150W Single Output Switching Power Supply
AS150 150w Switch Mode Power Supplies
|
AC input range selectable by switch |
|
|
Protections: Short Circuit/Over load/Over voltage |
|
|
Cooling by free air convection |
|
|
100% full load burn-in test |
|
|
Fixed switching frequency at 25KHz |
|
Model Number |
Output Voltage |
Output Amps |
Load Regulation |
Line Regulation |
Ripple and Noise |
Over Voltage Protection |
DC Voltage Adjust (typ.) |
Efficiency |
|
5V |
30A |
±0.5 |
±0.5 |
150mVp-p max. (note 2) |
5.75~6.75 shut down o/p voltage, re-power on to recover |
4.5~5.5V |
78% typ. |
|
|
7.5V |
20A |
±0.5 |
±0.5 |
150mVp-p max. (note 2) |
8.63~10.13V shut down o/p voltage, re-power on to recover |
6~8.3V |
80% typ. |
|
|
9V |
16.7A |
±0.5 |
±0.5 |
180mVp-p max. (note 2) |
10.35~12.2V shut down o/p voltage, re-power on to recover |
8~10.4V |
80% typ. |
|
|
12V |
12.5A |
±0.3 |
±0.3 |
180mVp-p max. (note 2) |
13.8~16.2V shut down o/p voltage, re-power on to recover |
10.6~13.2V |
82% typ. |
|
|
13.5V |
11.2A |
±0.3 |
±0.3 |
180mVp-p max. (note 2) |
15.53~18.2V shut down o/p voltage, re-power on to recover |
12~15V |
83% typ. |
|
|
15V |
10A |
±0.3 |
±0.3 |
180mVp-p max. (note 2) |
17.25~20.3V shut down o/p voltage, re-power on to recover |
13.5~16.5V |
84% typ. |
|
|
24V |
6.5A |
±0.2 |
±0.2 |
240mVp-p max. (note 2) |
30~34.8V shut down o/p voltage, re-power on to recover |
21~28V |
85% typ. |
|
|
27V |
5.6A |
±0.2 |
±0.2 |
240mVp-p max. (note 2) |
31.1~36.45V shut down o/p voltage, re-power on to recover |
24~30V |
86% typ. |
|
|
48V |
3.2A |
±0.2 |
±0.2 |
240mVp-p max. (note 2) |
55.2~64.8V shut down o/p voltage, re-power on to recover |
43~53V |
87% typ. |
AS150 series
|
Input Specifications
General Specifications
Environmental Specifications
|
Physical Specifications
Notes 1. All paramterers NOT specially mentioned are measure at 230VAC input, rated load and 25°C of ambient temperature. 2. Ripple and noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf and 47uf parallell capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. All specifications are typical at nominal input, full load, and 25°C unless otherwise noted Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. Output Specifications |