Order by phone: 1-800-823-8082 / +1-508-964-6300 M-F 8:30am to 5:30pm EST

CLG100 100w LED/Lighting Power Supplies

100W Single Output Class 2 Switching Power Supply

Universal AC input / Full range

Built-in active PFC function

Protections: Short Circuit / Over voltage / Overload / Over temperature

IP67 design for indoor or outdoor installations

UL1310 Class 2 power unit

Cooling by free air convection

Model Number

Input Current

Output Voltage

Output Amps

Ripple and Noise

Over Voltage Protection

Voltage Tolerance

Efficiency

CLG-100-12

0.8Amps@115VAC / 0.4 Amps@230VAC

12 Volts(DC)

5 Amps

150 mVpk-pk (Note 1)

13~16 Volts(DC) Shut down & latch off, o/p volt, re-power

±3.0% (Note 2)

83%

CLG-100-15

0.9Amps@115VAC /0.45 Amps@230VAC

15 Volts(DC)

5 Amps

150 mVpk-pk (Note 1)

16.5~20 Volts(DC) Shut down & latch off, o/p volt, re-power

±3.0% (Note 2)

85%

CLG-100-20

1.1Amps@115VAC /0.55 Amps@230VAC

20 Volts(DC)

4.8 Amps

150 mVpk-pk (Note 1)

22~27 Volts(DC) Shut down & latch off, o/p volt, re-power

±3.0% (Note 2)

87%

CLG-100-24

1.1Amps@115VAC /0.55 Amps@230VAC

24 Volts(DC)

4 Amps

150 mVpk-pk (Note 1)

27~34 Volts(DC) Shut down & latch off, o/p volt, re-power

±3.0% (Note 2)

87%

CLG-100-27

1.1Amps@115VAC /0.55 Amps@230VAC

27 Volts(DC)

3.55 Amps

150 mVpk-pk (Note 1)

29~36 Volts(DC) Shut down & latch off, o/p volt, re-power

±3.0% (Note 2)

87%

CLG-100-36

1.1Amps@115VAC /0.55 Amps@230VAC

36 Volts(DC)

2.65 Amps

150 mVpk-pk (Note 1)

39~48 Volts(DC) Shut down & latch off, o/p volt, re-power

±2.0% (Note 2)

87%

CLG-100-48

1.1Amps@115VAC /0.55 Amps@230VAC

48 Volts(DC)

2 Amps

200 mVpk-pk (Note 1)

52~64 Volts(DC) Shut down & latch off, o/p volt, re-power

±2.0% (Note 2)

87%

CLG-100 series

Input Specifications

Input Voltage Range

90-264VAC ; 127~370Volts(DC) (Note 4)

Input Current

0.8Amps@115VAC / 0.4 Amps@230VAC

Frequency Range

47-63 Hz

Inrush Current

40 Amps @ 230VAC max (Cold start)

Leakage Current

< 0.75 mAmps @ 240VAC

DC Voltage Adjust (typ.)

Fixed. Can be modified between 0%~-15% rated output voltage

Power Factor Correction

PF>0.95/230VAC; /PF>0.95/115VAC @FL; PF? 0.9 at 75~100% load

General Specifications

Isolation

3750VAC Input - Output; 1880VAC Input - Ground; 500VAC Output - Ground

Efficiency

83%

Safety Approvals

UL1310 Class 2; EN61347-1, TUV EN60950-1, UL60950-1, EN61347-2-13 independent, UL879(listed in UL , Sign Components Manual (SAM)), CAN/CSA C22.2 No. 223-M91(except for 48V) (Note 7)

Insulation Resistance

I/P-O/P 100M? / 500VDC /25°C/70% RH

EMI

Compliance to EN55015; EN55022B(CISPR22B)

EMS

Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61547; EN55024, light industry level, (surge 4KV) criteria A

Harmonic Current

Compliance to EN610000-3-2 Class C (?75% load); EN61000-3-3

Environmental Specifications

Operating Temperature

-30°C to +70°C (See Derate Curve)

Storage Temperature

-40°C to +80°C, 10~95% RH

Relative Humidity

20~95% RH non cond

MTBF

301KHrs min, MIL-HDBK-217F(25°C)

Vibration

10~500Hz, 5G 12min./1cycle,. period for 72min, each along X, Y. Z axes

Cooling

free air convection

IP Rating

IP67

Temperature Coefficient

±0.03%/°C (0~50°C)

Output Specifications

Output Voltage

12 Volts(DC)

Output Amps

5 Amps

Load Regulation

±2.0%

Line Regulation

±1.0%

Ripple and Noise

150 mVpk-pk (Note 1)

Over Voltage Protection

13~16 Volts(DC) Shut down & latch off, o/p volt, re-power

Over Current Protection

95~102% Constant current limiting, auto recov

Over Temperature Protection

90°C±10°C (RTH2), shut down o/p voltage re-power

Short Circuit Protection

Hiccup mode, auto recov (Note 3)

Hold Up Time

60mS @ 230VAC / 30mS @ 115VAC

Rise Time

1200mS, 80ms @ 230VAC / 115VAC

Voltage Tolerance

±3.0% (Note 2)

Physical Specifications

Size (mm)

222.2 x 68 x 38.8 mm

Size (Inches)

8.75” x 2.68” x 1.53”

Weight (g)

1000g

Weight (oz)

35.27 oz

Notes

1. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

2. Tolerance : includes set up tolerance, line regulation and load regulation.

3. Please refer to OLP characteristics.

4. Derating may be needed under low input voltages. Please check the derating curve for more details.

5. This is the maximum possible output current and power, over load protection may be activated slightly below this level to comply with the requirement of UL1310 class 2.

6. Constant current operation region is within 75% ~100% rated output voltage. This is the suitable operation region for LED related applications,

but please reconfirm special electrical requirements for some specific system design.

7. Safety and EMC design refer to EN60598-1, subject 8750(UL), CNS15233, GB7000.1, FCC part18.3. Please refer to OLP characteristics.

All specifications are typical at nominal input, full load, and 25°C unless otherwise noted

Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.