Order by phone: 1-800-823-8082 / +1-508-964-6300 M-F 8:30am to 5:30pm EST

BSL40 40 Watt Power Supplies

BSL40 40 Watt  Power Supplies

Up to 40W Output Power

Universal 90 to 264VAC Input

Single Outputs from 5VDC to 48VDC

High Efficiency up to 85%

3000V Isolation

1U Compatible Height

Model Number Output Voltage Output Amps Efficiency R&N p-p max. Capacitive Load
BSL40-5-A 5VDC 8 Amps 80%
100mV
23,000uF
BSL40-9-A 9VDC 4.4 Amps 80%
120mV
10,200uF
BSL40-12-A 12VDC 3.33 Amps 83%
150mV
4,000uF
BSL40-15-A 15VDC 2.66 Amps 83%
150mV
5,500uF
24VDC
1.66 Amps
83%
240mV
1,300uF
36VDC
1.1 Amps
83%
360mV
600uF
48VDC
0.83 Amps
85%
400mV
270uF

BSL40 series

Input Specifications

Input Voltage Range

90-264

Frequency Range

47-63Hz

Inrush Current (115/230 Vin)

30A / 60A typical*

Input Current (90/264 Vin)

1A / 0.4A

Leakage Current (264V/50Hz)

<0.25mA

Environmental Specifications

Operating Temperature

-10 to +70°C, See Derate

Storage Temperature

-25 to +85°C *

Relative Humidity

0-95%*

ESD

IEC61000-4-2

RS

IEC61000-4-3

EFT

IEC61000-4-4

Surge

IEC6100-4-5

CS

IEC61000-4-6

DIPS IEC61000-4-11
EMI EN55022B / CISPR 11 B
MTBF 196,000 Hrs; Mil Std 217, 25°C
Vibration 2G Peak, 10-500Hz, 3 Axis, 30 min
Drop Test 70 cm Height

General Specifications

Input-Out Isolation

3000VAC

Insulation Resistance

≥20MΩ; 500VDC, 1S I/P-O/P

Efficiency

See Selection Chart Above

Switching Frequency

65Khz, (fixed, typical)

Safety Approvals

UL/cUL: UL60950-1, Class II; TUV: EN60950-1, Class II; CE: EN60601-1-2, Class II; CB: IEC60950-1, Class II; CSA: C22.2 60950.1, Class II

Output Specifications

Voltage & Current (Note 3)

See Selection Chart Above

Turn On Delay Time

<1S

Rise Time

<30mS

Load Regulation (20%-FL)

±1% max.

Line Regulation (LL-HL)

±0.1% max.

Preset Accuracy (FL, 115Vin)

1%

Over-Shoot & Under-Shoot

<10% of O/P Voltage

Ripple and Noise (Note 1 & 4)

See Selection Chart Above

Over Voltage Protection

Latching re-power

Current Limit, Self Recovering

150% max., hiccup mode *

Short Circuit Protection

Latching, Auto Recover *

Hold Up Time (115V/60Hz)

8mS, typical

Capacitive Loading (Note 5)

See Selection Chart Above

Physical Specifications

Size (Inches)

2 x 4 x 1.17

Weight (oz)

5.61

Notes

* These are stress ratings. Exposure of the devices to any of these conditions may adversely affect long term reliability. Proper operation under conditions other than the standard operating conditions is neither warranteed nor implied.

All specifications are typical at nominal input, full load, and 25°C unless otherwise noted

1. Make all measurements directly at the pins of the supply.

2. Specified for free air convection cooling.

3. 115Vin minimum required for full load start up.

4. Measured by paralleling 47uF/EC and 0.1uF ceramic capacitors on the output at a 20MHz band-width.

5. The power supply should start up and operate normally into these capacitive loads within specified input voltage and output current ranges over the specified operating temperature range and according to Derate.

Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.