AS150DRL 150 Watt DIN Rail Mount Switch Mode Enclosed Power Supplies
|
AC input range selectable by switch |
|
|
Protections: Short circuit/Over load/Over voltage |
|
|
Cooling by free air convection |
|
|
100% full load burn-in test |
|
|
Fixed switching frequency at 25KHz |
|
|
Model Number |
Output Voltage |
Output Amps |
Load Regulation |
Line Regulation |
Ripple and Noise |
Over Voltage Protection |
Voltage Tolerance |
DC Voltage Adjust |
Minimum Load Requirement |
Efficiency |
| AS150-5/DRL | 5V | 30A |
+/- 0.5% |
+/- 0.5% |
150mVp-p max. (Note 2) |
5.75 ~ 6.75V Shut down o/p voltage, re-power on to recover |
+/- 2.0% (Note 3) |
4.5 ~ 5.5V |
0 ~ 30A |
78% typ. |
| AS150-7.5/DRL | 7.5V | 20A |
+/- 0.5% |
+/- 0.5% |
150mVp-p max. (Note 2) |
8.63 ~ 10.13V Shut down o/p voltage, re-power on to recover |
+/- 1.0% (Note 3) |
6 ~ 8.3V |
0 ~ 20A |
80% typ. |
| AS150-9/DRL | 9V | 16.7A |
+/- 0.3% |
+/- 0.3% |
180mVp-p max. (Note 2) |
10.35 ~ 12.2V Shut down o/p voltage, re-power on to recover |
+/- 1.0% (Note 3) |
8 ~ 10.4V |
0 ~ 16.7A |
80% typ. |
| AS150-12/DRL | 12V | 12.5A |
+/- 0.3% |
+/- 0.3% |
180mVp-p max. (Note 2) |
13.8 ~ 16.2V Shut down o/p voltage, re-power on to recover |
+/- 1.0% (Note 3) |
10.6 ~ 13.2V |
0 ~ 12.5A |
82% typ. |
| AS150-13.5/DRL | 13.5V | 11.2A |
+/- 0.3% |
+/- 0.3% |
180mVp-p max. (Note 2) |
15.53 ~ 18.2V Shut down o/p voltage, re-power on to recover |
+/- 1.0% (Note 3) |
12 ~ 15V |
0 ~ 11.2A |
83% typ. |
| AS150-15/DRL | 15V | 10A |
+/- 0.3% |
+/- 0.3% |
180mVp-p max. (Note 2) |
17.25 ~ 20.3V Shut down o/p voltage, re-power on to recover |
+/- 1.0% (Note 3) |
13.5 ~ 16.5V |
0 ~ 10A |
84% typ. |
| AS150-24/DRL | 24V | 6.5A |
+/- 0.2% |
+/- 0.2% |
240mVp-p max. (Note 2) |
30 ~ 34.8V Shut down o/p voltage, re-power on to recover |
+/- 1.0% (Note 3) |
21 ~ 28V |
0 ~ 6.5A |
85% typ. |
| AS150-27/DRL | 27V | 5.6A |
+/- 0.2% |
+/- 0.2% |
240mVp-p max. (Note 2) |
31.1 ~ 36.45V Shut down o/p voltage, re-power on to recover |
+/- 1.0% (Note 3) |
24 ~ 30V |
0 ~ 5.6A |
86% typ. |
| AS150-48/DRL | 48V | 3.2A |
+/- 0.2% |
+/- 0.2% |
240mVp-p max. (Note 2) |
55.2 ~ 64.8V Shut down o/p voltage, re-power on to recover |
+/- 1.0% (Note 3) |
43 ~ 53V |
0 ~ 3.2A |
87% typ. |
AS150/DRL series
|
Input Specifications
General Specifications
Environmental Specifications
|
Output Specifications
Physical Specifications
Notes 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 °C of ambient temperature. 2. Ripple and noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equpiment must be re-confirmed that it still meets EMC directives. All specifications are typical at nominal input, full load, and 25°C unless otherwise noted Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. |