60W Single Output Switching Power Supply
A60 60w Power Supplies
|
Universal AC input/Full range |
|
|
Protections: Short Circuit/Over load/Over voltage |
|
|
Cooling by free air convection |
|
|
100% at full load burn-in test |
|
|
Fixed switching frequency at 50KHz |
|
Model Number |
Output Voltage |
Output Amps |
Load Regulation |
Ripple and Noise |
Over Voltage Protection |
DC Voltage Adjust (typ.) |
Efficiency |
|
5V |
12A |
±1.0 |
120mVp-p max. (note 2) |
5.75~6.75V hiccup mode, recovers automatically after fault condition is removed |
4.75~5.5V |
0.73 |
|
|
12V |
5A |
±0.5 |
120mVp-p max. (note 2) |
13.8~16.2V hiccup mode, recovers automatically after fault condition is removed |
10.8~13.2V |
0.76 |
|
|
15V |
4A |
±0.5 |
150mVp-p max. (note 2) |
17.25~20.25V hiccup mode, recovers automatically after fault condition is removed |
13.5~16.5V |
0.77 |
|
|
24V |
2.5A |
±0.5 |
150mVp-p max. (note 2) |
27.6~32.4V hiccup mode, recovers automatically after fault condition is removed |
21.6~26.4V |
0.79 |
AS60 series
60W Single Output Switching Power Supply
Environmental Specifications
Input Specifications
|
Input Voltage Range |
85~264VAC 120~370VDC |
|
Frequency Range |
47~63Hz |
|
Inrush Current |
Cold Start 20A/115VAC 40A/230VAC typ. |
General Specifications
|
Isolation |
4242VDC |
|
Isolation Input-Ground |
2121VDC |
|
Isolation Output-Ground |
707VDC |
|
Insulation Resistance |
73% |
|
Switching Frequency |
UL1012, Ul1950, TUV EN60950 Approved |
|
Operating Temperature |
-10~+60°C (refer to output load derating curve) |
|
Storage Temperature |
-20~+85°C |
|
Relative Humidity |
20~90% RH non-condensing |
|
EMI |
Compliance to EN55022 (CISPR22) Class B |
|
MTBF |
316.2K hrs min. MIL-HDBK-217F (25°C) |
|
EMS |
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A |
Output Specifications
|
Output Voltage |
5V |
|
Output Amps |
12A |
|
Load Regulation |
±1.0 |
|
Line Regulation |
±0.5 |
|
Temperature Coefficient |
0.3%/°C (0~50°C) |
|
Ripple and Noise |
120mVp-p max. (note 2) |
|
Over Voltage Protection |
5.75~6.75V hiccup mode, recovers automatically after fault condition is removed |
|
Over Current Protection |
105~150% rated out put power, hiccup mode, recovers automatically after fault condition is removed |
|
DC Voltage Adjust (typ.) |
4.75~5.5V |
|
Hold Up Time |
90mS/230VAC 12mS/115VAC at full load typ. |
Physical Specifications
|
Size (mm) |
159x97x38mm |
|
Size (Inches) |
6.26”x3.82”x 1.5” |
|
Weight (g) |
510g; 24pcs/13100g/0.7CUFT |
Notes
1. All paramterers NOT specially mentioned are measure at 230VAC input, rated load and 25°C of ambient temperature.
2. Ripple and noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf and 47uf parallell capacitor.
3. Tolerance: includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
All specifications are typical at nominal input, full load, and 25°C unless otherwise noted
Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.
AS-60 series