155W Single Output with Battery Charger
AD155 155w Power Supplies
|
Universal AC input/Full range |
|
|
Protections: Short Circuit/Over load/Over voltage |
|
|
Cooling by free air convection |
|
|
100% at full load burn-in test |
|
|
Fixed switching frequency at PFC 67KHz, PWM 134KHz |
|
Model Number |
Output Voltage |
Output Amps |
Ripple and Noise |
Over Voltage Protection |
DC Voltage Adjust (typ.) |
Efficiency |
|
13.8V/13.3V |
10.5A/0.5A |
150mVp-p max. (note 2) |
15.87~18.63V |
12~14.5V |
80% typ. |
|
|
27.6V/27.1V |
5A/0.5A |
150mVp-p max. (note 2) |
31.74~37.26V |
24~29V |
84% typ. |
|
|
54V/53.5V |
2.7A/0.2A |
240mVp-p max. (note 2) |
62.1~72.9V |
48~58V |
84% typ. |
AD155 series
|
Input Specifications
General Specifications
Environmental Specifications
|
Physical Specifications
Notes Output Specifications 1. All paramterers NOT specially mentioned are measure at 230VAC input, rated load and 25°C of ambient temperature. 2. Ripple and noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf and 47uf parallell capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. \4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. All specifications are typical at nominal input, full load, and 25°C unless otherwise noted Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. |