PMK150U 150w Power Supplies

150 Watts Output Power

Single and Dual Outputs

Universal 90-264VAC Input

5VDC to 48VDC Outputs

3000VAC Input to Output Isolation

Active Power Factor Correction

Model Number

Output Voltage

Output Amps

Load Regulation

Line Regulation

Ripple and Noise

PMK150S-5U

5 VDC

30 Amps

± 0.5%, typ (10%-FL, Note 7)

±0.5% (note 8)

100mV pk-pk (Notes 1,3, 10)

PMK150S-12U

12 VDC

12.5 Amps

± 0.5%, typ (10%-FL, Note 7)

±0.5% (note 8)

100mV pk-pk (Notes 1,3, 10)

PMK150S-15U

15 VDC

10 Amps

± 0.5%, typ (10%-FL, Note 7)

±0.5% (note 8)

100mV pk-pk (Notes 1,3, 10)

PMK150S-24U

24 VDC

6.3 Amps

± 0.5%, typ (10%-FL, Note 7)

±0.5% (note 8)

100mV pk-pk (Notes 1,3, 10)

PMK150S-48U

48 VDC

3.2 Amps

± 0.5%, typ (10%-FL, Note 7)

±0.5% (note 8)

100mV pk-pk (Notes 1,3, 10)

PMK150D-AU

5/12 VDC

15/7 Amps

±3/5%, typ (10%-FL, Note 7)

±0.5/1% (note 8)

50/100mV pk-pk (Notes 1,3, 10)

PMK150D-BU

5/24 VDC

15/3.5 Amps

±3/5%, typ (10%-FL, Note 7)

±0.5/2% (note 8)

50/200mV pk-pk (Notes 1,3, 10)

PMK150D-CU

12/24 VDC

7/3.5 Amps

±3/5%, typ (10%-FL, Note 7)

±1/2% (note 8)

100/200mV pk-pk (Notes 1,3, 10)

PMK150D-DU

12/48 VDC

7/1.5 Amps

±3/5%, typ (10%-FL, Note 7)

±1/4% (note 8)

100/400mV pk-pk (Notes 1,3, 10)

PMK150U series

Input Specifications

Input Voltage Range

90-264 VAC

Frequency Range

47-63 Hz

Inrush Current

30A @ 115VAC, 60A @ 230VAC *

Power Factor Correction

0.96 to 0.98

Environmental Specifications

Operating Temperature

-10 to +70°C (See Derate Curve)

EMC

EN55011 Class B

Storage Temperature

-25 to +85°C *

MTBF

270,000 Hrs, Mil Std 217, 25°C

General Specifications

Isolation

3000VAC (note 4)

Isolation Input-Ground

2000VAC (note 4)

Isolation Output-Ground

500VAC (note 4)

Efficiency

75%, min.

Switching Frequency

67Khz, (fixed, typical)

Safety Approvals

UL,TUV, CB, CE

Output Specifications

Output Voltage

5 VDC

Output Amps

30 Amps

Load Regulation

± 0.5%, typ (10%-FL, Note 7)

Line Regulation

±0.5% (note 8)

Preset Accuracy

±1%, typ (note 9)

Temperature Coefficient

±0.05%/°C

Ripple and Noise

100mV pk-pk (Notes 1,3, 10)

Over Voltage Protection

Latching, Auto Recover after fault condition is removed *

Short Circuit Protection

Latching, Auto Recover after fault condition is removed *

DC Voltage Adjust (typ.)

±6%, typ

Physical Specifications

Size (mm)

81.28 x 139.7 x 40.64 mm

Size (Inches)

3.2” x 5.5” x 1.6”

Construction

U-Channel

Weight (g)

544g

Weight (oz)

19.2oz

Notes

All specifications are typical at nominal input, full load, and 25°C unless otherwise noted