Order by phone: 1-800-823-8082 / +1-508-964-6300 M-F 8:30am to 5:30pm EST

AS150 150w Switch Mode Power Supplies

150W Single Output Switching Power Supply

AC input range selectable by switch

Protections: Short Circuit/Over load/Over voltage

Cooling by free air convection

100% full load burn-in test

Fixed switching frequency at 25KHz

Model Number

Output Voltage

Output Amps

Load Regulation

Line Regulation

Ripple and Noise

Over Voltage Protection

DC Voltage Adjust (typ.)

Efficiency

AS150-5

5V

30A

±0.5

±0.5

150mVp-p max. (note 2)

5.75~6.75 shut down o/p voltage, re-power on to recover

4.5~5.5V

78% typ.

AS150-7.5

7.5V

20A

±0.5

±0.5

150mVp-p max. (note 2)

8.63~10.13V shut down o/p voltage, re-power on to recover

6~8.3V

80% typ.

AS150-9

9V

16.7A

±0.5

±0.5

180mVp-p max. (note 2)

10.35~12.2V shut down o/p voltage, re-power on to recover

8~10.4V

80% typ.

AS150-12

12V

12.5A

±0.3

±0.3

180mVp-p max. (note 2)

13.8~16.2V shut down o/p voltage, re-power on to recover

10.6~13.2V

82% typ.

AS150-13.5

13.5V

11.2A

±0.3

±0.3

180mVp-p max. (note 2)

15.53~18.2V shut down o/p voltage, re-power on to recover

12~15V

83% typ.

AS150-15

15V

10A

±0.3

±0.3

180mVp-p max. (note 2)

17.25~20.3V shut down o/p voltage, re-power on to recover

13.5~16.5V

84% typ.

AS150-24

24V

6.5A

±0.2

±0.2

240mVp-p max. (note 2)

30~34.8V shut down o/p voltage, re-power on to recover

21~28V

85% typ.

AS150-27

27V

5.6A

±0.2

±0.2

240mVp-p max. (note 2)

31.1~36.45V shut down o/p voltage, re-power on to recover

24~30V

86% typ.

AS150-48

48V

3.2A

±0.2

±0.2

240mVp-p max. (note 2)

55.2~64.8V shut down o/p voltage, re-power on to recover

43~53V

87% typ.

AS150 series

Input Specifications

Input Voltage Range

88~132VAC/176~264VAC selected switch 248~370VDC

Frequency Range

47~63Hz

Inrush Current

Cold Start 35A typ.

General Specifications

Isolation

4242VDC

Isolation Input-Ground

2121VDC

Isolation Output-Ground

707VDC

Insulation Resistance

78% typ.

Switching Frequency

UL1012, UL1950-1, TUV EN60950-1 Approved

Environmental Specifications

Operating Temperature

-10~+60°C (refer to output load derating curve)

Storage Temperature

-20~+85°C

Relative Humidity

20~90% RH non-condensing

EMI

Compliance to EN55022 (CISPR22) Class B

MTBF

286.7K hrs min. MIL-HDBK-217F (25°C)

EMS

Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A

Output Voltage

5V

Output Amps

30A

Load Regulation

±0.5

Line Regulation

±0.5

Temperature Coefficient

0.3%/°C (0~50°C)

Ripple and Noise

150mVp-p max. (note 2)

Over Voltage Protection

5.75~6.75 shut down o/p voltage, re-power on to recover

Over Current Protection

105~150% rated out put power, shut down o/p voltage, re-power on to recover

DC Voltage Adjust (typ.)

4.5~5.5V

Hold Up Time

28mS at full load typ.

Physical Specifications

Size (mm)

199x110x50mm

Size (Inches)

7.83”x4.33”x 1.97”

Weight (g)

800g; 16pcs/13800g/095CUFT

Notes

1. All paramterers NOT specially mentioned are measure at 230VAC input, rated load and 25°C of ambient temperature.

2. Ripple and noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf and 47uf parallell capacitor.

3. Tolerance: includes set up tolerance, line regulation and load regulation.

4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.

All specifications are typical at nominal input, full load, and 25°C unless otherwise noted

Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.

Output Specifications