Order by phone: 1-800-823-8082 / +1-508-964-6300 M-F 8:30am to 5:30pm EST

EFM30 30w Power Supplies

Universal 90-264VAC Input

High Efficiency

Improved EMI Performance

3000V Isolation

Single, Dual and Triple Outputs

UL60950-1, EN60950-1

Model Number

Output Voltage

Output Amps

Load Regulation

Line Regulation

Cross Regulation

Ripple and Noise

Size (mm)

Size (Inches)

Efficiency

Switching Frequency

EFM-0300

3.3 Volts(DC)

7.5 Amps *2

3% *3

±1%, max. (LL-HL)

100mV typ. *1, 4

59.94 x 86.61 x 23.62 mm

2.36” x 3.41” x 0.93”

73%

100mV typ. *1, 4

EFM-0301

5 Volts(DC)

6 Amps *2

2% *3

±1%, max. (LL-HL)

70mV typ. *1, 4

59.94 x 86.61 x 23.62 mm

2.36” x 3.41” x 0.93”

78%

70mV typ.*1, 4

EFM-0302

12 Volts(DC)

2.5 Amps *2

1% *3

±1%, max. (LL-HL)

70mV typ. *1, 4

59.94 x 86.61 x 23.62 mm

2.36” x 3.41” x 0.93”

83%

70mV typ.*1, 4

EFM-0303

15 Volts(DC)

2 Amps *2

1% *3

±1%, max. (LL-HL)

70mV typ. *1, 4

59.94 x 86.61 x 23.62 mm

2.36” x 3.41” x 0.93”

84%

70mV typ.*1, 4

EFM-0305

24 Volts(DC)

1.25 Amps *2

1% *3

±1%, max. (LL-HL)

50mV typ. *1, 4

59.94 x 86.61 x 23.62 mm

2.36” x 3.41” x 0.93”

84%

50mV typ. *1, 4

EFM-0312

48 Volts(DC)

0.63 Amps *2

1% *3

±1%, max. (LL-HL)

50mV typ. *1, 4

59.94 x 86.61 x 23.62 mm

2.36” x 3.41” x 0.93”

85%

50mV typ. *1, 4

EFM-0306

±12 Volts(DC)

±1.25 Amps *2

±3% *3

±1%, max. (LL-HL)

±2%. max. (0308: ±2 / ±6%)

±50mV typ. *1, 4

59.94 x 100.07 x 23.62 mm

2.36” x 3.94” x 0.93”

80%

±50mV typ. *1, 4

EFM-0307

±15 Volts(DC)

±1 Amps *2

±3% *3

±1%, max. (LL-HL)

±2%. max. (0308: ±2 / ±6%)

±50mV typ. *1, 4

59.94 x 100.07 x 23.62 mm

2.36” x 3.94” x 0.93”

80%

±50mV typ. *1, 4

EFM-0308

5/12 Volts(DC)

3/1.25 Amps *2

±2%/ ±4% *3

±1%, max. (LL-HL)

±2%. max. (0308: ±2 / ±6%)

±50mV typ. *1, 4

59.94 x 100.07 x 23.62 mm

2.36” x 3.94” x 0.93”

74%

±50mV typ. *1, 4

EFM-0309

5/±12 Volts(DC)

3/±0.63 Amps *2

0.6% / ±0.5% *3

0.6 / ±0.2%, max. (LL-HL)

±3% max.

100mV / ±75mV typ. *1, 4

59.94 x 100.07 x 23.62 mm

2.36” x 3.94” x 0.93”

74%

100mV / ±75mV typ. *1, 4

EFM-0311

5/±15 Volts(DC)

3/±0.5 Amps *2

0.6% / ±0.5% *3

0.6 / ±0.2%, max. (LL-HL)

±3% max.

100mV / ±75mV typ. *1, 4

59.94 x 100.07 x 23.62 mm

2.36” x 3.94” x 0.93”

74%

100mV / ±75mV typ. *1, 4

EFM30 series

Input Specifications

Input Voltage Range

90-264 VAC

Frequency Range

47-63 Hz

Inrush Current

30A@115V, 60A@230V Input *

Environmental Specifications

Operating Temperature

-10 to +70°C with Derate (free air)

EMC

EN55022, class II

Storage Temperature

-25 to +71°C *

Relative Humidity

0 to + 95%, non-cond *

General Specifications

Isolation

3000VAC (1 minute max)

Efficiency

73%

Switching Frequency

100mV typ. *1, 4

Safety Approvals

UL60950-1, EN60950-1

Output Specifications

Output Voltage

3.3 Volts(DC)

Output Amps

7.5 Amps *2

Load Regulation

3% *3

Line Regulation

±1%, max. (LL-HL)

Preset Accuracy

1% (0308: ±2 / ±5%) 1 / ±5% (FL,120VAC)

Temperature Coefficient

±0.03%/°C (0-50°C, typ)

Ripple and Noise

100mV typ. *1, 4

Over Voltage Protection

Latching Auto Recovery *

Over Current Protection

>110% of FS, Power Limit, Self- Recovering

Short Circuit Protection

Latching Auto Recovery *

Hold Up Time

20 mS, typ

DC Voltage Adjust (typ.)

±10% of FS (Primary)

Physical Specifications

Size (mm)

59.94 x 86.61 x 23.62 mm

Size (Inches)

2.36” x 3.41” x 0.93”

Construction

Open Frame

Weight (g)

122g

Weight (oz)

4.3oz

Notes

1. All measurements should be made directly at the terminals of the power supply

2. Minimum Load is NOT required for proper operation. However, auxiliary

outputs should be reduced as a function of primary output minimum load or load reugulation will be higher.

3. Load Regulation measured from 20% to full load. All other outputs at nominal load.

4. Output noise measured directky at pins at nomimnal load with 0.1uF and 10uF capacitors, pk-pk @ 20MHz bandwidth.

* These are stress ratings. Exposure of the devices to any of these conditions may adversely affect long term reliability. Proper operation under conditions other than the standard operating conditions is neither warranteed nor implied.

All specifications are typical at nominal input, full load, and 25°C unless otherwise noted

Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.