Order by phone: 1-800-823-8082 / +1-508-964-6300 M-F 8:30am to 5:30pm EST

TP100 100w 100 Watt Power Supplies

100W Triple Output with PFC Function

Universal AC input

Built-in active PFC function, PF >0.94

Protections: Short circuit / Overload / Over voltage

Fixed switching frequency at 100KHz

Free air cooling convection

Model Number

Output Voltage

Output Amps

Ripple and Noise

TP100-A

5 Volts(DC)/12 Volts(DC)/-5 Volts(DC)

10 Amps/4.0 Amps/0.6 Amps

100mVpk-pk/120mVpk-pk/100mVpk-pk (Note 1)

TP100-B

5 Volts(DC)/12 Volts(DC)/-12 Volts(DC)

10 Amps/4.0 Amps/0.6 Amps

100mVpk-pk/120mVpk-pk/100mVpk-pk (Note 1)

TP100-C

5 Volts(DC)/15 Volts(DC)/-15Volts(DC)

10 Amps/3.0 Amps/0.6 Amps

100mVpk-pk/150mVpk-pk/100mVpk-pk (Note 1)

TP100-D

5 Volts(DC)/24 Volts(DC)/12 Volts(DC)

10 Amps/2.0 Amps/0.6 Amps

100mVpk-pk/150mVpk-pk/100mVpk-pk (Note 1)

TP100 series

Input Specifications

Input Voltage Range

90-264VAC / 127-370 Volts(DC) (Note 3)

Input Reflected Ripple Current

1.5 Amps max @ 115VAC, 0.75 Amps max @ 230VAC

Frequency Range

47- 63 Hz

Inrush Current

? 40Amps @ 230VAC (cold start)

General Specifications

Isolation

4242VDC

Isolation Input-Ground

2121VDC

Isolation Output-Ground

707VDC

Insulation Resistance

77% typ.

Switching Frequency

UL60950-1 TUV EN60950-1 approved

Environmental Specifications

Operating Temperature

-10°C to +60°C (See Derate Curve)

Storage Temperature

-20°C to +85°C, 10~95% RH

Relative Humidity

20 to +90% RH non cond

MTBF

170.1KHrs min, MIL-HDBK-217F (25°C)

EMS

Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024 light industry level, criteria A

Output Specifications

Output Voltage

5 Volts(DC)/12 Volts(DC)/-5 Volts(DC)

Output Amps

10 Amps/4.0 Amps/0.6 Amps

Load Regulation

±3.0%/±6.0%/±4.0%

Line Regulation

±1.0%

Temperature Coefficient

±0.03% / °C (0-50°C)

Ripple and Noise

100mVpk-pk/120mVpk-pk/100mVpk-pk (Note 1)

Over Voltage Protection

5Volts(DC) only: 5.75~6.75Volts(DC) Shutdown o/p voltage, re-power

Over Current Protection

105~150% rated ourtput power Shutdown o/p voltage, auto recover

Over Temperature Protection

95°C ±5°C (TSW1) Shutdown o/p voltage, auto recover

DC Voltage Adjust (typ.)

5Volts(DC) only: 4.5~5.5Volts(DC)

Hold Up Time

24mS/230VAC, 24mS/115VAC

Remore Shutdown

Physical Specifications

Size (mm)

199 x 99 x 50mm

Size (Inches)

7.84” x 3.90” x 1.97”

Weight (g)

830g

Weight (oz)

27.28oz

Notes

1. Ripple and Noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47 uf parallel capacitor.

All specifications are typical at nominal input, full load, and 25°C unless otherwise noted

Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.