AS100FDRL 100 Watt Switch Mode Power Supplies

100W Single Output Switching Power Supply

AC input range selectable by switch

Protections: Short circuit/Over load/Over voltage

Cooling by free air convection

100% full load burn-in test

Fixed frequency at 83KHz

Model Number

Output Voltage

Output Amps

Load Regulation

Ripple and Noise

Over Voltage Protection

Voltage Tolerance

DC Voltage Adjust

Minimum Load Requirement

Efficiency

AS100F-5/DRL

5V

20A

+/- 1.0%

100mVp-p max. (Note 2)

5.75 ~ 6.75V Hiccup mode, recovers automatically after fault condition is removed

+/- 2.0% (Note 3)

4.5 ~ 5.5V

0 ~ 20A

76% typ.

AS100F-7.5/DRL

7.5V

13.5A

+/- 0.5%

125mVp-p max. (Note 2)

8.63 ~ 10.13V Hiccup mode, recovers automatically after fault condition is removed

+/- 1.0% (Note 3)

6.75 ~ 8.25V

0 ~ 13.5A

78% typ.

AS100F-12/DRL

12V

8.5A

+/- 0.5%

125mVp-p max. (Note 2)

13.8 ~ 16.2V Hiccup mode, recovers automatically after fault condition is removed

+/- 1.0% (Note 3)

10.8 ~ 13.2V

0 ~ 8.5A

80% typ.

AS100F-15/DRL

15V

6.7A

+/- 0.5%

125mVp-p max. (Note 2)

17.25 ~ 20.25V Hiccup mode, recovers automatically after fault condition is removed

+/- 1.0% (Note 3)

13.5 ~ 16.5V

0 ~ 6.7A

81% typ.

AS100F-24/DRL

24V

4.5A

+/- 0.5%

150mVp-p max. (Note 2)

27.6 ~ 32.4V Hiccup mode, recovers automatically after fault condition is removed

+/- 1.0% (Note 3)

21.6 ~ 26.4V

0 ~ 4.5A

83% typ.

AS100F-48/DRL

48V

2.2A

+/- 0.5%

150mVp-p max. (Note 2)

55.2 ~ 64.8V Hiccup mode, recovers automatically after fault condition is removed

+/- 1.0% (Note 3)

43.2 ~ 52.8V

0 ~ 2.2A

84% typ.

AS100F/DRL series

Input Specifications

Input Voltage Range

88 ~ 132VAC/176 ~ 264VAC selected by jumper or switch 248 ~ 370VDC

Frequency Range

47 ~ 63Hz

Inrush Current

Cold Start 20A/115VAC 1.5A/230VAC typ.

Input Current

3.15A/115VAC 1.5A/230VAC typ.

Leakage Current

<1mA / 240VAC

General Specifications

Isolation

3KVAC

Isolation Input-Ground

1.5KVAC

Isolation Output-Ground

0.5KVAC

Insulation Resistance

100M Ohms/500VDC

Efficiency

76% typ.

Safety Approvals

CSA60950-1 (for 24v only); UL1012; TUV EN60950-1;

Harmonic Current

Compliance to EN61000-3-2,-3

Environmental Specifications

Operating Temperature

-10°C ~ +60°C (Refer to output load for derating curve)

Storage Temperature

-20°C ~ +85°C

Working Humidity

20~90% RH non-condensing

Storage Humidity

10 ~ 95% RH

EMI

Compliance to EN 55022 (CISPR22) Class B

MTBF

314.9K hrs min MIL-HDBK-217F (25°C)

Vibration

10 ~ 500Hz. 2G 10- min./1 cycle, 60min. Each along X, Y, Z axes

EMS

Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A

Output Specifications

Output Voltage

5V

Output Amps

20A

Load Regulation

± 1.0%

Line Regulation

± 0.5%

Temperature Coefficient

± 0.03% / °C (0~50°C)

Ripple and Noise

100mVp-p max. (Note 2)

Over Voltage Protection

5.75 ~ 6.75V Hiccup mode, recovers automatically after fault condition is removed

Over Current Protection

105 ~ 150% rated output power Hiccup mode, recovers automatically after fault condition is removed

Voltage Tolerance

± 2.0% (Note 3)

DC Voltage Adjust

4.5 ~ 5.5V

Minimum Load Requirement

0 ~ 20A

Rise Time

1000ms, 30ms at fulll load

Hold Up Time

20ms at full load

Physical Specifications

Size (mm)

199x98x38 mm

Size (Inches)

7.8x3.8x1.5”

Weight (g)

0.65Kg; 20pcs/14.2Kg/0.8CUFT

Notes

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 °C of ambient temperature.

2. Ripple and noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance: includes set up tolerance, line regulation and load regulation.

4. The power supply is considered a component which will be installed into a final equipment. The final equpiment must be re-confirmed that it still meets EMC directives.

All specifications are typical at nominal input, full load, and 25°C unless otherwise noted

Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.