ELP40 40 Watt Constant Current LED/Lighting Power Supplies

40W LED Driver

High Efficiency (Up to 88%)

Active Power Factor Correction (typ 0.94)

Constant Output Current

Waterproof (IP66)

All-Round Protection: OVP, SCP, OLP

Comply with UL1310 & EN61347-1 Regulations

Optional Dimmer Control Feature

Lightning Protection

Model Number

Output Voltage

Output Amps

Over Voltage Protection

Efficiency

ELP40-1211D

ELP40-1211P

11vdc

3.497 Amps

15vdc Latch mode. The power supply shall return to normal operation only after the power is turn-on again

84%

ELP40-1216D

ELP40-1216P

16vdc

2.331 Amps

21vdc Latch mode. The power supply shall return to normal operation only after the power is turn-on again

85%

ELP40-1223D

ELP40-1223P

23vdc

1.743 Amps

28vdc Latch mode. The power supply shall return to normal operation only after the power is turn-on again

86%

ELP40-1225D

ELP40-1225P

25vdc

1.47 Amps

31vdc Latch mode. The power supply shall return to normal operation only after the power is turn-on again

87%

ELP40-1229D

ELP40-1229P

29vdc

1.344 Amps

31vdc Latch mode. The power supply shall return to normal operation only after the power is turn-on again

87%

ELP40-1236D

ELP40-1236P

36vdc

1.103 Amps

38vdc Latch mode. The power supply shall return to normal operation only after the power is turn-on again

87%

ELP40-1254D

ELP40-1254P

54vdc 0.735 Amps 59vdc Latch mode. The power supply shall return to normal operation only after the power is turn-on again 87%

ELP40-1289D

ELP40-1289P

89vdc 0.473 Amps 95vdc Latch mode. The power supply shall return to normal operation only after the power is turn-on again 88%

ELP40-12114D

ELP40-12114P

114Volts(DC) 0.368 Amps 124vdc Latch mode. The power supply shall return to normal operation only after the power is turn-on again 89%
*Note: (D) denotes choice of receiving this product WITH a Dimmer control Feature. (P) denotes the choice of receiving this product WITHOUT the Dimmer Control Feature.

ELP40 series

Input Specifications

Input Voltage Range

90-305VAC

Input Current

0.48 Amps max @ 100VAC; 0.23 Amps max @ 220VAC

Frequency Range

47-63 Hz

General Specifications

Efficiency

See Selection Chart Above

Safety Approvals

USA & Canada UL8750 Compliance to UL1310 Class 2, UL1012, UL935, CAN/CSA C22.2 No. 0, CSA-C22.2 No. 107.1, CSA-C22.2 No. 250.0; CE Europe EN61347-1, EN61347-2-13

EMI

EN55015

EMS

Compliance to EN61000-4-2,3,4,6,8,11; EN61000-3-2,3 EN61547

No Load Power Consumption

≤6.0W

Environmental Specifications

Operating Temperature

-20°C to + 70°C 10~100% RH (See Derate Curve)

Storage Temperature

-40°C to +85°C, 5~100% RH

MTBF

487 KHrs min @ 80% load, MIL-HDBK-217F (25°C) / 110VAC

Life Time

77,000 Hrs; 110VAC, 45°C, 80% Load

IP Rating

IP66

Output Specifications

Output Voltage

See Selection Chart Above

Output Amps

See Selection Chart Above

Load Regulation

5.0%

Line Regulation

2.0%

Ripple and Noise

10% pk-pk / 20MHz bandwidth, 0.1uF ceramic capacitor 10uF eletrolytic capacitor

Turn-on Delay Time

1.7S @ 110VAC

Overshoot

10% When power on or off

Undershoot

10% When power on or off

Over Voltage Protection

See Selection Chart Above

Short Circuit Protection

No damage shall occur when any output operating in a short circuit condition. The power supply shall be self-recovery when the fault condition is removed

Physical Specifications

Size (mm)

95 x 70 x 32 mm

Size (Inches)

3.74” x 2.76” x 1.26”

Weight (g)

300g

Weight (oz)

10.58 oz

Notes

All specifications are typical at nominal input, full load, and 25°C unless otherwise noted

11-36 Volt outputs are Class 2 U.S. and Canada; The 54 Volt output is Class 2 U.S. only; All others are NOT Class 2.

Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.