MPS65 65w Power Supplies
|
Model Number |
Output Voltage |
Output Amps |
Load Regulation |
Ripple and Noise |
Voltage Tolerance |
Over Voltage Protection |
DC Voltage Adjust (typ.) |
Efficiency |
|
3.3 Volts(DC) |
12 Amps |
±3.0% |
80mVpk-pk (note 1) |
±3.0% (note 2) |
3.8~4.46Volts(DC) Hiccup mode, auto recover |
2.97~3.63Volts(DC) |
66% |
|
|
5.0 Volts(DC) |
12 Amps |
±3.0% |
100mVpk-pk (note 1) |
±3.0% (note 2) |
5.75~6.75Volts(DC) Hiccup mode, auto recover |
4.5~5.5Volts(DC) |
74% |
|
|
7.5 Volts(DC) |
8.0 Amps |
±3.0% |
100mVpk-pk (note 1) |
±3.0% (note 2) |
8.63~10.1Volts(DC) Hiccup mode, auto recover |
6.75~8.25Volts(DC) |
76% |
|
|
12 Volts(DC) |
5.2 Amps |
±2.0% |
100mVpk-pk (note 1) |
±2.0% (note 2) |
13.8~16.2Volts(DC) Hiccup mode, auto recover |
10.8~13.2Volts(DC) |
77% |
|
|
13.5 Volts(DC) |
4.7 Amps |
±2.0% |
100mVpk-pk (note 1) |
±2.0% (note 2) |
15.5~18.2Volts(DC) Hiccup mode, auto recover |
12.2~14.85Volts(DC) |
78% |
|
|
15 Volts(DC) |
4.2 Amps |
±2.0% |
100mVpk-pk (note 1) |
±2.0% (note 2) |
17.25~20.25Volts(DC) Hiccup mode, auto recover |
13.5~16.5Volts(DC) |
79% |
|
|
24 Volts(DC) |
2.7 Amps |
±2.0% |
100mVpk-pk (note 1) |
±2.0% (note 2) |
27.6~32.4Volts(DC) Hiccup mode, auto recover |
21.6~26.4Volts(DC) |
80% |
|
|
27 Volts(DC) |
2.4 Amps |
±2.0% |
100mVpk-pk (note 1) |
±2.0% (note 2) |
31~36.45Volts(DC) Hiccup mode, auto recover |
24.3~29.7Volts(DC) |
80% |
|
|
48 Volts(DC) |
1.35 Amps |
±2.0% |
100mVpk-pk (note 1) |
±2.0% (note 2) |
55.2~64.8Volts(DC) Hiccup mode, auto recover |
43.2~52.8Volts(DC) |
80% |
MPS65 series
|
Input Specifications
Environmental Specifications
General Specifications
|
Output Specifications
Physical Specifications
Notes 1. Ripple and Noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47 uf parallel capacitor. 2. Tolerance: includes set up tolerance, line regulation and load regulation. 3. Mounting holes M1 and M2 should be grounded for EMI purposes. All specifications are typical at nominal input, full load, and 25°C unless otherwise noted Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. |