SD100DRL 100w Power Supplies
|
2.1 wide input range |
|
|
Protections: Short circuit/Over load/Over voltage |
|
|
1500VDC I/O isolation |
|
|
Built-in EMI filter, low ripple noise |
|
|
100% full load burn-in test |
|
|
Fixed switching frequency at 83KHz, 24V and 48V input voltage design refer to LVD, low cost, High reliability |
|
Model Number |
Input Voltage Range |
Inrush Current |
Input Current |
Leakage Current |
Output Voltage |
Output Amps |
Load Regulation |
Line Regulation |
Ripple and Noise |
Over Voltage Protection |
|
19~ 36VDC |
4.8A/24V |
5V |
20A |
+/- 0.5% |
+/- 0.5% |
100mVp-p max. (Note 2) |
5.75~6.75V/10% load, Protection type: Hiccup mode, recovers automatically after fault condition is removed |
|||
|
36~ 72VDC |
4.8A/24V |
5V |
20A |
+/- 0.5% |
+/- 0.5% |
100mVp-p max. (Note 2) |
5.75~6.75V/10% load, Protection type: Hiccup mode, recovers automatically after fault condition is removed |
|||
|
72~ 144VDC or 85~ 132VAC |
18A/ 96VDC |
4.8A/24V |
<0.75mA/ 240VAC |
5V |
20A |
+/- 0.5% |
+/- 0.5% |
100mVp-p max. (Note 2) |
5.75~6.75V/10% load, Protection type: Hiccup mode, recovers automatically after fault condition is removed |
|
|
19~ 36VDC |
2.4A/48V |
12V |
8.5A |
+/- 0.3% |
+/- 0.3% |
120mVp-p max. (Note 2) |
16.8~20V/10% load, Protection type: Hiccup mode, recovers automatically after fault condition is removed |
|||
|
36~ 72VDC |
2.4A/48V |
12V |
8.5A |
+/- 0.3% |
+/- 0.3% |
120mVp-p max. (Note 2) |
16.8~20V/10% load, Protection type: Hiccup mode, recovers automatically after fault condition is removed |
|||
|
72~ 144VDC or 85~ 132VAC |
18A/ 96VDC |
2.4A/48V |
<0.75mA/ 240VAC |
12V |
8.5A |
+/- 0.3% |
+/- 0.3% |
120mVp-p max. (Note 2) |
16.8~20V/10% load, Protection type: Hiccup mode, recovers automatically after fault condition is removed |
|
|
19~ 36VDC |
1.2A/96V |
24V |
4.2A |
+/- 0.2% |
+/- 0.2% |
150mVp-p max. (Note 2) |
31.5~37.5V/10% load, Protection type: Hiccup mode, recovers automatically after fault condition is removed |
|||
|
36~ 72VDC |
1.2A/96V |
24V |
4.2A |
+/- 0.2% |
+/- 0.2% |
150mVp-p max. (Note 2) |
31.5~37.5V/10% load, Protection type: Hiccup mode, recovers automatically after fault condition is removed |
|||
|
72~ 144VDC or 85~ 132VAC |
18A/ 96VDC |
1.2A/96V |
<0.75mA/ 240VAC |
24V |
4.2A |
+/- 0.2% |
+/- 0.2% |
150mVp-p max. (Note 2) |
31.5~37.5V/10% load, Protection type: Hiccup mode, recovers automatically after fault condition is removed |
SD100/DRL series
|
Model Number |
Voltage Tolerance |
DC Voltage Adjust |
Minimum Load Requirement |
Set Up, Rise Time |
Hold Up Time |
MTBF |
Efficiency |
|
SD100B-5/DRL |
+/- 2.0% (Note 3) |
4.5~5.5VDC |
0~20A |
356.7K hrs min. MIL-HDBK-217F (25°C) |
74% typ. |
||
|
SD100C-5/DRL |
+/- 2.0% (Note 3) |
4.5~5.5VDC |
0~20A |
355.5K hrs min. MIL-HDBK-217F (25°C) |
75% typ. |
||
|
SD100D-5/DRL |
+/- 2.0% (Note 3) |
4.5~5.5VDC |
0~20A |
2s, 50ms at full load |
24ms at full load |
341.9K hrs min. MIL-HDBK-217F (25°C) |
76% typ. |
|
SD100B-12/DRL |
+/- 1.0% (Note 3) |
11~16VDC |
0~8.3A |
356.7K hrs min. MIL-HDBK-217F (25°C) |
75% typ. |
||
|
SD100C-12/DRL |
+/- 1.0% (Note 3) |
11~16VDC |
0~8.3A |
355.5K hrs min. MIL-HDBK-217F (25°C) |
77% typ. |
||
|
SD100D-12/DRL |
+/- 1.0% (Note 3) |
11~16VDC |
0~8.3A |
2s, 50ms at full load |
24ms at full load |
341.9K hrs min. MIL-HDBK-217F (25°C) |
80% typ. |
|
SD100B-24/DRL |
+/- 1.0% (Note 3) |
23~30VDC |
0~4.2A |
356.7K hrs min. MIL-HDBK-217F (25°C) |
78% typ. |
||
|
SD100C-24/DRL |
+/- 1.0% (Note 3) |
23~30VDC |
0~4.2A |
355.5K hrs min. MIL-HDBK-217F (25°C) |
81% typ. |
||
|
SD100D-24/DRL |
+/- 1.0% (Note 3) |
23~30VDC |
0~4.2A |
2s, 50ms at full load |
24ms at full load |
341.9K hrs min. MIL-HDBK-217F (25°C) |
83% typ. |
|
General Specifications
Environmental Specifications Input Specifications
|
Output Specifications Physical Specifications
Notes
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 °C of ambient temperature. 2. Ripple and noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equpiment must be re-confirmed that it still meets EMC directives. All specifications are typical at nominal input, full load, and 25°C unless otherwise noted Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. |