125W Dual Output Switching Power Supply
RD125 125w Switch Mode Power Supplies
|
Universal AC input |
|
|
Protections:Short circuit/Over load/Over voltage |
|
|
Cooling by free air convection |
|
|
LED indicator for power on |
|
|
All using 105°C long life electrolytic capacitors |
|
|
High efficiency, long life and high reliability |
|
Model Number |
Output Voltage |
Output Amps |
Load Regulation |
Line Regulation |
Temperature Coefficient |
Ripple and Noise |
Over Voltage Protection |
DC Voltage Adjust (typ.) |
|
5 Volts(DC) /12 Volts(DC) |
7.7 Amps/ 7.7 Amps |
±3.0%/±4.0% |
±1.0%/±2.0% |
0.03% / °C (0-50°C) on +5V output |
80mV pk-pk/120mV pk-pk (Note 1) |
5Volts only: : 5.75 ~ 6.75Volts(DC) Hiccup mode, auto recover |
5Volts only: 4.75 ~ 5.5Volts(DC) |
|
|
5 Volts(DC) /24 Volts(DC) |
4.6 Amps/ 4.6 Amps |
±3.0%/±4.0% |
±1.0%/±2.0% |
0.03% / °C (0-50°C) on +5V output |
80mV pk-pk/120mV pk-pk (Note 1) |
5Volts only: : 5.75 ~ 6.75Volts(DC) Hiccup mode, auto recover |
5Volts only: 4.75 ~ 5.5Volts(DC) |
|
|
12 Volts(DC)/ 24 Volts(DC) |
3.7Amps/ 3.7Amps |
±1.0%/±5.0% |
±0.5%/±1.0% |
0.03% / °C (0-50°C) on +12V output |
120mV pk-pk/200mV pk-pk (Note 1) |
12Volts only: : 13.8 ~ 16.2Volts(DC) Hiccup mode, auto recover |
12Volts only: 11.4~ 13.2Volts(DC) |
|
|
12 Volts(DC)/ 48 Volts(DC) |
2.3 Amps/ 2.3 Amps |
±1.0%/±5.0% |
±0.5%/±1.0% |
0.03% / °C (0-50°C) on +12V output |
120mV pk-pk/240mV pk-pk (Note 1) |
12Volts only: : 13.8 ~ 16.2Volts(DC) Hiccup mode, auto recover |
12Volts only: 11.4~ 13.2Volts(DC) |
|
|
24 Volts(DC)/ 48 Volts(DC) |
2.0 Amps/ 2.0 Amps |
±1.0%/±3.0% |
±0.5%/±1.0% |
0.03% / °C (0-50°C) on +24V output |
200mV pk-pk/240mV pk-pk (Note 1) |
24Volts only: : 27.6 ~ 32.4Volts(DC) Hiccup mode, auto recover |
24Volts only: 22.8~ 26.4Volts(DC) |
|
|
24 Volts(DC)/ 12 Volts(DC) |
3.7Amps/ 3.7Amps |
±1.0%/±5.0% |
±0.5%/±1.0% |
0.03% / °C (0-50°C) on +24V output |
200mV pk-pk/120mV pk-pk (Note 1) |
24Volts only: : 27.6 ~ 32.4Volts(DC) Hiccup mode, auto recover |
24Volts only: 22.8~ 26.4Volts(DC) |
|
|
48 Volts(DC)/ 12 Volts(DC) |
2.3 Amps/ 2.3 Amps |
±1.0%/±5.0% |
±0.5%/±1.0% |
0.03% / °C (0-50°C) on +48V output |
240mV pk-pk/120mV pk-pk (Note 1) |
48Volts only: : 55.2 ~ 64.8Volts(DC) Hiccup mode, auto recover |
40Volts only: 45.6~ 52.6Volts(DC) |
|
|
48 Volts(DC)/ 24 Volts(DC) |
2.0Amps/ 2.0Amps |
±1.0%/±5.0% |
±0.5%/±1.0% |
0.03% / °C (0-50°C) on +48V output |
240mV pk-pk/240mV pk-pk (Note 1) |
48Volts only: : 55.2 ~ 64.8Volts(DC) Hiccup mode, auto recover |
40Volts only: 45.6~ 52.6Volts(DC) |
RD125 series
|
Input Specifications
General Specifications
Environmental Specifications
|
Output Specifications
Notes 1. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. All specifications are typical at nominal input, full load, and 25°C unless otherwise noted Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. Physical Specifications
|