Order by phone: 1-800-823-8082 / +1-508-964-6300 M-F 8:30am to 5:30pm EST

AS150DRL 150 Watt DIN Rail Mount Switch Mode Enclosed Power Supplies

150W Single Output Switching Power Supply

AC input range selectable by switch

Protections: Short circuit/Over load/Over voltage

Cooling by free air convection

100% full load burn-in test

Fixed switching frequency at 25KHz

Model Number

Output Voltage

Output Amps

Load Regulation

Line Regulation

Ripple and Noise

Over Voltage Protection

Voltage Tolerance

DC Voltage Adjust

Minimum Load Requirement

Efficiency

AS150-5/DRL 5V 30A

+/- 0.5%

+/- 0.5%

150mVp-p max. (Note 2)

5.75 ~ 6.75V Shut down o/p voltage, re-power on to recover

+/- 2.0% (Note 3)

4.5 ~ 5.5V

0 ~ 30A

78% typ.

AS150-7.5/DRL 7.5V 20A

+/- 0.5%

+/- 0.5%

150mVp-p max. (Note 2)

8.63 ~ 10.13V Shut down o/p voltage, re-power on to recover

+/- 1.0% (Note 3)

6 ~ 8.3V

0 ~ 20A

80% typ.

AS150-9/DRL 9V 16.7A

+/- 0.3%

+/- 0.3%

180mVp-p max. (Note 2)

10.35 ~ 12.2V Shut down o/p voltage, re-power on to recover

+/- 1.0% (Note 3)

8 ~ 10.4V

0 ~ 16.7A

80% typ.

AS150-12/DRL 12V 12.5A

+/- 0.3%

+/- 0.3%

180mVp-p max. (Note 2)

13.8 ~ 16.2V Shut down o/p voltage, re-power on to recover

+/- 1.0% (Note 3)

10.6 ~ 13.2V

0 ~ 12.5A

82% typ.

AS150-13.5/DRL 13.5V 11.2A

+/- 0.3%

+/- 0.3%

180mVp-p max. (Note 2)

15.53 ~ 18.2V Shut down o/p voltage, re-power on to recover

+/- 1.0% (Note 3)

12 ~ 15V

0 ~ 11.2A

83% typ.

AS150-15/DRL 15V 10A

+/- 0.3%

+/- 0.3%

180mVp-p max. (Note 2)

17.25 ~ 20.3V Shut down o/p voltage, re-power on to recover

+/- 1.0% (Note 3)

13.5 ~ 16.5V

0 ~ 10A

84% typ.

AS150-24/DRL 24V 6.5A

+/- 0.2%

+/- 0.2%

240mVp-p max. (Note 2)

30 ~ 34.8V Shut down o/p voltage, re-power on to recover

+/- 1.0% (Note 3)

21 ~ 28V

0 ~ 6.5A

85% typ.

AS150-27/DRL 27V 5.6A

+/- 0.2%

+/- 0.2%

240mVp-p max. (Note 2)

31.1 ~ 36.45V Shut down o/p voltage, re-power on to recover

+/- 1.0% (Note 3)

24 ~ 30V

0 ~ 5.6A

86% typ.

AS150-48/DRL 48V 3.2A

+/- 0.2%

+/- 0.2%

240mVp-p max. (Note 2)

55.2 ~ 64.8V Shut down o/p voltage, re-power on to recover

+/- 1.0% (Note 3)

43 ~ 53V

0 ~ 3.2A

87% typ.

AS150/DRL series

Input Specifications

Input Voltage Range

88 ~ 132VAC/176 ~ 264VAC selected by jumper or switch 248 ~ 370VDC

Frequency Range

47 ~ 63Hz

Inrush Current

Cold Start 35A typ.

Input Current

3.2A/115VAC 1.6A/230VAC typ.

Leakage Current

<3.5mA / 240 VAC

General Specifications

Isolation

3KVAC

Isolation Input-Ground

1.5KVAC

Isolation Output-Ground

0.5KVAC

Insulation Resistance

100M Ohms/500VDC

Efficiency

78% typ.

Safety Approvals

UL1012, UL60950-1, TUV EN60950-1 Approved

Harmonic Current

Compliance to EN61000-3-2,-3

Environmental Specifications

Operating Temperature

-10°C ~ +60°C (Refer to output load for derating curve)

Storage Temperature

-20°C ~ +85°C

Working Humidity

20~90% RH non condensing

Storage Humidity

10 ~ 95% RH

EMI

Compliance to EN 55022 (CISPR22) Class B

MTBF

286.7K hrs min. MIL-HDBK-217F (25°C)

Vibration

10 ~ 500Hz. 2G 10- min./1 cycle, 60min. Each along X, Y, Z axes

EMS

Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A

Output Specifications

Output Voltage

5V

Output Amps

30A

Load Regulation

± 0.5%

Line Regulation

± 0.5%

Temperature Coefficient

±0.03%/°C (0 ~ 50°C)

Ripple and Noise

150mVp-p max. (Note 2)

Over Voltage Protection

5.75 ~ 6.75V Shut down o/p voltage, re-power on to recover

Over Current Protection

105 ~ 150% rated output power Shut down o/p voltage, re-power on to recover

Voltage Tolerance

± 2.0% (Note 3)

DC Voltage Adjust

4.5 ~ 5.5V

Minimum Load Requirement

0 ~ 30A

Rise Time

100ms, 50ms at full load

Hold Up Time

28ms at full load typ.

Physical Specifications

Size (mm)

199x110x50mm

Size (Inches)

7.8x4.3x1.9”

Weight (g)

0.8KG; 16pcs/13.8KG/0.95CUFT

Notes

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 °C of ambient temperature.

2. Ripple and noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance: includes set up tolerance, line regulation and load regulation.

4. The power supply is considered a component which will be installed into a final equipment. The final equpiment must be re-confirmed that it still meets EMC directives.

All specifications are typical at nominal input, full load, and 25°C unless otherwise noted

Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.