Order by phone: 1-800-823-8082 / +1-508-964-6300 M-F 8:30am to 5:30pm EST

PD25 25w Power Supplies

Universal AC input

Low leakage current ? 0.5mA

Protections: Short circuit / Overload / Over voltage

Fixed switching frequency at 100KHz

Cooling by free air convection

High reliability

Model Number

Output Voltage

Output Amps

Minimum Load Requirement

Load Regulation

Line Regulation

Temperature Coefficient

Ripple and Noise

Voltage Tolerance

Over Voltage Protection

PD25A

5 Volts(DC) /12 Volts(DC)

2.1 Amps/ 1.2 Amps

0.2~2.5Amps/ 0.1~1.5Amps

±1.0%/ ±4.0%

±0.5%/ ±2.0%

±0.03% / °C (0-50°C), 5Volts(DC)only

50mVpk-pk/150mVpk-pk (note 1)

±2.0%/ ±6.0% (Note 2)

5.75~6.75Volts/ 13.8~16.2Volts

PD25B

5 Volts(DC)/ 24 Volts(DC)

2.1 Amps/ 0.8 Amps

0.2~2.0Amps/ 0.1~1.0Amps

±1.0%/ ±4.0%

±0.5%/ ±2.0%

±0.03% / °C (0-50°C), 5Volts(DC)only

50mVpk-pk/200mVpk-pk (note 1)

±2.0%/ ±6.0% (Note 2)

15.75~6.75Volts/ 27.6~32.4Volts

PD2505

5 Volts(DC)/ -5 Volts(DC)

2.5 Amps/ 2.5 Amps

0.1~3.0Amps/ 0.1~2.5Amps

±4.0%/ ±4.0%

±1.0%/ ±1.0%

±0.03% / °C (0-50°C), 5Volts(DC)only

50mVpk-pk/50mVpk-pk (note 1)

±6.0%/ ±6.0% (Note 2)

5.75~6.75Volts/ -5.75~6.75Volts

PD2512

12 Volts(DC)/ -12 Volts(DC)

1.0 Amps/ 1.0 Amps

0.1~1.2Amps/ .1~1.2Amps

±3.0%/ ±3.0%

±0.5%/ ±0.5%

±0.03% / °C (0-50°C), 12Volts(DC)only

50mVpk-pk/50mVpk-pk (note 1)

±4.0%/ ±4.0% (Note 2)

13.8~16.2Volts/ -13.8~16.2Volts

PD2515

15 Volts(DC)/- 15 Volts(DC)

0.8 Amps/ 0.8 Amps

0.1~1.0Amps/ 0.1~1.0Amps

±3.0%/ ±3.0%

±0.5%/ ±0.5%

±0.03% / °C (0-50°C), 15Volts(DC)only

50mVpk-pk/50mVpk-pk (note 1)

±4.0%/ ±4.0% (Note 2)

17.3~20.3Volts/ -17.3~20.3Volts

PD25 series

Input Specifications

Environmental Specifications

General Specifications

Input Voltage Range

90-264VAC / 120-370 Volts(DC)

Frequency Range

47~63Hz

Inrush Current

32 Amps (cold start)

Input Current

0.65 Amps max @115VAC, 0.40 Amps max @ 230VAC

Leakage Current

< 0.5mAmps / 240VAC

Harmonic Input Current

Compliance to EN61000-3-2,-3

Operating Temperature

-10°C to +60°C (See Derate Curve)

Storage Temperature

-20°C to +85°C, 10~95% RH

EMI

Compliance to EN55022 (CISPR22) Class B

MTBF

507.9K Hrs min, MIL-HDBK-217F (25°C)

Vibration

10~500Hz, 2G10min./1cycle, period for 60min. each along X, Y, Z axes

Cooling

free air convection

EMS

Compliance to EN61000-4-2,3,4,5 light industry level, criteria A

Isolation

3000VAC

Isolation Input-Ground

1500VAC

Isolation Output-Ground

500VAC

Insulation Resistance

≥ 100MΩ / 500Volts(DC)

Efficiency

75% typ.

Safety Approvals

UL60950-1 TUV EN60950-1 Approved

Output Specifications

Output Voltage

5 Volts(DC)/12 Volts(DC)

Output Amps

2.1 Amps/1.2 Amps

Output Amps 200 LFM

Minimum Load Requirement

0.2~2.5Amps/0.1~1.5Amps

Load Regulation

±1.0%/±4.0%

Line Regulation

±0.5%/±2.0%

Temperature Coefficient

±0.03% / °C (0-50°C), 5Volts(DC)only

Ripple and Noise

50mVpk-pk/150mVpk-pk (note 1)

Voltage Tolerance

±2.0%/±6.0%

Over Voltage Protection

5.75~6.75Volts/13.8~16.2Volts

Over Current Protection

Above 105% rated output power Hiccup mode, auto recover

Over Temperature Protection

Tj 135°C typ. (U1) detect on main conrol IC. Shutdown o/p voltage, re-power

Rise Time

250mS, 50mS / 230VAC 250mS, 30mS / 115VAC

Hold Up Time

100mS / 230VAC 16mS / 115VAC

Physical Specifications

Size (mm)

107 x 61 x 28 mm

Size (Inches)

4.2” x 2.40” x 1.10”

Weight (g)

150g

Weight (oz)

5.29oz

Notes

1. Ripple and Noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47 uf parallel capacitor.

All specifications are typical at nominal input, full load, and 25°C unless otherwise noted

Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.