Order by phone: 1-800-823-8082 / +1-508-964-6300 M-F 8:30am to 5:30pm EST

AS25 25w 25 Watt Switch Mode Power Supplies

25W Single Output Switching Power Supply

Universal AC input/Full range

Protections: Short circuit/Over load/Over voltage

Cooling by free air convection

100% full load burn-in test

Fixed switching frequency at 56KHz

Model Number

Output Voltage

Output Amps

Load Regulation

Ripple and Noise

Over Voltage Protection

DC Voltage Adjust (typ.)

Efficiency

AS25-5

5V

5A

±1.0

50mVp-p max. (note 2)

5.75~6.75V hiccup mode, recovers automatically after fault condition is removed

4.75~5.5V

72%/115VAC typ.

AS25-12

12V

2.1A

±0.5

100mVp-p max. (note 2)

13.8~16.2V hiccup mode, recovers automatically after fault condition is removed

10.8~13.2V

76%/115VAC typ.

AS25-15

15V

1.7A

±0.5

100mVp-p max. (note 2)

17.25~20.25V hiccup mode, recovers automatically after fault condition is removed

13.5~16.5V

77%/115VAC typ.

AS25-24

24V

1.1A

±0.5

100mVp-p max. (note 2)

27.6~32.4V hiccup mode, recovers automatically after fault condition is removed

21.6~26.4V

80%/115VAC typ.

AS25 series

Input Specifications

Input Voltage Range

85~264VAC 120~370VDC

Frequency Range

47~63Hz

Inrush Current

Cold Start 13A/115VAC 25A/230VAC

General Specifications

Isolation

4242VDC

Isolation Input-Ground

2121VDC

Isolation Output-Ground

707VDC

Insulation Resistance

72%/115VAC typ.

Switching Frequency

UL1012, TUV EN60950-1 Approved

Environmental Specifications

Operating Temperature

-10~+60°C (refer to output load derating curve)

Storage Temperature

-20~+85°C

Relative Humidity

20~90% RH non-condensing

EMI

Compliance to EN55022 (CISPR22) Class B

MTBF

330.8K hrs min. MIL-HDBK-217F (25°C)

EMS

Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A

Output Voltage

5V

Output Amps

5A

Load Regulation

±1.0

Line Regulation

±0.5

Temperature Coefficient

0.3%/°C (0~50°C)

Ripple and Noise

50mVp-p max. (note 2)

Over Voltage Protection

5.75~6.75V hiccup mode, recovers automatically after fault condition is removed

Over Current Protection

105~150% rated out put power, hiccup mode, recovers automatically after fault condition is removed

DC Voltage Adjust (typ.)

4.75~5.5V

Hold Up Time

90mS/230VAC 12mS/115VAC at full load typ.

Physical Specifications

Size (mm)

99x97x36mm

Size (Inches)

3.90”x3.82”x 1.42”

Weight (g)

390g; 45pcs/18000g/0.9CUFT

Notes

Output Specifications

1. All paramterers NOT specially mentioned are measure at 230VAC input, rated load and 25°C of ambient temperature.

2. Ripple and noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf and 47uf parallell capacitor.

3. Tolerance: includes set up tolerance, line regulation and load regulation.

4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.

All specifications are typical at nominal input, full load, and 25°C unless otherwise noted

Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.