Universal 90-264VAC Input |
|
|
High Efficiency |
|
|
Improved EMI Performance |
|
|
3000V Isolation |
|
|
Single, Dual and Triple Outputs |
|
|
UL60950-1, EN60950-1 |
EFM30 30 Watt Power Supplies
|
Model Number |
Output Voltage |
Output Amps |
Load Regulation |
Line Regulation |
Cross Regulation |
Ripple and Noise |
Size (mm) |
Size (Inches) |
Efficiency |
Switching Frequency |
| EFM-0300 | 3.3vdc | 7.5 Amps *2 |
3% *3 |
±1%, max. (LL-HL) |
100mV typ. *1, 4 |
59.94 x 86.61 x 23.62 mm |
2.36” x 3.41” x 0.93” |
73% |
100mV typ. *1, 4 |
|
| EFM-0301 | 5vdc | 6 Amps *2 |
2% *3 |
±1%, max. (LL-HL) |
70mV typ. *1, 4 |
59.94 x 86.61 x 23.62 mm |
2.36” x 3.41” x 0.93” |
78% |
70mV typ.*1, 4 |
|
| EFM-0302 | 12vdc | 2.5 Amps *2 |
1% *3 |
±1%, max. (LL-HL) |
70mV typ. *1, 4 |
59.94 x 86.61 x 23.62 mm |
2.36” x 3.41” x 0.93” |
83% |
70mV typ.*1, 4 |
|
| EFM-0303 | 15vdc | 2 Amps *2 |
1% *3 |
±1%, max. (LL-HL) |
70mV typ. *1, 4 |
59.94 x 86.61 x 23.62 mm |
2.36” x 3.41” x 0.93” |
84% |
70mV typ.*1, 4 |
|
| EFM-0305 | 24vdc | 1.25 Amps *2 |
1% *3 |
±1%, max. (LL-HL) |
50mV typ. *1, 4 |
59.94 x 86.61 x 23.62 mm |
2.36” x 3.41” x 0.93” |
84% |
50mV typ. *1, 4 |
|
| EFM-0312 | 48vdc | 0.63 Amps *2 |
1% *3 |
±1%, max. (LL-HL) |
50mV typ. *1, 4 |
59.94 x 86.61 x 23.62 mm |
2.36” x 3.41” x 0.93” |
85% |
50mV typ. *1, 4 |
|
| EFM-0306 | ±12vdc | ±1.25 Amps *2 |
±3% *3 |
±1%, max. (LL-HL) |
±2%. max. (0308: ±2 / ±6%) |
±50mV typ. *1, 4 |
59.94 x 100.07 x 23.62 mm |
2.36” x 3.94” x 0.93” |
80% |
±50mV typ. *1, 4 |
| EFM-0307 | ±15vdc | ±1 Amps *2 |
±3% *3 |
±1%, max. (LL-HL) |
±2%. max. (0308: ±2 / ±6%) |
±50mV typ. *1, 4 |
59.94 x 100.07 x 23.62 mm |
2.36” x 3.94” x 0.93” |
80% |
±50mV typ. *1, 4 |
| EFM-0308 | 5/12vdc | 3/1.25 Amps *2 |
±2%/ ±4% *3 |
±1%, max. (LL-HL) |
±2%. max. (0308: ±2 / ±6%) |
±50mV typ. *1, 4 |
59.94 x 100.07 x 23.62 mm |
2.36” x 3.94” x 0.93” |
74% |
±50mV typ. *1, 4 |
| EFM-0309 | 5/±12vdc | 3/±0.63 Amps *2 |
0.6% / ±0.5% *3 |
0.6 / ±0.2%, max. (LL-HL) |
±3% max. |
100mV / ±75mV typ. *1, 4 |
59.94 x 100.07 x 23.62 mm |
2.36” x 3.94” x 0.93” |
74% |
100mV / ±75mV typ. *1, 4 |
| EFM-0311 | 5/±15vdc | 3/±0.5 Amps *2 |
0.6% / ±0.5% *3 |
0.6 / ±0.2%, max. (LL-HL) |
±3% max. |
100mV / ±75mV typ. *1, 4 |
59.94 x 100.07 x 23.62 mm |
2.36” x 3.94” x 0.93” |
74% |
100mV / ±75mV typ. *1, 4 |
EFM30 series
|
Input Specifications
Environmental Specifications
General Specifications
|
Output Specifications
Physical Specifications
Notes 1. All measurements should be made directly at the terminals of the power supply 2. Minimum Load is NOT required for proper operation. However, auxiliary outputs should be reduced as a function of primary output minimum load or load reugulation will be higher. 3. Load Regulation measured from 20% to full load. All other outputs at nominal load. 4. Output noise measured directky at pins at nomimnal load with 0.1uF and 10uF capacitors, pk-pk @ 20MHz bandwidth. * These are stress ratings. Exposure of the devices to any of these conditions may adversely affect long term reliability. Proper operation under conditions other than the standard operating conditions is neither warranteed nor implied. All specifications are typical at nominal input, full load, and 25°C unless otherwise noted Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. |