PMMK150D 150w Power Supplies

150 Watt Enclosed with DIN Rail mount and PFC

150 Watts output power

Universal 90-264VAC Input

5VDC to 48VDC Outputs

3000VAC input to Output Isolation

Active power factor correction

Model Number

Output Voltage

Output Amps

Load Regulation

Line Regulation

Ripple and Noise

PMMK150S-5D

5 VDC (Note 6)

30

± 0.5%, 10%-FL typ. (Note 7)

±0.5% (Note 8)

100mV pk-pk (Notes 1, 3, 10)

PMMK150S-12D

12 VDC (Note 6)

12.5

± 0.5%, 10%-FL typ. (Note 7)

±0.5% (Note 8)

100mV pk-pk (Notes 1, 3, 10)

PMMK150S-15D

15 VDC (Note 6)

10

± 0.5%, 10%-FL typ. (Note 7)

±0.5% (Note 8)

100mV pk-pk (Notes 1, 3, 10)

PMMK150S-24D

24 VDC (Note 6)

6.3

± 0.5%, 10%-FL typ. (Note 7)

±0.5% (Note 8)

100mV pk-pk (Notes 1, 3, 10)

PMMK150S-48D

48 VDC (Note 6)

3.2

± 0.5%, 10%-FL typ. (Note 7)

±0.5% (Note 8)

100mV pk-pk (Notes 1, 3, 10)

PMMK150D-AD

5/12 VDC (Note 6)

15/7

±3/5%, 10%-FL typ. (Note 7)

±0.5/1% (Note 8)

50/100mV pk-pk (Notes 1, 3, 10)

PMMK150D-BD

5/24 VDC (Note 6)

15/3.5

±3/5%, 10%-FL typ. (Note 7)

±0.5/2% (Note 8)

50/200mV pk-pk (Notes 1, 3, 10)

PMMK150D-CD

12/24 VDC (Note 6)

7/3.5

±3/5%, 10%-FL typ. (Note 7)

±1/2% (Note 8)

100/200mV pk-pk (Notes 1, 3, 10)

PMMK150D-DD

12/48 VDC (Note 6)

7/1.5

±3/5%, 10%-FL typ. (Note 7)

±1/4% (Note 8)

100/400mV pk-pk (Notes 1, 3, 10)

PMMK150D series

General Specifications

Isolation

5656VDC (Note 4)

Isolation Input-Ground

2000VAC (Note 4)

Isolation Output-Ground

500VAC (Note 4)

Switching Frequency

67KHz (fixed, typical)

Efficiency

75% min.

Safety Approvals

UL,TUV, CB, CE

Environmental Specifications

Operating Temperature

-10 to +70°C (See Derate Curve)

Storage Temperature

-25 to +85°C

Working Humidity

0% to +95%, non-cond *

MTBF

270,000 Hrs Mil Std 217, 25°C

EMS

EN55011 Class B

Input Specifications

Input Voltage Range

90-264 VAC

Frequency Range

47 ~ 63Hz

Inrush Current

30A @ 115VAC 60A @ 230VAC

Power Factor Correction

0.96 to 0.98

Physical Specifications

Size (Inches)

3.2” x 5.5” x 1.6”

Weight (g)

635g

Weight (oz)

1.4 lb,

Construction

Enclosed DIN Rail

Output Specifications

Notes

1. All measurements should be made directly at the terminals of the power supply.

2. All specifications typical @ 25°C, unless otherwise noted, at nominal line and load.

3. Ripple and noise dependent upon output voltage as specified per particular model.

4. Isolation for up to 1 minute duration.

5. Specified for free air convection cooling.

6. Minimum load is not required for proper operation.

7. Load Regulation is measured by change ±40% of measured output load from 60% full load, with the other output set to 60% full load.

8. Line Regulation measured from 90-264VAC. 100VAC minimum required for full load start.

9. Preset Accuracy measured at nominal load, 120VAC input.

10. O/P Noise measured directly at the pins/terminals at nominal load, 0.1uF bypass and 47uF electrolytic, pk-pk @ 20MHz bandwidth.

All specifications are typical at nominal input, full load, and 25°C unless otherwise noted

Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.

Output Voltage

5 VDC (Note 6)

Output Amps

30

Load Regulation

± 0.5%, 10%-FL typ. (Note 7)

Line Regulation

±0.5% (Note 8)

Temperature Coefficient

±0.05%/°C

Ripple and Noise

100mV pk-pk (Notes 1, 3, 10)

Over Voltage Protection

Latching, Auto Recover after fault condition is removed

Short Circuit Protection

Latching, Auto Recover after fault condition is removed

DC Voltage Adjust

±6%, typ

Preset Accuracy

±1%, typ (Note 9)

Hold Up Time

20mS, typ (Nom I/P, FL)