Order by phone: 1-800-823-8082 / +1-508-964-6300 M-F 8:30am to 5:30pm EST

ASL150 150w Power Supplies

Single Outputs with 12V Auxiliary

Universal 90 to 264VAC Input

5VDC to 48VDC Outputs

3,000VAC Input to Output Isolation

Short Circuit Protection

Full Safety Approvals

Model Number

Output Voltage

Output Amps

Output Amps 200 LFM

ASL150-5

5VDC w. 12V Auxiliary

16 Amps (12V Auxillary 0.5 Amps)

20 Amps (12V Auxillary 0.5 Amps)

ASL150-12

12VDC w. 12V Auxiliary

8.3 Amps (12V Auxillary 0.5 Amps)

13.3 Amps (12V Auxillary 0.5 Amps)

ASL150-24

24VDC w. 12V Auxiliary

4.16 Amps (12V Auxillary 0.5 Amps)

6.66 Amps (12V Auxillary 0.5 Amps)

ASL150-48

48VDC w. 12V Auxiliary

2.08 Amps (12V Auxillary 0.5 Amps)

3.33 Amps (12V Auxillary 0.5 Amps)

ASL150 series

Input Specifications

Input Voltage Range

90-264 / 170-370

Frequency Range

47-63Hz

Inrush Current

No Damage @ 230VAC Cold Start

Input Current

<2.5A @ 100VAC

Leakage Current

<275uA (120V I/P)

Power Factor Correction

0.98%

Input Fuse

3A Internal Line & Neutral

Harmonic Input Current

Meets EN61000-3-2

Under Voltage Lockout

80VAC Auto Recover

Environmental Specifications

Operating Temperature

-20 to +50°C FL Derate Linearly to 50% Load at 70°C *

EMC

EN55024

Storage Temperature

-40 to +80°C *

Relative Humidity

8-90% Non Cond (95% Non-Oper.)

Cooling

Convection Cooled: 150,000Hrs; Air Flow (200 CFM): 300,000 Hrs

Operating Altitude

5000 ft Above Sea Level, Derate to 40°C ambient @ 10,000 ft

Voltage Fluctuation

EN61000-3-3

ESD

15KV Air, 8KV Contact

Radiated Field

3V/m, 80-1000MHz 80% Modulation at distance of 3M

EFT

±2kV on AC power port for 1 minute; ±1kV on signal/ctrl lines

Surge

±1kV line to line/±2kV line to earth on AC power port; ±0.5kV for outdoor cables

Conducted RF

3V; 0.15-80MHz 80% Modulation

Voltage Variations

>95% dip, 0.5 period; 30% dip, 25 periods; >95% reduction, 250 periods

General Specifications

Isolation

3000VAC for 1 Minute

Isolation Input-Ground

1500VAC for 1 Minute

Isolation Output-Ground

500VAC for 1 Minute

Isolation Output-Output

100VDC for 1 Minute

Safety Approvals

EN60950, UL/CSA 60950

Output Specifications

Output Voltage

5VDC

Output Amps

16 / 20 Amps

Output Amps 200 LFM

0.5 / 0.5 Amps

Load Regulation

±1% V1; ±20% V2

Line Regulation

±0.1% 90-264VAC

Cross Regulation

±1% V1; ±15% V2

Preset Accuracy

±1% Main Output V1

Temperature Coefficient

±0.25mV/°C

Ripple and Noise

20Mhz BW, resistive load, with 22uF (tantalum) and 0.47uF (ceramic) parallel capacitors at POL 1% of Output (500mV, 12V aux.)

Over Voltage Protection

130% max.

Over Current Protection

130% max. Auto Recover*

Over Temperature Protection

Auto Recovery *

Start Up

500mS

Transient Response

(50% Load Change) 10% Recover within 1mS

Short Circuit Protection

Auto Recovery *

Rise Time

20mS

Hold Up Time

16mS

DC Voltage Adjust (typ.)

5% Main Output V1

Physical Specifications

Size (Inches)

2 x 4 x 1.08

Weight (oz)

5.7

Notes

* These are stress ratings. Exposure of the devices to any of these conditions may adversely affect long term reliability. Proper operation under conditions other than the standard operating conditions is neither warranteed nor implied.

All specifications are typical at nominal input, full load, and 25°C unless otherwise noted

Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.