Single Output from 3.3 to 24 VDC

Model Number

Output Voltage

Output Amps

ASM-1500

3.3 VDC

3.5 Amps

ASM-1501

5 VDC

3 Amps

ASM-1502

12 VDC

1.25 Amps

ASM-1503

15VDC

1 Amps

ASM-1505

24VDC

0.63 Amps

ASM15 series

Input Specifications

Input Voltage Range

90-264 VAC

Frequency Range

47-63 Hz

Inrush Current

20A @ 100VAC Input *; 40A @ 200VAC Input *

Environmental Specifications

Operating Temperature

-10 to +50°C(FL)

EMC

FCC/A, VDE 0871/A

Storage Temperature

-25 to +71°C *

Relative Humidity

8-90% Non Cond (95% Non-Oper.)

MTBF

180,000 Hrs, Mil Std 217, 25°C

Operating Altitude

5000 ft Above Sea Level, Derate to 40°C ambient @ 10,000 ft

General Specifications

Isolation

4000VAC

Isolation Input-Ground

2500VAC

Isolation Output-Ground

1000VAC

Efficiency

75%~78%, typ

Switching Frequency

100Khz, (fixed, typical)

Safety Approvals

UL60601-1, EN60601-1, IEC60601-1

Output Specifications

Output Voltage

3.3 VDC

Output Amps

3.5 Amps

Load Regulation

± 3% (20% to 100% Load)

Line Regulation

± 0.1~1%, typ

Preset Accuracy

1%

Temperature Coefficient

±0.03%/°C

Ripple and Noise

100mV Pk-Pk, typ

Over Voltage Protection

Clamp, 130-150% *

Over Temperature Protection

Latching, Cool and Repower

Short Circuit Protection

Continuous, self-recovering

Peak Load

3.8 Amps

Hold Up Time

20 mS, typ

DC Voltage Adjust (typ.)

± 6% of FS (Primary)

Physical Specifications

Size (mm)

76.2 x 53.34 x 21.59 mm

Size (Inches)

3” x 2.10” x 0.85”

Construction

Open Frame

Weight (g)

70g

Weight (oz)

2.5 oz

Notes