RQ85 85w Switch Mode Power Supplies
|
Universal AC input |
|
|
LED indicator for power on |
|
|
Protections: Short circuit / Overload / Over voltage |
|
|
All using 105°C long life electrolytic capacitors |
|
|
Cooling by free air convection |
|
|
High efficiency, long life and high reliability |
|
Model Number |
Output Voltage |
Output Amps |
Load Regulation |
Ripple and Noise |
Efficiency |
|
5 Volts(DC)/12 Volts(DC)/-5 Volts(DC)/-12 Volts(DC) |
7.0 Amps/3.1 Amps/0.5 Amps/0.5 Amps |
±1.0%±3.0%/±6.0%/±2.0% (Note 4) |
80mVpk-pk/120mVpk-pk/100mVpk-pk/80mVpk-pk |
0.76 |
|
|
5 Volts(DC)/15 Volts(DC)/-5 Volts(DC)/-15 Volts(DC) |
7.0 Amps/2.5 Amps/0.5 Amps/0.5 Amps |
±1.0%±3.0%/±6.0%/±2.0% (Note 4) |
80mVpk-pk/120mVpk-pk/100mVpk-pk/80mVpk-pk |
0.77 |
|
|
5 Volts(DC)/12 Volts(DC)/24 Volts(DC)/-12 Volts(DC) |
6.0 Amps/2.0 Amps/1.0 Amps/0.5 Amps |
±1.0%±3.0%/±5.0%/±2.0% (Note 4) |
80mVpk-pk/120mVpk-pk/150mVpk-pk/80mVpk-pk |
0.78 |
RQ85 series
|
Input Specifications
General Specifications
Environmental Specifications
|
Output Specifications
Physical Specifications
Notes 1. Ripple and Noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47 uf parallel capacitor. All specifications are typical at nominal input, full load, and 25°C unless otherwise noted Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. |