ELP40 40 Watt Constant Current LED/Lighting Power Supplies
|
High Efficiency (Up to 88%) |
|
|
Active Power Factor Correction (typ 0.94) |
|
|
Constant Output Current |
|
|
Waterproof (IP66) |
|
|
All-Round Protection: OVP, SCP, OLP |
|
Comply with UL1310 & EN61347-1 Regulations |
|
Optional Dimmer Control Feature |
|
Lightning Protection |
|
Model Number |
Output Voltage |
Output Amps |
Over Voltage Protection |
Efficiency |
|
11vdc |
3.497 Amps |
15vdc Latch mode. The power supply shall return to normal operation only after the power is turn-on again |
84% |
|
|
16vdc |
2.331 Amps |
21vdc Latch mode. The power supply shall return to normal operation only after the power is turn-on again |
85% |
|
|
23vdc |
1.743 Amps |
28vdc Latch mode. The power supply shall return to normal operation only after the power is turn-on again |
86% |
|
|
25vdc |
1.47 Amps |
31vdc Latch mode. The power supply shall return to normal operation only after the power is turn-on again |
87% |
|
|
29vdc |
1.344 Amps |
31vdc Latch mode. The power supply shall return to normal operation only after the power is turn-on again |
87% |
|
|
36vdc |
1.103 Amps |
38vdc Latch mode. The power supply shall return to normal operation only after the power is turn-on again |
87% |
|
| 54vdc | 0.735 Amps | 59vdc Latch mode. The power supply shall return to normal operation only after the power is turn-on again | 87% | |
| 89vdc | 0.473 Amps | 95vdc Latch mode. The power supply shall return to normal operation only after the power is turn-on again | 88% | |
| 114Volts(DC) | 0.368 Amps | 124vdc Latch mode. The power supply shall return to normal operation only after the power is turn-on again | 89% | |
| *Note: (D) denotes choice of receiving this product WITH a Dimmer control Feature. (P) denotes the choice of receiving this product WITHOUT the Dimmer Control Feature. | ||||
ELP40 series
|
Input Specifications
General Specifications
Environmental Specifications
|
Output Specifications
Physical Specifications
Notes All specifications are typical at nominal input, full load, and 25°C unless otherwise noted 11-36 Volt outputs are Class 2 U.S. and Canada; The 54 Volt output is Class 2 U.S. only; All others are NOT Class 2. Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. |