Order by phone: 1-800-823-8082 / +1-508-964-6300 M-F 8:30am to 5:30pm EST

ELP120 120 Watt Constant Current Power Supplies

120W LED Driver

Ultra High Efficiency (Up to 92%)

Active Power Factor Correction (typ 0.99)

Constant Output Current

Waterproof (IP67)

All-Round Protection: OVP, SCP, OTP

Complies with Worldwide Safety & EMC Regulations

Lightning Protection

Model Number

Output Voltage

Output Amps

Over Voltage Protection

Efficiency

ELP120-1224

24 Volts (DC)

4.9 Amps

28vdc Latch mode. The power supply shall return to normal operation only after the power is turned on again

90.5%

ELP120-1228 28 Volts (DC)

4.2 Amps

33vdc Latch mode. The power supply shall return to normal operation only after the power is turned on again

90.5%

ELP120-1234 34 Volts (DC)

3.5 Amps

40vdc Latch mode. The power supply shall return to normal operation only after the power is turned on again

90.5%

ELP120-1238 38 Volts (DC)

3.15 Amps

45vdc Latch mode. The power supply shall return to normal operation only after the power is turned on again

90.5%

ELP120-1243 43 Volts (DC)

2.8 Amps

51vdc Latch mode. The power supply shall return to normal operation only after the power is turned on again

91%

ELP120-1249 49 Volts (DC)

2.45 Amps

58vdc Latch mode. The power supply shall return to normal operation only after the power is turned on again

91%

ELP120-1257 57 Volts (DC)

2.1 Amps

68vdc Latch mode. The power supply shall return to normal operation only after the power is turned on again

91%

ELP120-1268 68 Volts (DC)

1.75 Amps

81vdc Latch mode. The power supply shall return to normal operation only after the power is turned on again

91%

ELP120-1286 86 Volts (DC)

1.4 Amps

103vdc Latch mode. The power supply shall return to normal operation only after the power is turned on again

91%

ELP120-12114 114 Volts (DC)

1.05 Amps

136vdc Latch mode. The power supply shall return to normal operation only after the power is turned on again

92%

ELP120-12171 171 Volts (DC)

0.7 Amps

205vdc Latch mode. The power supply shall return to normal operation only after the power is turned on again

92%

ELP120-12266 266 Volts (DC)

0.45 Amps

319vdc Latch mode. The power supply shall return to normal operation only after the power is turned on again

92%

ELP120-12343 343 Volts (DC) 0.35 Amps 411vdc Latch mode. The power supply shall return to normal operation only after the power is turned on again  

ELP120 series

Input Specifications

Input Voltage Range

90-305VAC

Input Current

1.5 Amps max @ 90VAC

Frequency Range

47-63 Hz

General Specifications

Efficiency

up to 93%

Safety Approvals

USA & Canada: UL8750 Complianace to UL1310 Class 2, UL1012, UL935, CAN/CSA-C22.2 No 107.1, CSA-C22.2 No 250.0;

CE Europe: EN61347-1, EN61347-2-13

EMI

EN55015, Conducted & Radiated emission test with 6dB margin @ 220Vin

EMS

Compliance to EN61000-4-2,3,4,5,6,8,11; EN61000-3-2,3 EN61547

Environmental Specifications

Operating Temperature

-35°C to +70°C 10~100% RH (See Derate Curve)

Storage Temperature

-40°C to +85°C, 5~100% RH

MTBF

460,000 Hrs min, MIL-HDBK-217F ( 25°C)

Life Time 80,000 Hrs @ 220Vin. 80% Load, 45°C

IP Rating

IP67

Output Specifications

Output Voltage

See Selection Chart Above

Output Amps

See Selection Chart Above

Load Regulation

5.0%

Line Regulation

1.0%

Ripple and Noise

3% pk-pk / 20MHz 0.1uF ceramic capacitor 10uF eletrolytic capacitor

Turn-on Delay Time 0.6-1.0S

Over Voltage Protection

See Selection Chart Above

Over Temperature Protection

110°C max temperature of components inside the case

Short Circuit Protection

No damage shall occur when any output operating in a short circuit condition. The power supply shall be self-recovery when the fault condition is removed

Physical Specifications

Size (mm)

194 x 67.5 x 37 mm

Size (Inches)

7.64” x 2.66” x 1.46”

Weight (g)

1000g

Weight (oz)

35.27 oz

Notes

All specifications are typical at nominal input, full load, and 25°C unless otherwise noted

Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.