Order by phone: 1-800-823-8082 / +1-508-964-6300 M-F 8:30am to 5:30pm EST

ELN30 30w Constant Current LED/Lighting Power Supplies

30W Single Output Class 2 Switching Power Supply

Universal AC input / Full range

Fully isolated plastic case with IP64 level

Built-in constant current limiting circuit with adjustable OCP level

Protections: Short circuit / Overload / Over voltage

UL1310 Class 2 power unit

Cooling by free air convection

Model Number

DC Voltage Adjust (typ.)

Output Voltage

Output Amps

Ripple and Noise

Over Voltage Protection

Current Adjustment Range

LED Voltage Operation

Efficiency

ELN30-5

ELN30-5D

ELN30-5P

4.5~5.5 Volts(DC) Can be adjusted by internal potential meter SVR1

5 Volts(DC)

5.00 Amps

80 mV pk-pk (Note 1)

5.75~6.75 Volts(DC) Shut down o/p voltage, re-power

-25%~3%. Can be adjusted by internal potential meter SVR2

3~5Volts

75%

ELN30-9

ELN30-9D

ELN30-9P

8.7~10.5 Volts(DC) Can be adjusted by internal potential meter SVR1

9 Volts(DC)

3.40 Amps

100 mV pk-pk (Note 1)

11~13.5 Volts(DC) Shut down o/p voltage, re-power

-25%~3%. Can be adjusted by internal potential meter SVR3

3~9Volts

80%

ELN30-12

ELN30-12D

ELN30-12P

10.8~13.2 Volts(DC) Can be adjusted by internal potential meter SVR1

12 Volts(DC)

2.50 Amps

120 mV pk-pk (Note 1)

13.8~16 Volts(DC) Shut down o/p voltage, re-power

-25%~3%. Can be adjusted by internal potential meter SVR4

3~12Volts

82%

ELN30-15

ELN30-15D

ELN30-15P

13.5~16.5 Volts(DC) Can be adjusted by internal potential meter SVR1

15 Volts(DC)

2.00 Amps

120 mV pk-pk (Note 1)

17.5~21 Volts(DC) Shut down o/p voltage, re-power

-25%~3%. Can be adjusted by internal potential meter SVR5

3~15Volts

82%

ELN30-24

ELN30-24D

ELN30-24P

21.6~26.4 Volts(DC) Can be adjusted by internal potential meter SVR1

24 Volts(DC)

1.25 Amps

150 mV pk-pk (Note 1)

28~32 Volts(DC) Shut down o/p voltage, re-power

-25%~3%. Can be adjusted by internal potential meter SVR6

3~24Volts

85%

ELN30-27

ELN30-27D

ELN30-27P

24.3~29.7 Volts(DC) Can be adjusted by internal potential meter SVR1

27 Volts(DC)

1.12 Amps

150 mV pk-pk (Note 1)

31~36.4 Volts(DC) Shut down o/p voltage, re-power

-25%~3%. Can be adjusted by internal potential meter SVR7

3~27Volts

85%

ELN30-48

ELN30-48D

ELN30-48P

43.2~52.8 Volts(DC) Can be adjusted by internal potential meter SVR1

48 Volts(DC)

0.63 Amps

250 mV pk-pk (Note 1)

54~60 Volts(DC) Shut down o/p voltage, re-power

-25%~3%. Can be adjusted by internal potential meter SVR8

3~48Volts

87%

*This product is available with a Dimmer Control feature. There are 2 types of dimmer controls:

1. 1.1~10VDC Control ("D" Type)

2. PWM control ("P" Type)

ELN30 series

Input Specifications

Input Voltage Range

90-264VAC

Input Current

0.75 Amps @ 115VAC; 0.48 Amps @ 230VAC

Frequency Range

47-63 Hz

Inrush Current

60Amps/230VAC (Cold start)

Leakage Current

0.25mAmps/240VAC

DC Voltage Adjust (typ.)

4.5~5.5 Volts(DC) Can be adjusted by internal potential meter SVR1

General Specifications

Isolation

3 KVAC Input/Output

Efficiency

75%

Safety Approvals

UL1310 Class 2, CAN/CSA C22.2 No. 223-M91 (except for 48Volts) design refer to TUV EN60950-1, EN61347-2-13

Insulation Resistance

I/P-O/P >100M? / 500VDC / 25°C/70%RH

EMI

Compliance to EN55022(CISPR22) Class B

EMS

Compliance to EN61000-4-2,3,4,6,8,11; ENV50204; EN55024 light industry level, criteria A

Harmonic Current

Compliance to EN61000-3-2,-3

Environmental Specifications

Operating Temperature

-20°C to +60°C (See Derate Curve)

Storage Temperature

-40°C to +85°C, 10~95% RH

Relative Humidity

20~90% RH non cond

MTBF

628.3KHrs min, MIL-HDBK-217F (25°C)

Vibration

10~500Hz, 2G 10min./1cycle, preiod for 60min. each along X,Y, Z axes

Cooling

free air convection

IP Rating

IP64

Temperature Coefficient

±0.03%/°C (0~50°C)

Output Specifications

Output Voltage

5 Volts(DC)

Output Amps

5.00 Amps

Dimming Range

1~10Volts(DC) or PWM (optional)

Load Regulation

±2.0%

Line Regulation

±1.0%

Ripple and Noise

80 mV pk-pk (Note 1)

Over Voltage Protection

5.75~6.75 Volts(DC) Shut down o/p voltage, re-power

Current Adjustment Range

-25%~3%. Can be adjusted by internal potential meter SVR2

Over Current Protection

95~110% Constant current limiting, auto recov after fault condition is removed (Note 3)

Hold Up Time

50ms/230VAC ; 16ms/115VAC

LED Voltage Operation

3~5Volts

Rise Time

500ms, 80ms/230VAC 1000ms, 80ms/115VAC

Voltage Tolerance

±5.0% (Note 2)

Physical Specifications

Size (mm)

145 x 47 x 30 mm

Size (Inches)

5.71” x 1.85” x 1.18”

Weight (g)

260g

Weight (oz)

9.17 oz

Notes

1. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

2. Tolerance : includes set up tolerance, line regulation and load regulation.

3. Derating may be needed under low input voltage. Please check the derating curve for more details.

4. Constant current operation region is within the specified output voltage

range above. This is the suitable operation region for LED related applications.

All specifications are typical

\at nominal input, full load, and 25°C unless otherwise noted

Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.