Order by phone: 1-800-823-8082 / +1-508-964-6300 M-F 8:30am to 5:30pm EST

ANC Power Supplies

AC-DC Power Module

Switching Power Module for PCB Mount

Fully Encapsulated Plastic Case

Universal Input Range 90-264VAC, 47-440 Hz

Regulated Output

Low Ripple and Noise

Model Number

Output Voltage

Output Amps

Load Regulation

Line Regulation

Preset Accuracy

Efficiency

ANC-5S

5V

3.0

±0.5% 5-100% typ.

±0.5% LL-HL typ.

±2%

70%

ANC-12S

12V

1.25

±0.5% 5-100% typ.

±0.5% LL-HL typ.

±2%

73%

ANC-15S

15V

1.0

±0.5% 5-100% typ.

±0.5% LL-HL typ.

±2%

73%

ANC-24S

24V

0.625

±0.5% 5-100% typ.

±0.5% LL-HL typ.

±2%

77%

ANC-5D

±5VDC

±1.5

±3% 5-100% typ.

±0.5% LL-HL typ.

±5%

71%

ANC-12D

±12VDC

±0.65

±3% 5-100% typ.

±0.5% LL-HL typ.

±5%

76%

ANC-15D

±15VDC

±0.5

±3% 5-100% typ.

±0.5% LL-HL typ.

±5%

65%

ANC-5S12D

5/±12VDC

2.0/±0.2

±2% / ±5% 5-100% typ.

±1% / ±5% LL-HL typ.

±2%

68%

ANC-5S15D

5/±15VDC

2.0/±0.15

±2% / ±5% 5-100% typ.

±1% / ±5% LL-HL typ.

±2%

68%

ANC series

Input Specifications

Input Voltage Range

90-264 VAC or 120-370 VDC

Frequency Range

47-440 Hz

Inrush Current

10 A max. (115 VAC) / 20 A max. (230 VAC)

Environmental Specifications

Operating Temperature

-25°C…+70°C (with derating)

Storage Temperature

-40°C…+85°C

Relative Humidity

95% RH

EMI

EN 55022 class B

MTBF

>200,000 h @ 25°C (MIL-HDBK-217F)

EMS

EN 55024

Physical Specifications

Size (mm)

74.0 x 54.0 x 22.0 mm

Size (Inches)

2.91 x 2.13 x 0.87 Inches

Case Material

Plastic resin with Fiberglass (flammability to UL 94V-0)

Weight (g)

140g

Output Specifications

Output Voltage

5V

Output Amps

3.0

Load Regulation

±0.5% 5-100% typ.

Line Regulation

±0.5% LL-HL typ.

Preset Accuracy

±2%

Temperature Coefficient

±0.02%/°C

Ripple and Noise

<0.2% Vout +40mV max (Vp-p) / <0.5% Vout +50mV max (Vp-p)

Over Voltage Protection

Zener diode clamp

Short Circuit Protection

Hiccup mode, indefinite (automatic recovery)

Hold Up Time

15 ms min.

General Specifications

Isolation

3000V

Efficiency

70%

Switching Frequency

100 kHz

Safety Approvals

UL/cUL, CE, TUV

Notes

All specifications are typical at nominal input, full load, and 25°C unless otherwise noted

Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.