25W Single Output Switching Power Supply
AS25DRL 25w Switch Mode Power Supplies
|
Universal AC input/Full range |
|
|
Protections: Short circuit/Over load/Over voltage |
|
|
Cooling by free air convection |
|
|
100% full load burn-in test |
|
|
Fixed switching frequency at 56KHz |
|
|
Model Number |
Output Voltage |
Output Amps |
Load Regulation |
Ripple and Noise |
Over Voltage Protection |
Voltage Tolerance |
DC Voltage Adjust |
Minimum Load Requirement |
Efficiency |
|
5V |
5A |
+/- 1.0% |
50MvP-P max. (Note 2) |
5.75v ~ 6.75v Hiccup mode, recovers automatically after fault condition is removed |
+/- 2.0% (Note 3) |
4.75 ~ 5.5V |
0 ~ 5A |
72% / 115VAC typ. |
|
|
12V |
2.1A |
+/- 0.5% |
100mVp-p max. (Note 2) |
13.8V ~ 16.2V Hiccup mode, recovers automatically after fault condition is removed |
+/- 1.0% (Note 3) |
10.8 ~ 13.2V |
0 ~ 2.1A |
76% / 115VAC typ. |
|
|
15V |
1.7A |
+/- 0.5% |
100mVp-p max. (Note 2) |
17.25V ~ 20.25V Hiccup mode, recovers automatically after fault condition is removed |
+/- 1.0% (Note 3) |
13.5 ~ 16.5V |
0 ~ 1.7A |
77% / 115VAC typ. |
|
|
24V |
1.1A |
+/- 0.5% |
100mVp-p max. (Note 2) |
27.6V ~ 32.4V Hiccup mode, recovers automatically after fault condition is removed |
+/- 1.0% (Note 3) |
21.6 ~ 26.4V |
0 ~ 1.1A |
80% / 115VAC typ |
AS25/DRL series
|
Input Specifications
General Specifications
Environmental Specifications
|
Output Specifications
Physical Specifications
Notes 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 °C of ambient temperature. 2. Ripple and noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equpiment must be re-confirmed that it still meets EMC directives. All specifications are typical at nominal input, full load, and 25°C unless otherwise noted Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. |