30W Single Output Class 2 Switching Power Supply
ELN30 30w Constant Current LED/Lighting Power Supplies
|
Universal AC input / Full range |
|
|
Fully isolated plastic case with IP64 level |
|
|
Built-in constant current limiting circuit with adjustable OCP level |
|
|
Protections: Short circuit / Overload / Over voltage |
|
|
UL1310 Class 2 power unit |
|
|
Cooling by free air convection |
|
Model Number |
DC Voltage Adjust (typ.) |
Output Voltage |
Output Amps |
Ripple and Noise |
Over Voltage Protection |
Current Adjustment Range |
LED Voltage Operation |
Efficiency |
|
4.5~5.5 Volts(DC) Can be adjusted by internal potential meter SVR1 |
5 Volts(DC) |
5.00 Amps |
80 mV pk-pk (Note 1) |
5.75~6.75 Volts(DC) Shut down o/p voltage, re-power |
-25%~3%. Can be adjusted by internal potential meter SVR2 |
3~5Volts |
75% |
|
|
8.7~10.5 Volts(DC) Can be adjusted by internal potential meter SVR1 |
9 Volts(DC) |
3.40 Amps |
100 mV pk-pk (Note 1) |
11~13.5 Volts(DC) Shut down o/p voltage, re-power |
-25%~3%. Can be adjusted by internal potential meter SVR3 |
3~9Volts |
80% |
|
|
10.8~13.2 Volts(DC) Can be adjusted by internal potential meter SVR1 |
12 Volts(DC) |
2.50 Amps |
120 mV pk-pk (Note 1) |
13.8~16 Volts(DC) Shut down o/p voltage, re-power |
-25%~3%. Can be adjusted by internal potential meter SVR4 |
3~12Volts |
82% |
|
|
13.5~16.5 Volts(DC) Can be adjusted by internal potential meter SVR1 |
15 Volts(DC) |
2.00 Amps |
120 mV pk-pk (Note 1) |
17.5~21 Volts(DC) Shut down o/p voltage, re-power |
-25%~3%. Can be adjusted by internal potential meter SVR5 |
3~15Volts |
82% |
|
|
21.6~26.4 Volts(DC) Can be adjusted by internal potential meter SVR1 |
24 Volts(DC) |
1.25 Amps |
150 mV pk-pk (Note 1) |
28~32 Volts(DC) Shut down o/p voltage, re-power |
-25%~3%. Can be adjusted by internal potential meter SVR6 |
3~24Volts |
85% |
|
|
24.3~29.7 Volts(DC) Can be adjusted by internal potential meter SVR1 |
27 Volts(DC) |
1.12 Amps |
150 mV pk-pk (Note 1) |
31~36.4 Volts(DC) Shut down o/p voltage, re-power |
-25%~3%. Can be adjusted by internal potential meter SVR7 |
3~27Volts |
85% |
|
|
43.2~52.8 Volts(DC) Can be adjusted by internal potential meter SVR1 |
48 Volts(DC) |
0.63 Amps |
250 mV pk-pk (Note 1) |
54~60 Volts(DC) Shut down o/p voltage, re-power |
-25%~3%. Can be adjusted by internal potential meter SVR8 |
3~48Volts |
87% |
|
*This product is available with a Dimmer Control feature. There are 2 types of dimmer controls:
|
||||||||
ELN30 series
|
Input Specifications
General Specifications
Environmental Specifications
|
Output Specifications
Physical Specifications
Notes 1. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 2. Tolerance : includes set up tolerance, line regulation and load regulation. 3. Derating may be needed under low input voltage. Please check the derating curve for more details. 4. Constant current operation region is within the specified output voltage range above. This is the suitable operation region for LED related applications. All specifications are typical \at nominal input, full load, and 25°C unless otherwise noted Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. |