60W Single Output Class 2 Switching Power Supply
CLG60 60w LED/Lighting Power Supplies
|
Universal AC input / Full range |
|
|
Built-in active PFC function |
|
|
Protections: Short Circuit / Over voltage / Overload / Over temperature |
|
|
IP67 design for indoor or outdoor installations |
|
|
UL1310 Class 2 power unit |
|
|
Cooling by free air convection |
|
Model Number |
DC Voltage Adjust (typ.) |
Output Voltage |
Output Amps |
Ripple and Noise |
Over Voltage Protection |
Over Current Protection |
Over Temperature Protection |
Efficiency |
|
11.5~13Volts(DC) |
12 Volts(DC) |
5 Amps |
2 Vpk-pk (Note 1) |
13.8~16 Volts(DC) Shut down o/p voltage, re-power |
95~110% Constant current limiting, auto recov |
90°C±10°C (TSW1) detect on heatsink of power transistor shut down o/p voltage auto recov |
81.5% |
|
|
14.5~16.2Volts(DC) |
15 Volts(DC) |
4 Amps |
2.4 Vpk-pk (Note 1) |
17.5~21 Volts(DC) Shut down o/p voltage, re-power |
110% max Constant current limiting, auto recov |
85°C±10°C detect on heatsink of power transistor shut down o/p voltage auto recov |
84.5% |
|
|
19.5~22Volts(DC) |
20 Volts(DC) |
3 Amps |
1.8 Vpk-pk (Note 1) |
22.8~25 Volts(DC) Shut down o/p voltage, re-power |
110% max Constant current limiting, auto recov |
85°C±10°C detect on heatsink of power transistor shut down o/p voltage auto recov |
86% |
|
|
24~26Volts(DC) |
24 Volts(DC) |
2.5 Amps |
2.7 Vpk-pk (Note 1) |
28~32 Volts(DC) Shut down o/p voltage, re-power |
110% max Constant current limiting, auto recov |
85°C±10°C detect on heatsink of power transistor shut down o/p voltage auto recov |
86% |
|
|
25~30Volts(DC) |
27 Volts(DC) |
2.3 Amps |
2.7 Vpk-pk (Note 1) |
31~35 Volts(DC) Shut down o/p voltage, re-power |
110% max Constant current limiting, auto recov |
85°C±10°C detect on heatsink of power transistor shut down o/p voltage auto recov |
86.5% |
|
|
32.5~39Volts(DC) |
36 Volts(DC) |
1.7 Amps |
3.6 Vpk-pk (Note 1) |
41~46 Volts(DC) Shut down o/p voltage, re-power |
110% max Constant current limiting, auto recov |
85°C±10°C detect on heatsink of power transistor shut down o/p voltage auto recov |
87% |
|
|
43.6~51.8Volts(DC) |
48 Volts(DC) |
1.3 Amps |
4.6Vpk-pk (Note 1) |
54~60 Volts(DC) Shut down o/p voltage, re-power |
110% max Constant current limiting, auto recov |
85°C±10°C detect on heatsink of power transistor shut down o/p voltage auto recov |
87% |
CLG-60 series
|
Input Specifications
General Specifications
Environmental Specifications
|
Output Specifications
Physical Specifications
Notes 1. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. Direct connecting to LEDs is not suggested for models with “RIPPLE & NOISE” > 10% and using additional drivers is highly recommended. 2. Tolerance : includes set up tolerance, line regulation and load regulation. 3. Please refer to OLP characteristics. 4. Derating may be needed under low input voltage. Please check the derating curve for more details. All specifications are typical at nominal input, full load, and 25°C unless otherwise noted Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. |