ELP75 75w Constant Current LED/Lighting Power Supplies

|
High Efficiency (Up to 92%) |
|
|
Active Power Factor Correction (typ 0.99) |
|
|
Constant Output Current |
|
|
Waterproof (IP67) |
|
|
All-Round Protection: OVP, SCP, OTP |
|
|
Comply with UL8750 & EN61347 Safety Regulations |
|
Model Number |
Output Voltage |
Output Amps |
Over Voltage Protection |
Efficiency |
|
214 Volts(DC) |
0.35Amps |
250 Volts(DC) Latch mode. The power supply shall return to normal operation only after the power is turn-on again |
92% |
|
|
166 Volts(DC) |
0.45Amps |
200 Volts(DC) Latch mode. The power supply shall return to normal operation only after the power is turn-on again |
92% |
|
|
108 Volts(DC) |
0.7Amps |
130 Volts(DC) Latch mode. The power supply shall return to normal operation only after the power is turn-on again |
91% |
|
|
72Volts(DC) |
1.05Amps |
85 Volts(DC) Latch mode. The power supply shall return to normal operation only after the power is turn-on again |
90% |
|
|
54 Volts(DC) |
1.4 Amps |
65 Volts(DC) Latch mode. The power supply shall return to normal operation only after the power is turn-on again |
90% |
|
|
36 Volts(DC) |
2.1 Amps |
48 Volts(DC) Latch mode. The power supply shall return to normal operation only after the power is turn-on again |
89% |
|
|
27 Volts(DC) |
2.8 Amps |
35 Volts(DC) Latch mode. The power supply shall return to normal operation only after the power is turn-on again |
89% |
|
|
20 Volts(DC) |
3.75 Amps |
26 Volts(DC) Latch mode. The power supply shall return to normal operation only after the power is turn-on again |
88% |
|
|
15 Volts(DC) |
5.0 Amps |
20 Volts(DC) Latch mode. The power supply shall return to normal operation only after the power is turn-on again |
88% |
ELP75 series
|
Input Specifications
General Specifications
Environmental Specifications
|
Output Specifications
Physical Specifications
Notes All specifications are typical at nominal input, full load, and 25°C unless otherwise noted Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. |