Single Outputs with 12V Auxillary |
|
|
Universal 90 to 264VAC Input |
|
|
5VDC to 48VDC Outputs |
|
|
4,000VAC Input to Output Isolation |
|
|
Short Circuit Protection |
|
|
Full Safety Approvals |
ASM365 365w Power Supplies
|
Model Number |
Output Voltage |
Output Amps |
Output Amps 200 LFM |
|
12VDC w. 12V Auxillary |
16.6 Amps (12V Auxillary 0.5 Amps) |
31.25 Amps (12V Auxillary 0.5 Amps) |
|
|
24VDC w. 12V Auxillary |
8.4 Amps (12V Auxillary 0.5 Amps) |
15.62 Amps (12V Auxillary 0.5 Amps) |
|
|
48VDC w. 12V Auxillary |
4.2 Amps (12V Auxillary 0.5 Amps) |
7.81 Amps (12V Auxillary 0.5 Amps) |
ASM365 series
Input Specifications
|
Input Voltage Range |
90-264 / 170-370 |
|
Frequency Range |
47-63Hz |
|
Inrush Current |
230VAC Cold Start |
|
Input Current |
4A @ 90VAC |
|
Leakage Current |
110/200uA |
|
Power Factor Correction |
0.98% min. |
|
Input Fuse |
2A Internal Line & Neutral |
|
Under Voltage Lockout |
80VAC Auto Recover |
Environmental Specifications
|
Operating Temperature |
-20 to +50°C FL Derate Linearly to 50% Load at 70°C * |
|
Storage Temperature |
-20 to +85°C * |
|
Relative Humidity |
95% Non Condensing |
|
EMI |
EN55022, EN60601-1-2 Class B, 4dB Margin |
|
MTBF |
185,000 Hrs, Mil Std 217, 25°C |
|
Vibration |
2G, 5-500Hz, 3 Axis |
|
Cooling |
200LFM >200W O/P Power |
|
Drop Test |
30G, Half Sine, 6 Axis |
|
Voltage Fluctuation |
EN61000-3-3 |
|
ESD |
EN61000-4-2, 8KV Air, 6KV Contact |
|
Radiated Field |
EN61000-4-3, 3V/m, 80-2500MHz, 1kHz/2Hz 80% AM Modulation, Dwell Time is 3S for 2Hz Modulation, Dwell Time is 1S for 1Hz Modulation |
|
EFT |
EN61000-4-4, 2kV on AC and DC, 5kHz repetition 1kV on I/O |
|
Surge |
EN61000-4-5, 2kV CM, 1kV DM (min 5 surges at each phase angle) |
|
Conducted RF |
EN61000-4-6, 3Vrms, 0.15-80MHz, 1kHz/2Hz 80% AM Modulation |
General Specifications
|
Isolation |
4000VAC for 1 Minute |
|
Isolation Input-Ground |
1500VAC for 1 Minute |
|
Isolation Output-Ground |
500VAC for 1 Minute |
|
Isolation Output-Output |
100VDC for 1 Minute |
|
Safety Approvals |
EN60601-1, IEC60601, UL/cUL 60950-1 |
Output Specifications
|
Output Voltage |
5VDC |
|
Output Amps |
25 Amps |
|
Output Amps 200 LFM |
40 Amps |
|
Load Regulation |
±1% V1; ±5% V2 (12V aux,) |
|
Line Regulation |
±0.1% 90-264VAC |
|
Cross Regulation |
±1% V1; ±15% V2 (12V aux,) |
|
Preset Accuracy |
±1% Main Output V1 |
|
Temperature Coefficient |
±0.25mV/°C |
|
Ripple and Noise |
1% of Output; ±2% V2 (12V aux,) (pk-pk, 20Mhz BW) |
|
Over Voltage Protection |
Redundant Protection for Open Feedback * |
|
Over Current Protection |
110-130% Auto Recover* |
|
Over Temperature Protection |
Auto Recovery * |
|
Transient Response |
(50% Load Change) 10% Recover within 1mS |
|
Short Circuit Protection |
Auto Recovery * |
|
Rise Time |
1S/10mS |
|
Hold Up Time |
16mS |
|
DC Voltage Adjust (typ.) |
5% Main Output V1 |
|
Remote Sense |
0.5V min (5V Only) |
Physical Specifications
|
Size (mm) |
76.2 x 127 x 33.78 mm |
|
Size (Inches) |
3” x 5” x 1.33” |
Notes
* These are stress ratings. Exposure of the devices to any of these conditions may adversely affect long term reliability. Proper operation under conditions other than the standard operating conditions is neither warranteed nor implied.
All specifications are typical at nominal input, full load, and 25°C unless otherwise noted
Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.