Order by phone: 1-800-823-8082 / +1-508-964-6300 M-F 8:30am to 5:30pm EST

EFM10 10 Watt Open Frame Power Supplies

EFM10 10 Watt  Open Frame Power Supplies

Universal 90-264VAC Input

High Efficiency

Improved EMI Performance

3000V Isolation

Single, Dual & Triple Outputs

UL60950-1, EN60950-1

Model Number

Output Voltage

Output Amps

Load Regulation

Line Regulation

Cross Regulation

Preset Accuracy

Ripple and Noise

Efficiency

EFM-0100

3.3vdc

2.5 Amps

± 3% (20% FL) (note 6)

± 0.1~1% (note 7)

1% (except EFM-0108: 2 / 5%) (note 8)

100mVpk-pk (except EFM-0108: 50/50mVpk-pk) (note 1, 9)

75% typ

EFM-0101

5vdc

2 Amps

± 3% (20% FL) (note 6)

± 0.1~1% (note 7)

1% (except EFM-0108: 2 / 5%) (note 8)

100mVpk-pk (except EFM-0108: 50/50mVpk-pk) (note 1, 9)

75% typ

EFM-0122

9vdc

1.1 Amps

± 3% (20% FL) (note 6)

± 0.1~1% (note 7)

1% (except EFM-0108: 2 / 5%) (note 8)

100mVpk-pk (except EFM-0108: 50/50mVpk-pk) (note 1, 9)

75% typ

EFM-0102

12vdc

0.85 Amps

± 3% (20% FL) (note 6)

± 0.1~1% (note 7)

1% (except EFM-0108: 2 / 5%) (note 8)

100mVpk-pk (except EFM-0108: 50/50mVpk-pk) (note 1, 9)

75% typ

EFM-0103

15vdc

0.67 Amps

± 3% (20% FL) (note 6)

± 0.1~1% (note 7)

1% (except EFM-0108: 2 / 5%) (note 8)

100mVpk-pk (except EFM-0108: 50/50mVpk-pk) (note 1, 9)

75% typ

EFM-0105

24vdc

0.42 Amps

± 3% (20% FL) (note 6)

± 0.1~1% (note 7)

1% (except EFM-0108: 2 / 5%) (note 8)

100mVpk-pk (except EFM-0108: 50/50mVpk-pk) (note 1, 9)

75% typ

EFM-0106

±12vdc

±0.42 Amps

± 3% (EFM-0108: 0.5/3%) (20% FL) (note 6)

± 0.3~1% (except EFM-0108: 0.5/ 0.5%) (note 7)

2% (EFM-0108: 0.5/3%) (note 10)

1% (except EFM-0108: 2 / 5%) (note 8)

100mVpk-pk (except EFM-0108: 50/50mVpk-pk) (note 1, 9)

75% typ

EFM-0107

±15vdc

±0.34 Amps

± 3% (EFM-0108: 0.5/3%) (20% FL) (note 6)

± 0.3~1% (except EFM-0108: 0.5/ 0.5%) (note 7)

2% (EFM-0108: 0.5/3%) (note 10)

1% (except EFM-0108: 2 / 5%) (note 8)

100mVpk-pk (except EFM-0108: 50/50mVpk-pk) (note 1, 9)

75% typ

EFM-0108

5 / 12Volts(DC)

1.3 / 0.6 Amps

± 3% (EFM-0108: 0.5/3%) (20% FL) (note 6)

± 0.3~1% (except EFM-0108: 0.5/ 0.5%) (note 7)

2% (EFM-0108: 0.5/3%) (note 10)

1% (except EFM-0108: 2 / 5%) (note 8)

100mVpk-pk (except EFM-0108: 50/50mVpk-pk) (note 1, 9)

75% typ

EFM-0109

5/ ±12vdc

1.8 / ±0.13 Amps

0.2 / ±0.3% (20% FL) (note 6)

0.3 / ±0.1% (note 7)

NA/ ±0.1% (note 10)

1 / ±5% (note 8)

50 / ±75mVpk-pk (note 1, 9)

70%

EFM-0111

5/ ±15vdc

1.8/ ±0.13 Amps

0.2 / ±0.3% (20% FL) (note 6)

0.3 / ±0.1% (note 7)

NA/ ±0.1% (note 10)

1 / ±5% (note 8)

50 / ±75mVpk-pk (note 1, 9)

70%

EFM10 series

Input Specifications

Input Voltage Range

90-264 VAC

Frequency Range

47-63 Hz

Inrush Current

20Amps @115 Volts(DC;) 40Amps @230vdc

Environmental Specifications

Operating Temperature

-0 to +40°C (See Derate) (note 4)

EMC

EN55022

Storage Temperature

-25 to +71°C *

MTBF

575,000 Hrs, Mil Std 217, 25°C

General Specifications

Isolation

3000VAC (note 3)

Isolation Input-Ground

2500VAC (Note 3)

Isolation Output-Ground

1000VAC (note 3)

Efficiency

75% typ

Switching Frequency

100Khz, (fixed, typical)

Safety Approvals

UL60950-1, EN60950-1

Output Specifications

Output Voltage

3.3vdc

Output Amps

2.5 Amps

Load Regulation

± 3% (20% FL) (note 6)

Line Regulation

± 0.1~1% (note 7)

Preset Accuracy

1% (except EFM-0108: 2 / 5%) (note 8)

Temperature Coefficient

±0.03%/°C

Ripple and Noise

100mVpk-pk (except EFM-0108: 50/50mVpk-pk) (note 1, 9)

Over Voltage Protection

Clamp

Over Temperature Protection

Latching, recov after cooling and power restored

Short Circuit Protection

Continuous, self-recovering (note 2)

Hold Up Time

30 mS, typ

DC Voltage Adjust (typ.)

± 6% of FS (Primary)

Physical Specifications

Size (mm)

42.16 x 62.48 x 23.11 mm

Size (Inches)

1.66” x 2.46” x 0.91”

Construction

Open Frame

Weight (g)

44g

Weight (oz)

1.6oz

Notes

All specifications are typical at nominal input, full load, and 25°C unless otherwise noted

Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.