AS100F 100 Watt Power Supplies
|
AC input range selectible by switch |
|
|
Protections: Short Circuit/Over load/Over voltage |
|
|
Cooling by free air convection |
|
|
100% full load burn-in test |
|
|
Fixed switching frequency at 83KHz |
|
Model Number |
Output Voltage |
Output Amps |
Load Regulation |
Ripple and Noise |
Over Voltage Protection |
DC Voltage Adjust (typ.) |
Efficiency |
|
5V |
20A |
±1.0 |
100mVp-p max. (note 2) |
5.75~6.75V hiccup mode, recovers automatically after fault condition is removed |
4.5~5.5VDC |
76% |
|
|
7.5V |
13.5A |
±0.5 |
125mVp-p max. (note 2) |
8.63~10.13V hiccup mode, recovers automatically after fault condition is removed |
6.75~8.25VDC |
78% |
|
|
12V |
8.5A |
±0.5 |
125mVp-p max. (note 2) |
13.8~16.2V hiccup mode, recovers automatically after fault condition is removed |
10.8~13.2VDC |
80% |
|
|
15V |
6.7A |
±0.5 |
125mVp-p max. (note 2) |
17.25~20.25V hiccup mode, recovers automatically after fault condition is removed |
13.5~16.5VDC |
81% |
|
|
24V |
4.5A |
±0.5 |
150mVp-p max. (note 2) |
27.6~32.4V hiccup mode, recovers automatically after fault condition is removed |
21.6~26.4VDC |
83% |
|
|
48V |
2.2A |
±0.5 |
150mVp-p max. (note 2) |
55.2~64.8V hiccup mode, recovers automatically after fault condition is removed |
43.2~52.8VDC |
84% |
AS100F series
|
Input Specifications
Physical Specifications
General Specifications
|
Output Specifications
Environmental Specifications
Notes 1. All paramterers NOT specially mentioned are measure at 230VAC input, rated load and 25°C of ambient temperature. 2. Ripple and noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf and 47uf parallell capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. All specifications are typical at nominal input, full load, and 25°C unless otherwise noted Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. |