Order by phone: 1-800-823-8082 / +1-508-964-6300 M-F 8:30am to 5:30pm EST

SD100DRL 100w Power Supplies

100W Single Output DC-DC Converter

2.1 wide input range

Protections: Short circuit/Over load/Over voltage

1500VDC I/O isolation

Built-in EMI filter, low ripple noise

100% full load burn-in test

Fixed switching frequency at 83KHz, 24V and 48V input voltage design refer to LVD, low cost, High reliability

Model Number

Input Voltage Range

Inrush Current

Input Current

Leakage Current

Output Voltage

Output Amps

Load Regulation

Line Regulation

Ripple and Noise

Over Voltage Protection

SD100B-5/DRL

19~ 36VDC

4.8A/24V

5V

20A

+/- 0.5%

+/- 0.5%

100mVp-p max. (Note 2)

5.75~6.75V/10% load, Protection type: Hiccup mode, recovers automatically after fault condition is removed

SD100C-5/DRL

36~ 72VDC

4.8A/24V

5V

20A

+/- 0.5%

+/- 0.5%

100mVp-p max. (Note 2)

5.75~6.75V/10% load, Protection type: Hiccup mode, recovers automatically after fault condition is removed

SD100D-5/DRL

72~ 144VDC or 85~ 132VAC

18A/ 96VDC

4.8A/24V

<0.75mA/ 240VAC

5V

20A

+/- 0.5%

+/- 0.5%

100mVp-p max. (Note 2)

5.75~6.75V/10% load, Protection type: Hiccup mode, recovers automatically after fault condition is removed

SD100B-12/DRL

19~ 36VDC

2.4A/48V

12V

8.5A

+/- 0.3%

+/- 0.3%

120mVp-p max. (Note 2)

16.8~20V/10% load, Protection type: Hiccup mode, recovers automatically after fault condition is removed

SD100C-12/DRL

36~ 72VDC

2.4A/48V

12V

8.5A

+/- 0.3%

+/- 0.3%

120mVp-p max. (Note 2)

16.8~20V/10% load, Protection type: Hiccup mode, recovers automatically after fault condition is removed

SD100D-12/DRL

72~ 144VDC or 85~ 132VAC

18A/ 96VDC

2.4A/48V

<0.75mA/ 240VAC

12V

8.5A

+/- 0.3%

+/- 0.3%

120mVp-p max. (Note 2)

16.8~20V/10% load, Protection type: Hiccup mode, recovers automatically after fault condition is removed

SD100B-24/DRL

19~ 36VDC

1.2A/96V

24V

4.2A

+/- 0.2%

+/- 0.2%

150mVp-p max. (Note 2)

31.5~37.5V/10% load, Protection type: Hiccup mode, recovers automatically after fault condition is removed

SD100C-24/DRL

36~ 72VDC

1.2A/96V

24V

4.2A

+/- 0.2%

+/- 0.2%

150mVp-p max. (Note 2)

31.5~37.5V/10% load, Protection type: Hiccup mode, recovers automatically after fault condition is removed

SD100D-24/DRL

72~ 144VDC or 85~ 132VAC

18A/ 96VDC

1.2A/96V

<0.75mA/ 240VAC

24V

4.2A

+/- 0.2%

+/- 0.2%

150mVp-p max. (Note 2)

31.5~37.5V/10% load, Protection type: Hiccup mode, recovers automatically after fault condition is removed

SD100/DRL series

Model Number

Voltage Tolerance

DC Voltage Adjust

Minimum Load Requirement

Set Up, Rise Time

Hold Up Time

MTBF

Efficiency

SD100B-5/DRL

+/- 2.0% (Note 3)

4.5~5.5VDC

0~20A

356.7K hrs min. MIL-HDBK-217F (25°C)

74% typ.

SD100C-5/DRL

+/- 2.0% (Note 3)

4.5~5.5VDC

0~20A

355.5K hrs min. MIL-HDBK-217F (25°C)

75% typ.

SD100D-5/DRL

+/- 2.0% (Note 3)

4.5~5.5VDC

0~20A

2s, 50ms at full load

24ms at full load

341.9K hrs min. MIL-HDBK-217F (25°C)

76% typ.

SD100B-12/DRL

+/- 1.0% (Note 3)

11~16VDC

0~8.3A

356.7K hrs min. MIL-HDBK-217F (25°C)

75% typ.

SD100C-12/DRL

+/- 1.0% (Note 3)

11~16VDC

0~8.3A

355.5K hrs min. MIL-HDBK-217F (25°C)

77% typ.

SD100D-12/DRL

+/- 1.0% (Note 3)

11~16VDC

0~8.3A

2s, 50ms at full load

24ms at full load

341.9K hrs min. MIL-HDBK-217F (25°C)

80% typ.

SD100B-24/DRL

+/- 1.0% (Note 3)

23~30VDC

0~4.2A

356.7K hrs min. MIL-HDBK-217F (25°C)

78% typ.

SD100C-24/DRL

+/- 1.0% (Note 3)

23~30VDC

0~4.2A

355.5K hrs min. MIL-HDBK-217F (25°C)

81% typ.

SD100D-24/DRL

+/- 1.0% (Note 3)

23~30VDC

0~4.2A

2s, 50ms at full load

24ms at full load

341.9K hrs min. MIL-HDBK-217F (25°C)

83% typ.

General Specifications

Isolation

1.5KVAC (Note 4)

Isolation Input-Ground

1.5KVAC (Note 4)

Isolation Output-Ground

0.5KVAC (Note 4)

Insulation Resistance

100M Ohms/500VDC (Note 4)

Efficiency

74% typ.

Safety Approvals

24V an 48V input design refer to LVD

Environmental Specifications

Input Specifications

Operating Temperature

-10°C to +60°C (Refer to outlput load derating curve)

Storage Temperature

-20°C to +85°C

Working Humidity

20 to +90% RH non cond

Storage Humidity

10 ~ 95% RH

EMI

Compliance to EN 55022 (CISPR22) Class B (Note 4)

MTBF

356.7K hrs min. MIL-HDBK-217F (25°C)

Vibration

10 ~ 500Hz. 2G 10- min./1 cycle, 60min. Each along X, Y, Z axes

EMS

Compliance to EN61000-4-2,3,4,5,6,8; ENV50204, heavy industry level, criteria A (Note 4)

Input Voltage Range

19~36VDC

Input Current

4.8A/24V

Output Specifications

Physical Specifications

Size (mm)

199x98x38

Weight (g)

0.65Kg; 20pcs/13.8Kg/0.8CUFT

Notes

Output Voltage

5V

Output Amps

20A

Load Regulation

± 0.5%

Line Regulation

± 0.5%

Temperature Coefficient

±0.03%/°C (0~50°C)

Ripple and Noise

100mVp-p max. (Note 2)

Over Voltage Protection

5.75~6.75V/10% load, Protection type: Hiccup mode, recovers automatically after fault condition is removed

Over Current Protection

105 ~ 135% rated output power, Protection type: fold back current limiting, recovers automatically after fault condition is removed

Voltage Tolerance

± 2.0% (Note 3)

DC Voltage Adjust

4.5~5.5VDC

Minimum Load Requirement

0~20A

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 °C of ambient temperature.

2. Ripple and noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance: includes set up tolerance, line regulation and load regulation.

4. The power supply is considered a component which will be installed into a final equipment. The final equpiment must be re-confirmed that it still meets EMC directives.

All specifications are typical at nominal input, full load, and 25°C unless otherwise noted

Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.