 |
±3%, ±5% 10% - FL (Note 3) |
±1%, ±5% |
|
|
36-75 VDC |
100mS max. 100VDC |
DC-DC On: 36V / DC-DC Off: 34V |
10% (Note 2) |
3.3, ±12 VDC |
6, ±0.40 |
±3%, ±5% 10% - FL (Note 3) |
±1%, ±5% |
|
|
18-36 VDC |
50mS max. 50VDC |
DC-DC On: 17.8V / DC-DC Off : 16V |
10% (Note 2) |
3.3, ±15 VDC |
6, ±0.30 |
±3%, ±5% 10% - FL (Note 3) |
±1%, ±5% |
|
|
36-75 VDC |
100mS max. 100VDC |
DC-DC On: 36V / DC-DC Off: 34V |
10% (Note 2) |
3.3, ±15 VDC |
6, ±0.30 |
±3%, ±5% 10% - FL (Note 3) |
±1%, ±5% |
|
|
18-36 VDC |
50mS max. 50VDC |
DC-DC On: 17.8V / DC-DC Off : 16V |
10% (Note 2) |
5, ±12 VDC |
6, ±0.40 |
±3%, ±5% 10% - FL (Note 3) |
±1%, ±5% |
|
|
36-75 VDC |
100mS max. 100VDC |
DC-DC On: 36V / DC-DC Off: 34V |
10% (Note 2) |
5, ±12 VDC |
6, ±0.40 |
±3%, ±5% 10% - FL (Note 3) |
±1%, ±5% |
|
|
18-36 VDC |
50mS max. 50VDC |
DC-DC On: 17.8V / DC-DC Off : 16V |
10% (Note 2) |
5, ±15 VDC |
6, ±0.30 |
±3%, ±5% 10% - FL (Note 3) |
±1%, ±5% |
|
|
36-75 VDC |
100mS max. 100VDC |
DC-DC On: 36V / DC-DC Off: 34V |
10% (Note 2) |
5, ±15 VDC |
6, ±0.30 |
±3%, ±5% 10% - FL (Note 3) |
±1%, ±5% |
FEC40 series
|
Model Number |
Cross Regulation |
Preset Accuracy |
Ripple and Noise |
Over Voltage Protection |
Efficiency |
|
|
±1% (FL &513:513Nom I/P) |
50mV Pk-Pk (Note 5) |
±2% |
3.9Volts Zener Diode Clamp |
87% |
||
|
±1% (FL &513:513Nom I/P) |
50mV Pk-Pk (Note 5) |
±2% |
3.9Volts Zener Diode Clamp |
88% |
||
|
±1% (FL &513:513Nom I/P) |
50mV Pk-Pk (Note 5) |
±2% |
6.2Volts Zener Diode Clamp |
89% |
||
|
±1% (FL &513:513Nom I/P) |
50mV Pk-Pk (Note 5) |
±2% |
6.2Volts Zener Diode Clamp |
90% |
||
|
±1% (FL &513:513Nom I/P) |
75mV Pk-Pk (Note 5) |
±2% |
15 Volts Zener Diode Clamp |
88% |
||
|
±1% (FL &513:513Nom I/P) |
75mV Pk-Pk (Note 5) |
±2% |
15 Volts Zener Diode Clamp |
89% |
||
|
±1% (FL &513:513Nom I/P) |
75mV Pk-Pk (Note 5) |
±2% |
18Volts Zener Diode Clamp |
89% |
||
|
±1% (FL &513:513Nom I/P) |
75mV Pk-Pk (Note 5) |
±2% |
18Volts Zener Diode Clamp |
89% |
||
|
±1% (Note 4) |
±1% (FL &513:513Nom I/P) |
100mV Pk-Pk (Note 5) |
±2% |
3.9 Volts |
84% |
|
|
±1% (Note 4) |
±1% (FL &513:513Nom I/P) |
100mV Pk-Pk (Note 5) |
±2% |
3.9 Volts |
85% |
|
|
±5% (Note 4) |
±1%, ±3% (FL &513:513Nom I/P) |
50 / 75mV Pk-Pk (Note 5) |
±2%, ±5% |
3.9 Volts |
85% |
|
|
±5% (Note 4) |
±1%, ±3% (FL &513:513Nom I/P) |
50 / 75mV Pk-Pk (Note 5) |
±2%, ±5% |
3.9 Volts |
86% |
|
|
±5% (Note 4) |
±1%, ±3% (FL &513:513Nom I/P) |
50 / 75mV Pk-Pk (Note 5) |
±2%, ±5% |
3.9 Volts |
85% |
|
|
±5% (Note 4) |
±1%, ±3% (FL &513:513Nom I/P) |
50 / 75mV Pk-Pk (Note 5) |
±2%, ±5% |
3.9 Volts |
86% |
|
|
±5% (Note 4) |
±1%, ±3% (FL &513:513Nom I/P) |
50 / 75mV Pk-Pk (Note 5) |
±2%, ±5% |
3.9 Volts |
87% |
|
|
±5% (Note 4) |
±1%, ±3% (FL &513:513Nom I/P) |
50 / 75mV Pk-Pk (Note 5) |
±2%, ±5% |
3.9 Volts |
88% |
|
|
±5% (Note 4) |
±1%, ±3% (FL &513:513Nom I/P) |
50 / 75mV Pk-Pk (Note 5) |
±2%, ±5% |
3.9 Volts |
87% |
|
|
±5% (Note 4) |
±1%, ±3% (FL &513:513Nom I/P) |
50 / 75mV Pk-Pk (Note 5) |
±2%, ±5% |
3.9 Volts |
88% |
|
Input Specifications
General Specifications
Physical Specifications
Notes 1. Maximum output deviation is 10% inclusive of remote sense and him. If remote sense is not being used, the +Vsense should be connected to its corresponding+OUTPUT and likewise the sense should be connected to its corresponding -OUTPUT. 2. Triple outputs requires a minimum 10% loading on the output to maintain specified regulation. Operation under no-load condition will not damage these devices, however they may not meet all listed specifications. 3. Load regulation for triple output: Main output (V1): 10 to 100% with 10% to 100% balanced on auxiliaries. All specifications are typical at nominal input, full load, and 25°C unless otherwise noted Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. |
Output Specifications
Environmental Specifications
|