Isolated and Regulated 10 WATT Modular DC/DC Converters
FDC10 10w Power Supplies
|
Wide 2 : 1 Input Range |
|
|
High Efficiency |
|
|
Regulated Outputs |
|
|
1600V Isolation |
|
|
Full EMI Shielding |
|
|
Standard Pinouts |
|
Model Number |
Input Voltage Range |
Output Voltage |
Output Amps |
Load Regulation |
Ripple and Noise |
Voltage Balance |
Over Voltage Protection |
|
9-18 VDC |
3.3 VDC |
2 |
±1% |
50mV Pk-Pk, typ |
3.9Volts |
||
|
18-36 VDC |
3.3 VDC |
2 |
±1% |
50mV Pk-Pk, typ |
3.9Volts |
||
|
36-72 VDC |
3.3 VDC |
2 |
±1% |
50mV Pk-Pk, typ |
3.9Volts |
||
|
9-18 VDC |
5 VDC |
2 |
±1% |
50mV Pk-Pk, typ |
6.2Volts |
||
|
18-36 VDC |
5 VDC |
2 |
±1% |
50mV Pk-Pk, typ |
6.2Volts |
||
|
36-72 VDC |
5 VDC |
2 |
±1% |
50mV Pk-Pk, typ |
6.2Volts |
||
|
9-18 VDC |
12 VDC |
0.83 |
±1% |
50mV Pk-Pk, typ |
15Volts |
||
|
18-36 VDC |
12 VDC |
0.83 |
±1% |
50mV Pk-Pk, typ |
15Volts |
||
|
36-72 VDC |
12 VDC |
0.83 |
±1% |
50mV Pk-Pk, typ |
15Volts |
||
|
9-18 VDC |
15 VDC |
0.67 |
±1% |
50mV Pk-Pk, typ |
18Volts |
||
|
18-36 VDC |
15 VDC |
0.67 |
±1% |
50mV Pk-Pk, typ |
18Volts |
||
|
36-72 VDC |
15 VDC |
0.67 |
±1% |
50mV Pk-Pk, typ |
18Volts |
||
|
9-18 VDC |
±5 VDC |
±1 |
±2% 10% - FL |
75mV Pk-Pk, typ |
±1% |
6.2Volts |
|
|
18-36 VDC |
±5 VDC |
±1 |
±2% 10% - FL |
75mV Pk-Pk, typ |
±1% |
6.2Volts |
|
|
36-72 VDC |
±5 VDC |
±1 |
±2% 10% - FL |
75mV Pk-Pk, typ |
±1% |
6.2Volts |
|
|
9-18 VDC |
±12 VDC |
±0.416 |
±2% 10% - FL |
75mV Pk-Pk, typ |
±1% |
15Volts |
|
|
18-36 VDC |
±12 VDC |
±0.416 |
±2% 10% - FL |
75mV Pk-Pk, typ |
±1% |
15Volts |
|
|
36-72 VDC |
±12 VDC |
±0.416 |
±2% 10% - FL |
75mV Pk-Pk, typ |
±1% |
15Volts |
|
|
9-18 VDC |
±15 VDC |
±0.333 |
±2% 10% - FL |
75mV Pk-Pk, typ |
±1% |
18Volts |
|
|
18-36 VDC |
±15 VDC |
±0.333 |
±2% 10% - FL |
75mV Pk-Pk, typ |
±1% |
18Volts |
|
|
36-72 VDC |
±15 VDC |
±0.333 |
±2% 10% - FL |
75mV Pk-Pk, typ |
±1% |
18Volts |
FDC10 series
|
Input Specifications
General Specifications
Physical Specifications
|
Output Specifications
Environmental Specifications
Notes All specifications are typical at nominal input, full load, and 25°C unless otherwise noted Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. |