RS100 100w Switch Mode Power Supplies
|
Universal AC input |
|
|
Protections:Short circuit/Over load/Over voltage |
|
|
Cooling by free air convection |
|
|
LED indicator for power on |
|
|
All using 105°C long life electrolytic capacitors |
|
|
High efficiency, long life and high reliability |
|
Model Number |
Output Voltage |
Output Amps |
Load Regulation |
Ripple and Noise |
Over Voltage Protection |
DC Voltage Adjust (typ.) |
Efficiency |
|
3.3 Volts(DC) |
20 Amps |
±2.0% (Note 4) |
80mV pk-pk (Note 1) |
3.8 ~ 4.45Volt(DC) Hiccup mode, auto recov |
3.2~3.5Volt(DC) |
0.74 |
|
|
5 Volts(DC) |
16 Amps |
±1.0% (Note 4) |
80mV pk-pk (Note 1) |
5.75 ~ 6.75Volt(DC) Hiccup mode, auto recov |
4.75~5.5Volt(DC) |
0.77 |
|
|
12 Volts(DC) |
8.5 Amps |
±0.5% (Note 4) |
120mV pk-pk (Note 1) |
13.8 ~ 16.2Volt(DC) Hiccup mode, auto recov |
11.4~13.2Volt(DC) |
0.81 |
|
|
15 Volts(DC) |
7.0 Amps |
±0.5% (Note 4) |
120mV pk-pk (Note 1) |
17.25 ~ 20.25Volt(DC) Hiccup mode, auto recov |
14.25~16.5Volt(DC) |
0.82 |
|
|
24 Volts(DC) |
4.5 Amps |
±0.5% (Note 4) |
120mV pk-pk (Note 1) |
27.6~ 32.4Volt(DC) Hiccup mode, auto recov |
22.8~26.4Volt(DC) |
0.84 |
|
|
48 Volts(DC) |
2.3 Amps |
±0.5% (Note 4) |
200mV pk-pk (Note 1) |
55.2~ 64.8Volt(DC) Hiccup mode, auto recov |
45.6~52.8Volt(DC) |
0.84 |
RS100 series
|
Input Specifications
General Specifications
Environmental Specifications
|
Output Specifications
Notes Physical Specifications 1. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. All specifications are typical at nominal input, full load, and 25°C unless otherwise noted Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. |