Order by phone: 1-800-823-8082 / +1-508-964-6300 M-F 8:30am to 5:30pm EST

DR1P5 1w Power Supplies

Isolated and Regulated 1.5 WATT Modular DC/DC Converters

Low Ripple and Noise

PI Input Filter

Regulated Outputs

500V Isolation

5 Sided EMI Shielding

Standard 24 Pin DIP & SMD Packages

Model Number

Input Voltage Range

Output Voltage

Output Amps

Load Regulation

Cross Regulation

DR1P5-05S05(SMD)

4.5-5.5 VDC

5 VDC

0.3Amps

±1.5% 20% to FL

DR1P5-12S05(SMD)

10.8-13.2 VDC

5 VDC

0.3Amps

±0.5% 20% to Fl

DR1P5-24S05(SMD)

21.6-26.4 VDC

5 VDC

0.3Amps

±0.5% 20% to Fl

DR1P5-05S12(SMD)

4.5-5.5 VDC

12 VDC

0.125Amps

±0.5% 20% to Fl

DR1P5-12S12(SMD)

10.8-13.2 VDC

12 VDC

0.125Amps

±0.5% 20% to Fl

DR1P5-24S12(SMD)

21.6-26.4 VDC

12 VDC

0.125Amps

±0.5% 20% to Fl

DR1P5-05S15(SMD)

4.5-5.5 VDC

15 VDC

0.1Amps

±0.5% 20% to Fl

DR1P5-12S15(SMD)

10.8-13.2 VDC

15 VDC

0.1Amps

±0.5% 20% to Fl

DR1P5-24S15(SMD)

21.6-26.4 VDC

15 VDC

0.1Amps

±0.5% 20% to Fl

DR1P5-05D05(SMD)

4.5-5.5 VDC

±5 VDC

±0.15Amps

±1.5% 20% to FL

±5% Asymmetrical Load 25/100%

DR1P5-12D05(SMD)

10.8-13.2 VDC

±5 VDC

±0.15Amps

±0.5% 20% to Fl

±5% Asymmetrical Load 25/100%

DR1P5-24D05(SMD)

21.6-26.4 VDC

±5 VDC

±0.15Amps

±0.5% 20% to Fl

±5% Asymmetrical Load 25/100%

DR1P5-05D12(SMD)

4.5-5.5 VDC

±12 VDC

±0.06Amps

±0.5% 20% to Fl

±5% Asymmetrical Load 25/100%

DR1P5-12D12(SMD)

10.8-13.2 VDC

±12 VDC

±0.06Amps

±0.5% 20% to Fl

±5% Asymmetrical Load 25/100%

DR1P5-24D12(SMD)

21.6-26.4 VDC

±12 VDC

±0.06Amps

±0.5% 20% to Fl

±5% Asymmetrical Load 25/100%

DR1P5-05D15(SMD)

4.5-5.5 VDC

±15 VDC

±0.05Amps

±0.5% 20% to Fl

±5% Asymmetrical Load 25/100%

DR1P5-12D15(SMD)

10.8-13.2 VDC

±15 VDC

±0.05Amps

±0.5% 20% to Fl

±5% Asymmetrical Load 25/100%

DR1P5-24D15(SMD)

21.6-26.4 VDC

±15 VDC

±0.05Amps

±0.5% 20% to Fl

±5% Asymmetrical Load 25/100%

DR1P5 series

Input Specifications

Input Voltage Range

4.5-5.5 VDC

Input Filter

PI Type

Environmental Specifications

Case Temperature

100 °C

Storage Temperature

-55 to +105°C

Working Humidity

5 to 95%, RH

EMC

Conducted Emissions EN55022 Class A, Radiated Emissions EN55022 Class A,

ESD EN61000-4-4 Criteria B, Radiated Immunity EN61000-4-3 Criteria A, Fast Transient EN61000-4-4 Criteria B, Surge EN61000-4-5 Criteria B, Conducted Immunity EN61000-4-6 Criteria A

MTBF

5.53 MHrs BELLCORE TR NWT 000332 Case1: 50% Stress,

Output Specifications

Output Voltage

5 VDC

Output Amps

0.3Amps

Load Regulation

±1.5% 20% to FL

Line Regulation

±0.3%

Preset Accuracy

± 4%, max

Temperature Coefficient

±0.02%/°C

Ripple and Noise

50mV Pk-Pk, typ

Short Circuit Protection

Short Term

Notes

All specifications are typical at nominal input, full load, and 25°C unless otherwise noted

Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.