Order by phone: 1-800-823-8082 / +1-508-964-6300 M-F 8:30am to 5:30pm EST

ASA30 30w Switch Mode Power Supplies

30W Switching Adapter with Interchangeable AC Plugs

Universal 90-264VAC Input

UL60950-1

RoHS Compliant

Interchangeable AC Input Plugs

High Efficiency

Model Number

Output Voltage

Output Amps

Load Regulation

Preset Accuracy

Efficiency

ASA30-0301

5

5.0

±6% (Note 4)

± 4% (Note 1)

70%

ASA30-0304

9

3.3

±3% (Note 4)

± 2% (Note 1)

73%

ASA30-0302

12

2.5

±2% (Note 4)

± 2% (Note 1)

76%

ASA30-0303

15

2.0

±2% (Note 4)

± 2% (Note 1)

78%

ASA30-0306

18

1.65

±2% (Note 4)

± 2% (Note 1)

78%

ASA30-0305

24

1.25

±2% (Note 4)

± 2% (Note 1)

80%

ASA30 series

Input Specifications

Input Voltage Range

90-264 VAC

Frequency Range

47-63 Hz

Inrush Current

50 Amps max. @ 264VAC

Input Current

0.8 Amps max.

Leakage Current

0.25mA max.

General Specifications

Isolation

I/P-O/P: 3000VAC

Efficiency

70%

Safety Approvals

UL60950-1, EN60950-1

Physical Specifications

Size (Inches)

4.24” x2.27” x 1.32”

Mounting and Connection

2.1x5.5x12mm Coax

Construction

Wallmount Style

Weight (g)

300g

Weight (oz)

10.58oz

Output Specifications

Output Voltage

5

Output Amps

5

Load Regulation

±6% (Note 4)

Line Regulation

± 1% (Note 3)

Preset Accuracy

± 4% (Note 1)

Ripple and Noise

± 1% (Note 2)

Over Voltage Protection

Yes

Short Circuit Protection

Continuous, Auto Recovery

Hold Up Time

10mS typ. @ 115VAC

Environmental Specifications

Operating Temperature

0 to +40°C FL

Storage Temperature

-20 to +85°C

EMI

CISPR/FCC Class B

Notes

1. Voltage Setpoint at 60% Load

2. Add a 0.1uF ceramic capacitor and a 10uF E.L. capacitor to output for Ripple & Noise measuring @ 20MHz BW.

3. Line Regulation measured from 00VAC to 240VAC, full load. 4. Load Regulation measured from 60% to full oad and from 60% to 20

% load (60% ±40%)

5. Minimum load is not required for proper operation.

All specifications are typical at nominal input, full load, and 25°C unless otherwise noted

Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.