Order by phone: 1-800-823-8082 / +1-508-964-6300 M-F 8:30am to 5:30pm EST

RQ50 50w Switch Mode Power Supplies

50W Quad Output Switching Power Supply

Model Number

Output Voltage

Output Amps

Load Regulation

Line Regulation

Ripple and Noise

Efficiency

RQ50-B

5 Volts(DC)/12 Volts(DC)/-5 Volts(DC)/-12 Volts(DC)

5.0 Amps/1.0 Amps/0.5 Amps/0.5 Amps

±0.5%/±3.0%/±1.0%/±1.0% (Note 4)

±0.5%/±1.5%/±0.5%/±0.5% (Note 3)

80mVpk-pk/120mVpk-pk/100mVpk-pk/80mVpk-pk (Note 1)

0.74

RQ50-C

5 Volts(DC)/15 Volts(DC)/-5 Volts(DC)/-15 Volts(DC)

5.0 Amps/1.0 Amps/0.5 Amps/0.5 Amps

±0.5%/±3.0%/±1.0%/±1.0% (Note 4)

±0.5%/±1.5%/±0.5%/±0.5% (Note 3)

80mVpk-pk/120mVpk-pk/100mVpk-pk/80mVpk-pk (Note 1)

0.75

RQ50-D

5 Volts(DC)/12 Volts(DC)/24 Volts(DC)/-12 Volts(DC)

3.0 Amps/0.9 Amps/0.9 Amps/0.5 Amps

±0.5%/±3.0%/±3.0%/±1.0% (Note 4)

±0.5%/±1.5%/±2.0%/±0.5% (Note 3)

80mVpk-pk/120mVpk-pk/180mVpk-pk/80mVpk-pk (Note 1)

0.79

Universal AC input

LED indicator for power on

Protections: Short circuit / Overload / Over voltage

All using 105°C long life electrolytic capacitors

Cooling by free air convection

High efficiency, long life and high reliability

RQ50 series

Input Specifications

Input Voltage Range

90-264VAC / 125-373 Volts(DC)

Input Reflected Ripple Current

1.3Amps max @115VAC, 0.8Amps max @230VAC

Frequency Range

47~63Hz

Inrush Current

36 Amps @ 230VAC (cold start)

General Specifications

Isolation

4242VDC

Isolation Input-Ground

2121VDC

Isolation Output-Ground

707VDC

Insulation Resistance

74%

Switching Frequency

UL60950-1 TUV EN60950-1 Approved

Environmental Specifications

Operating Temperature

-25°C to +70°C (See Derate Curve)

Storage Temperature

-40°C to +85°C, 10~95% RH

Relative Humidity

20 to +90% RH non cond

MTBF

162.9K Hrs min, MIL-HDBK-217F (25°C)

EMS

Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61000-6-2(EN50082-2) heavy industry level, criteria A

Output Specifications

Output Voltage

5 Volts(DC)/12 Volts(DC)/-5 Volts(DC)/-12 Volts(DC)

Output Amps

5.0 Amps/1.0 Amps/0.5 Amps/0.5 Amps

Load Regulation

±0.5%/±3.0%/±1.0%/±1.0% (Note 4)

Line Regulation

±0.5%/±1.5%/±0.5%/±0.5% (Note 3)

Temperature Coefficient

±0.03% / °C (0-50°C) on +5Volts output

Ripple and Noise

80mVpk-pk/120mVpk-pk/100mVpk-pk/80mVpk-pk (Note 1)

Over Voltage Protection

5Volts(DC) only: 5.75~6.75Volts(DC) Hiccup mode, auto recover

Over Current Protection

110~150% rated output power Hiccup mode, auto recover

DC Voltage Adjust (typ.)

5Volts(DC)only: 4.75~5.5Volts(DC)

Hold Up Time

60mS/230VAC, 10mS/115VAC

Physical Specifications

1. Ripple and Noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47 uf parallel capacitor.

All specifications are typical at nominal input, full load, and 25°C unless otherwise noted

Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.

Size (mm)

99 x 97 x 36mm

Size (Inches)

3.90” x 3.82” x 1.42”

Weight (g)

410g

Weight (oz)

14.46oz

Notes