Order by phone: 1-800-823-8082 / +1-508-964-6300 M-F 8:30am to 5:30pm EST

PS65 65w Power Supplies

Universal AC input

Protections:Short circuit/Over load/Over voltage

Low leakage current <0.5mA

Cooling by free air convention

Fixed switching frequency at 65KHz

Model Number

Output Voltage

Output Amps

Minimum Load Requirement

Load Regulation

Ripple and Noise

Voltage Tolerance

Over Voltage Protection

Over Current Protection

DC Voltage Adjust (typ.)

Efficiency

PS65-3.3

3.3 Volts(DC)

12 Amps

0~ 15.2Amps

±3.0%

80mVpk-pk (note 1)

3.0% (note 2)

3.8 ~ 4.46Volt(DC) Hiccup mode, auto recover

36~55W rated output power, Hiccup mode, auto recover

3.14~ 3.63Volt(DC)

69%

PS65-5

5 Volts(DC)

12 Amps

0~ 13.8Amps

±3.0%

100mVpk-pk (note 1)

3.0% (note 2)

5.75 ~ 6.75Volt(DC) Hiccup mode, auto recover

70~105W rated output power, Hiccup mode, auto recover

4.75~ 5.5Volt(DC)

76%

PS65-7.5

7.5 Volts(DC)

8.0 Amps

0~ 9.6Amps

±3.0%

100mVpk-pk (note 1)

3.0% (note 2)

8.63 ~ 10.1Volt(DC) Hiccup mode, auto recover

73~105W rated output power, Hiccup mode, auto recover

7.13~ 8.25Volt(DC)

79%

PS65-12

12 Volts(DC)

5.2 Amps

0~ 6.0Amps

±2.0%

100mVpk-pk (note 1)

2.0% (note 2)

13.8 ~ 16.2Volt(DC) Hiccup mode, auto recover

73~105W rated output power, Hiccup mode, auto recover

11.4~ 13.2Volt(DC)

79%

PS65-13.5

13.5 Volts(DC)

4.7 Amps

0~ 5.4Amps

±2.0%

100mVpk-pk (note 1)

2.0% (note 2)

15.5 ~ 18.2Volt(DC) Hiccup mode, auto recover

73~105W rated output power, Hiccup mode, auto recover

12.8~ 14.9Volt(DC)

79%

PS65-15

15 Volts(DC)

4.2 Amps

0~ 4.8Amps

±2.0%

100mVpk-pk (note 1)

2.0% (note 2)

17.25 ~ 20.25Volt(DC) Hiccup mode, auto recover

73~105W rated output power, Hiccup mode, auto recover

14.25~ 16.5Volt(DC)

79%

PS65-24

24 Volts(DC)

2.7 Amps

0~ 3.0Amps

±2.0%

100mVpk-pk (note 1)

2.0% (note 2)

27.6 ~ 32.4Volt(DC) Hiccup mode, auto recover

73~105W rated output power, Hiccup mode, auto recover

22.8~ 26.4Volt(DC)

80%

PS65-27

27 Volts(DC)

2.4 Amps

0~ 2.7Amps

±2.0%

100mVpk-pk (note 1)

2.0% (note 2)

31~ 36.45Volt(DC) Hiccup mode, auto recover

73~105W rated output power, Hiccup mode, auto recover

25.65~ 29.7Volt(DC)

80%

PS65-48

48 Volts(DC)

1.35 Amps

0~ 1.5Amps

±2.0%

100mVpk-pk (note 1)

2.0% (note 2)

55.2~ 64.8Volt(DC) Hiccup mode, auto recover

73~105W rated output power, Hiccup mode, auto recover

45.6~ 52.8Volt(DC)

80%

PS65 series

Input Specifications

Input Voltage Range

90 ~ 264VAC 127~370 Volts(DC)

Frequency Range

47-440Hz

Inrush Current

20Amps/115VAC; 40Amps/230VAC (cold start)

Input Current

1.2 Amps@115VAC, 0.72 Amps@230VAC

Leakage Current

< 0.5mAmps / 240VAC

Harmonic Input Current

Compliance to EN61000-3-2,-3

Environmental Specifications

Operating Temperature

-10°C to +60°C (See Derate Curve)

Storage Temperature

-20°C to +85°C, 10~95% RH

Relative Humidity

20 to +90% RH non cond

EMI

Compliance to EN55022 (CISPR22) Class B

MTBF

300.7KHrs min,MIL-HDBK-217F(25°C)

Vibration

10~500Hz, 2G10min./1cycle, period for 60min. each along X, Y, Z axes

Cooling

free air convection

EMS

Compliance to EN61000-4-2,3,4,5,6,8,11 ENV50204, ENV55024 light Industry Level, Criteria A

General Specifications

Isolation

3000VAC

Isolation Input-Ground

1500VAC

Isolation Output-Ground

500VAC

Insulation Resistance

≥ 100MΩ / 500Volts(DC)

Efficiency

69%

Safety Approvals

UL60950, TUV EN60950-1 Approved

Output Specifications

Output Voltage

3.3 Volts(DC)

Output Amps

12 Amps

Minimum Load Requirement

0~15.2Amps

Load Regulation

±3.0%

Line Regulation

±1.0%

Temperature Coefficient

±0.04% / °C (0-50°C)

Ripple and Noise

80mVpk-pk (note 1)

Voltage Tolerance

3.0% (note 2)

Over Voltage Protection

3.8 ~ 4.46Volt(DC) Hiccup mode, auto recover

Over Current Protection

36~55W rated output power, Hiccup mode, auto recover

Rise Time

800mS, 20mS

Hold Up Time

60mS

DC Voltage Adjust (typ.)

3.14~3.63Volt(DC)

Physical Specifications

Size (mm)

127 x 76.2 x 28 mm

Size (Inches)

5”x 3”x 1.10”

Weight (g)

210g

Weight (oz)

7.41oz

Notes

1. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

2. Tolerance : includes set up tolerance, line regulation and load regulation.

3. Mounting holes M1 and M2 should be grounded for EMI purposes.

All specifications are typical at nominal input, full load, and 25°C unless otherwise noted

Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.