Order by phone: 1-800-823-8082 / +1-508-964-6300 M-F 8:30am to 5:30pm EST

ELN60 60w Constant Current LED/Lighting Power Supplies

60W Single Output Class 2 Switching Power Supply

Universal AC input / Full range

Fully isolated plastic case with IP64 level

Built-in constant current limiting circuit with adjustable OCP level

Protections: Overload / Over voltage

UL1310 Class 2 power unit

Cooling by free air convection

Model Number

Output Voltage

Output Amps

DC Voltage Adjust (typ.)

Ripple and Noise

Over Voltage Protection

Current Adjustment Range

LED Voltage Operation

Efficiency

ELN60-9

ELN60-9D

ELN60-9P

9 Volts(DC)

5 Amps

8.7~10.5 Volts(DC) Can be adjusted by internal potential meter SVR1 (Note 4)

120 mV pk-pk (Note 1)

11~13.5 Volts(DC) Shut down o/p voltage, re-power

-25%~3%. Can be adjusted by internal potential meter SVR2

3~9Volts (Note 5)

82%

ELN60-12

ELN60-12D

ELN60-12P

12 Volts(DC)

5 Amps

10.8~13.2 Volts(DC) Can be adjusted by internal potential meter SVR1 (Note 4)

120 mV pk-pk (Note 1)

13.8~16 Volts(DC) Shut down o/p voltage, re-power

-25%~3%. Can be adjusted by internal potential meter SVR3

3~12Volts (Note 5)

85%

ELN60-15

ELN60-15D

ELN60-15P

15 Volts(DC)

4 Amps

13.5~16.5 Volts(DC) Can be adjusted by internal potential meter SVR1 (Note 4)

150 mV pk-pk (Note 1)

17.5~21 Volts(DC) Shut down o/p voltage, re-power

-25%~3%. Can be adjusted by internal potential meter SVR4

3~15Volts (Note 5)

86%

ELN60-24

ELN60-24D

ELN60-24P

24 Volts(DC)

2.5 Amps

21.6~26.4 Volts(DC) Can be adjusted by internal potential meter SVR1 (Note 4)

150 mV pk-pk (Note 1)

28~32 Volts(DC) Shut down o/p voltage, re-power

-25%~3%. Can be adjusted by internal potential meter SVR5

3~24Volts (Note 5)

87%

ELN60-27

ELN60-27D

ELN60-27P

27 Volts(DC)

2.3 Amps

24.3~29.7 Volts(DC) Can be adjusted by internal potential meter SVR1 (Note 4)

200 mV pk-pk (Note 1)

31~35 Volts(DC) Shut down o/p voltage, re-power

-25%~3%. Can be adjusted by internal potential meter SVR6

3~27Volts (Note 5)

87%

ELN60-48

ELN60-48D

ELN60-48P

48 Volts(DC)

1.3 Amps

43.2~52.8 Volts(DC) Can be adjusted by internal potential meter SVR1 (Note 4)

250 mV pk-pk (Note 1)

54~60 Volts(DC) Shut down o/p voltage, re-power

-25%~3%. Can be adjusted by internal potential meter SVR7

3~48Volts (Note 5)

88%

*This product is available with a Dimmer Control feature. There are 2 types of dimmer controls:

1. 1.1~10VDC Control ("D" Type)

2. PWM control ("P" Type)

ELN60 series

Input Specifications

Input Voltage Range

90-264VAC

Input Current

1.2 Amps max @ 115VAC; 0.7 Amps max @ 230VAC

Frequency Range

47-63 Hz

Inrush Current

60Amps/230VAC

Leakage Current

0.25mAmps/240VAC

DC Voltage Adjust (typ.)

8.7~10.5 Volts(DC) Can be adjusted by internal potential meter SVR1 (Note 4)

General Specifications

Isolation

3 KVAC Input/Output

Efficiency

82%

Safety Approvals

UL1310 Class 2, CAN/CSA C22.2 No. 223-M91 (except for 48Volts) design refer to TUV EN60950-1, EN61347-2-13

Insulation Resistance

I/P-O/P >100M? / 500VDC / 25°C/70%RH

EMI

Compliance to EN55022(CISPR22) Class B

EMS

Compliance to EN61000-4-2,3,4,6,8,11; ENV50204; EN55024 light industry level, criteria A

Harmonic Current

Compliance to EN61000-3-2,-3

Environmental Specifications

Operating Temperature

-20°C to +60°C (See Derate Curve)

Storage Temperature

-40°C to +85°C, 10~95% RH

Relative Humidity

20~90% RH non cond

MTBF

603KHrs min, MIL-HDBK-217F (25°C)

Vibration

10~500Hz, 2G 10min./1cycle, preiod for 60min. each along X,Y, Z axes

Cooling

free air convection

IP Rating

IP64

Temperature Coefficient

±0.03%/°C (0~50°C)

Output Specifications

Output Voltage

9 Volts(DC)

Output Amps

5 Amps

Dimming Range

1~10Volts(DC) or PWM signal:100Hz~3KHz (optional)

Load Regulation

±2.0%

Line Regulation

±1.0%

Ripple and Noise

120 mV pk-pk (Note 1)

Over Voltage Protection

11~13.5 Volts(DC) Shut down o/p voltage, re-power

Current Adjustment Range

-25%~3%. Can be adjusted by internal potential meter SVR2

Over Current Protection

9~12Volts(DC) 95~110%; 15~48Volts(DC) 130% max Constant current limiting, auto recov after fault condition is removed (Note 3)

Hold Up Time

50ms/230VAC ; 16ms/115VAC

LED Voltage Operation

3~9Volts (Note 5)

Rise Time

500ms, 30ms/230VAC 1500ms, 30ms/115VAC

Voltage Tolerance

±5.0% (Note 2)

Physical Specifications

Size (mm)

181 x61.5 x 35 mm

Size (Inches)

7.13” x 2.42” x 1.38”

Weight (g)

400g

Weight (oz)

14.11 oz

Notes

1. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

2. Tolerance : includes set up tolerance, line regulation and load regulation.

3. Derating may be needed under low input voltage. Please check the derating curve for more details.

4. Output voltage can be adjusted through the SVR1 on the PCB ; limit of output constant current level can be adjusted through the SVR2 on the PCB.

5. Constant current operation region is within the specified output voltage

range above. This is the suitable operation region for LED related applications.

All specifications are typical at nominal input, full load, and 25°C unless otherwise noted

Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.