BWS Open Frame Power Supplies
|
Model Number |
Output Voltage |
Output Amps |
Load Regulation |
Line Regulation |
Ripple and Noise |
Over Voltage Protection |
Over Current Protection |
Efficiency |
|
3.3VDC |
2 Amps |
±.0297V max |
±.0264V max |
83mV *3 |
Clamp, 3.8V, 115% of Rated Output Voltage |
2.2 Amps, 110% of Rated Output Current, Self Recovering *6 |
66% *2 |
|
|
5VDC |
2 Amps |
±.045V max |
±.04V max |
100mV *3 |
Clamp, 5.75V, 115% of Rated Output Voltage |
2.2 Amps, 110% of Rated Output Current, Self Recovering *6 |
74% *2 |
|
|
12VDC |
0.9 Amps |
±.108V max |
±.096V max |
170mV *3 |
Clamp, 13.8V, 115% of Rated Output Voltage |
0.99 Amps, 110% of Rated Output Current, Self Recovering *6 |
80% *2 |
|
|
15VDC |
0.7 Amps |
±.135V max |
±.12V max |
200mV *3 |
Clamp, 17.3V, 115% of Rated Output Voltage |
0.77 Amps, 110% of Rated Output Current, Self Recovering *6 |
80% *2 |
|
|
24VDC |
0.5 Amps |
±.216V max |
±.192V max |
290mV *3 |
Clamp, 27.6V, 115% of Rated Output Voltage |
0.55 Amps, 110% of Rated Output Current, Self Recovering *6 |
81% *2 |
BWS series
Input Specifications
Environmental Specifications
General Specifications |
Output Specifications
Physical Specifications
Notes 1. Ripple and Noise depend upon output voltage as specified per particular All specifications are typical at nominal input, full load, and 25°C unless otherwise noted Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. |