ELP120 120 Watt Constant Current Power Supplies
|
Ultra High Efficiency (Up to 92%) |
|
|
Active Power Factor Correction (typ 0.99) |
|
|
Constant Output Current |
|
|
Waterproof (IP67) |
|
|
All-Round Protection: OVP, SCP, OTP |
|
|
Complies with Worldwide Safety & EMC Regulations |
|
| Lightning Protection |
|
Model Number |
Output Voltage |
Output Amps |
Over Voltage Protection |
Efficiency |
| 24 Volts (DC) |
4.9 Amps |
28vdc Latch mode. The power supply shall return to normal operation only after the power is turned on again |
90.5% |
|
| ELP120-1228 | 28 Volts (DC) | 4.2 Amps |
33vdc Latch mode. The power supply shall return to normal operation only after the power is turned on again |
90.5% |
| ELP120-1234 | 34 Volts (DC) |
3.5 Amps |
40vdc Latch mode. The power supply shall return to normal operation only after the power is turned on again |
90.5% |
| ELP120-1238 | 38 Volts (DC) |
3.15 Amps |
45vdc Latch mode. The power supply shall return to normal operation only after the power is turned on again |
90.5% |
| ELP120-1243 | 43 Volts (DC) |
2.8 Amps |
51vdc Latch mode. The power supply shall return to normal operation only after the power is turned on again |
91% |
| ELP120-1249 | 49 Volts (DC) |
2.45 Amps |
58vdc Latch mode. The power supply shall return to normal operation only after the power is turned on again |
91% |
| ELP120-1257 | 57 Volts (DC) |
2.1 Amps |
68vdc Latch mode. The power supply shall return to normal operation only after the power is turned on again |
91% |
| ELP120-1268 | 68 Volts (DC) |
1.75 Amps |
81vdc Latch mode. The power supply shall return to normal operation only after the power is turned on again |
91% |
| ELP120-1286 | 86 Volts (DC) | 1.4 Amps |
103vdc Latch mode. The power supply shall return to normal operation only after the power is turned on again |
91% |
| ELP120-12114 | 114 Volts (DC) | 1.05 Amps |
136vdc Latch mode. The power supply shall return to normal operation only after the power is turned on again |
92% |
| ELP120-12171 | 171 Volts (DC) | 0.7 Amps |
205vdc Latch mode. The power supply shall return to normal operation only after the power is turned on again |
92% |
| ELP120-12266 | 266 Volts (DC) | 0.45 Amps |
319vdc Latch mode. The power supply shall return to normal operation only after the power is turned on again |
92% |
| ELP120-12343 | 343 Volts (DC) | 0.35 Amps | 411vdc Latch mode. The power supply shall return to normal operation only after the power is turned on again |
ELP120 series
|
Input Specifications
General Specifications
Environmental Specifications
|
Output Specifications
Physical Specifications
Notes All specifications are typical at nominal input, full load, and 25°C unless otherwise noted Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. |