Order by phone: 1-800-823-8082 / +1-508-964-6300 M-F 8:30am to 5:30pm EST

A60 60w Power Supplies

60W Single Output Switching Power Supply

Universal AC input/Full range

Protections: Short Circuit/Over load/Over voltage

Cooling by free air convection

100% at full load burn-in test

Fixed switching frequency at 50KHz

Model Number

Output Voltage

Output Amps

Load Regulation

Ripple and Noise

Over Voltage Protection

DC Voltage Adjust (typ.)

Efficiency

AS60-5

5V

12A

±1.0

120mVp-p max. (note 2)

5.75~6.75V hiccup mode, recovers automatically after fault condition is removed

4.75~5.5V

0.73

AS60-12

12V

5A

±0.5

120mVp-p max. (note 2)

13.8~16.2V hiccup mode, recovers automatically after fault condition is removed

10.8~13.2V

0.76

AS60-15

15V

4A

±0.5

150mVp-p max. (note 2)

17.25~20.25V hiccup mode, recovers automatically after fault condition is removed

13.5~16.5V

0.77

AS60-24

24V

2.5A

±0.5

150mVp-p max. (note 2)

27.6~32.4V hiccup mode, recovers automatically after fault condition is removed

21.6~26.4V

0.79

AS60 series

60W Single Output Switching Power Supply

Environmental Specifications

Input Specifications

Input Voltage Range

85~264VAC 120~370VDC

Frequency Range

47~63Hz

Inrush Current

Cold Start 20A/115VAC 40A/230VAC typ.

General Specifications

Isolation

4242VDC

Isolation Input-Ground

2121VDC

Isolation Output-Ground

707VDC

Insulation Resistance

73%

Switching Frequency

UL1012, Ul1950, TUV EN60950 Approved

Operating Temperature

-10~+60°C (refer to output load derating curve)

Storage Temperature

-20~+85°C

Relative Humidity

20~90% RH non-condensing

EMI

Compliance to EN55022 (CISPR22) Class B

MTBF

316.2K hrs min. MIL-HDBK-217F (25°C)

EMS

Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A

Output Specifications

Output Voltage

5V

Output Amps

12A

Load Regulation

±1.0

Line Regulation

±0.5

Temperature Coefficient

0.3%/°C (0~50°C)

Ripple and Noise

120mVp-p max. (note 2)

Over Voltage Protection

5.75~6.75V hiccup mode, recovers automatically after fault condition is removed

Over Current Protection

105~150% rated out put power, hiccup mode, recovers automatically after fault condition is removed

DC Voltage Adjust (typ.)

4.75~5.5V

Hold Up Time

90mS/230VAC 12mS/115VAC at full load typ.

Physical Specifications

Size (mm)

159x97x38mm

Size (Inches)

6.26”x3.82”x 1.5”

Weight (g)

510g; 24pcs/13100g/0.7CUFT

Notes

1. All paramterers NOT specially mentioned are measure at 230VAC input, rated load and 25°C of ambient temperature.

2. Ripple and noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf and 47uf parallell capacitor.

3. Tolerance: includes set up tolerance, line regulation and load regulation.

4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.

All specifications are typical at nominal input, full load, and 25°C unless otherwise noted

Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.

AS-60 series