100W Single Output Class 2 Switching Power Supply
CLG100 100w LED/Lighting Power Supplies
|
Universal AC input / Full range |
|
|
Built-in active PFC function |
|
|
Protections: Short Circuit / Over voltage / Overload / Over temperature |
|
|
IP67 design for indoor or outdoor installations |
|
|
UL1310 Class 2 power unit |
|
|
Cooling by free air convection |
|
Model Number |
Input Current |
Output Voltage |
Output Amps |
Ripple and Noise |
Over Voltage Protection |
Voltage Tolerance |
Efficiency |
|
0.8Amps@115VAC / 0.4 Amps@230VAC |
12 Volts(DC) |
5 Amps |
150 mVpk-pk (Note 1) |
13~16 Volts(DC) Shut down & latch off, o/p volt, re-power |
±3.0% (Note 2) |
83% |
|
|
0.9Amps@115VAC /0.45 Amps@230VAC |
15 Volts(DC) |
5 Amps |
150 mVpk-pk (Note 1) |
16.5~20 Volts(DC) Shut down & latch off, o/p volt, re-power |
±3.0% (Note 2) |
85% |
|
|
1.1Amps@115VAC /0.55 Amps@230VAC |
20 Volts(DC) |
4.8 Amps |
150 mVpk-pk (Note 1) |
22~27 Volts(DC) Shut down & latch off, o/p volt, re-power |
±3.0% (Note 2) |
87% |
|
|
1.1Amps@115VAC /0.55 Amps@230VAC |
24 Volts(DC) |
4 Amps |
150 mVpk-pk (Note 1) |
27~34 Volts(DC) Shut down & latch off, o/p volt, re-power |
±3.0% (Note 2) |
87% |
|
|
1.1Amps@115VAC /0.55 Amps@230VAC |
27 Volts(DC) |
3.55 Amps |
150 mVpk-pk (Note 1) |
29~36 Volts(DC) Shut down & latch off, o/p volt, re-power |
±3.0% (Note 2) |
87% |
|
|
1.1Amps@115VAC /0.55 Amps@230VAC |
36 Volts(DC) |
2.65 Amps |
150 mVpk-pk (Note 1) |
39~48 Volts(DC) Shut down & latch off, o/p volt, re-power |
±2.0% (Note 2) |
87% |
|
|
1.1Amps@115VAC /0.55 Amps@230VAC |
48 Volts(DC) |
2 Amps |
200 mVpk-pk (Note 1) |
52~64 Volts(DC) Shut down & latch off, o/p volt, re-power |
±2.0% (Note 2) |
87% |
CLG-100 series
|
Input Specifications
General Specifications
Environmental Specifications
|
Output Specifications
Physical Specifications
Notes 1. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 2. Tolerance : includes set up tolerance, line regulation and load regulation. 3. Please refer to OLP characteristics. 4. Derating may be needed under low input voltages. Please check the derating curve for more details. 5. This is the maximum possible output current and power, over load protection may be activated slightly below this level to comply with the requirement of UL1310 class 2. 6. Constant current operation region is within 75% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please reconfirm special electrical requirements for some specific system design. 7. Safety and EMC design refer to EN60598-1, subject 8750(UL), CNS15233, GB7000.1, FCC part18.3. Please refer to OLP characteristics. All specifications are typical at nominal input, full load, and 25°C unless otherwise noted Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. |