Model Number

Output Voltage

Output Amps

Output Amps 200 LFM

ASM365-12

12VDC w. 12V Auxillary

16.6 Amps (12V Auxillary 0.5 Amps)

31.25 Amps (12V Auxillary 0.5 Amps)

ASM365-24

24VDC w. 12V Auxillary

8.4 Amps (12V Auxillary 0.5 Amps)

15.62 Amps (12V Auxillary 0.5 Amps)

ASM365-48

48VDC w. 12V Auxillary

4.2 Amps (12V Auxillary 0.5 Amps)

7.81 Amps (12V Auxillary 0.5 Amps)

ASM365 series

Input Specifications

Input Voltage Range

90-264 / 170-370

Frequency Range

47-63Hz

Inrush Current

230VAC Cold Start

Input Current

4A @ 90VAC

Leakage Current

110/200uA

Power Factor Correction

0.98% min.

Input Fuse

2A Internal Line & Neutral

Under Voltage Lockout

80VAC Auto Recover

Environmental Specifications

Operating Temperature

-20 to +50°C FL Derate Linearly to 50% Load at 70°C *

Storage Temperature

-20 to +85°C *

Relative Humidity

95% Non Condensing

EMI

EN55022, EN60601-1-2 Class B, 4dB Margin

MTBF

185,000 Hrs, Mil Std 217, 25°C

Vibration

2G, 5-500Hz, 3 Axis

Cooling

200LFM >200W O/P Power

Drop Test

30G, Half Sine, 6 Axis

Voltage Fluctuation

EN61000-3-3

ESD

EN61000-4-2, 8KV Air, 6KV Contact

Radiated Field

EN61000-4-3, 3V/m, 80-2500MHz, 1kHz/2Hz 80% AM Modulation, Dwell Time is 3S for 2Hz Modulation, Dwell Time is 1S for 1Hz Modulation

EFT

EN61000-4-4, 2kV on AC and DC, 5kHz repetition 1kV on I/O

Surge

EN61000-4-5, 2kV CM, 1kV DM (min 5 surges at each phase angle)

Conducted RF

EN61000-4-6, 3Vrms, 0.15-80MHz, 1kHz/2Hz 80% AM Modulation

General Specifications

Isolation

4000VAC for 1 Minute

Isolation Input-Ground

1500VAC for 1 Minute

Isolation Output-Ground

500VAC for 1 Minute

Isolation Output-Output

100VDC for 1 Minute

Safety Approvals

EN60601-1, IEC60601, UL/cUL 60950-1

Output Specifications

Output Voltage

5VDC

Output Amps

25 Amps

Output Amps 200 LFM

40 Amps

Load Regulation

±1% V1; ±5% V2 (12V aux,)

Line Regulation

±0.1% 90-264VAC

Cross Regulation

±1% V1; ±15% V2 (12V aux,)

Preset Accuracy

±1% Main Output V1

Temperature Coefficient

±0.25mV/°C

Ripple and Noise

1% of Output; ±2% V2 (12V aux,) (pk-pk, 20Mhz BW)

Over Voltage Protection

Redundant Protection for Open Feedback *

Over Current Protection

110-130% Auto Recover*

Over Temperature Protection

Auto Recovery *

Transient Response

(50% Load Change) 10% Recover within 1mS

Short Circuit Protection

Auto Recovery *

Rise Time

1S/10mS

Hold Up Time

16mS

DC Voltage Adjust (typ.)

5% Main Output V1

Remote Sense

0.5V min (5V Only)

Physical Specifications

Size (mm)

76.2 x 127 x 33.78 mm

Size (Inches)

3” x 5” x 1.33”

Notes

* These are stress ratings. Exposure of the devices to any of these conditions may adversely affect long term reliability. Proper operation under conditions other than the standard operating conditions is neither warranteed nor implied.

All specifications are typical at nominal input, full load, and 25°C unless otherwise noted