Universal AC input |
|
|
Low leakage current ≤ 0.3mA |
|
|
Protections: Short circuit / Overload / Over voltage / Over temperature |
|
|
Fixed switching frequency at 45KHz |
|
|
Cooling by free air convection |
MPS45 45w Power Supplies
|
Model Number |
Inrush Current |
Output Voltage |
Output Amps |
Minimum Load Requirement |
Load Regulation |
Ripple and Noise |
Voltage Tolerance |
Efficiency |
|
15 Amps @ 115VAC Input, 30 Amps @ 230VAC (cold start) |
3.3 Volts(DC) |
8.0 Amps |
0~10.7 Amps |
±3.0% |
80mV pk-pk (note 1) |
±3.0% (note 2) |
65% |
|
|
16 Amps @ 115VAC Input, 30 Amps @ 230VAC (cold start) |
5 Volts(DC) |
8.0 Amps |
0~10.5 Amps |
±3.0% |
100mV pk-pk (note 1) |
±3.0% (note 2) |
72% |
|
|
17 Amps @ 115VAC Input, 30 Amps @ 230VAC (cold start) |
7.5 Volts(DC) |
5.4 Amps |
0~7 Amps |
±3.0% |
100mV pk-pk (note 1) |
±3.0% (note 2) |
75% |
|
|
18 Amps @ 115VAC Input, 30 Amps @ 230VAC (cold start) |
12 Volts(DC) |
3.7 Amps |
0~4.4 Amps |
±2.0% |
100mV pk-pk (note 1) |
±2.0% (note 2) |
76% |
|
|
19 Amps @ 115VAC Input, 30 Amps @ 230VAC (cold start) |
13.5 Volts(DC) |
3.3 Amps |
0~3.9 Amps |
±2.0% |
100mV pk-pk (note 1) |
±2.0% (note 2) |
76% |
|
|
20 Amps @ 115VAC Input, 30 Amps @ 230VAC (cold start) |
15 Volts(DC) |
3.0 Amps |
0~3.5 Amps |
±2.0% |
100mV pk-pk (note 1) |
±2.0% (note 2) |
77% |
|
|
21 Amps @ 115VAC Input, 30 Amps @ 230VAC (cold start) |
24 Volts(DC) |
1.9 Amps |
0~2.2 Amps |
±2.0% |
100mV pk-pk (note 1) |
±2.0% (note 2) |
78% |
|
|
22 Amps @ 115VAC Input, 30 Amps @ 230VAC (cold start) |
27 Volts(DC) |
1.7 Amps |
0~1.95 Amps |
±2.0% |
100mV pk-pk (note 1) |
±2.0% (note 2) |
78% |
|
|
23 Amps @ 115VAC Input, 30 Amps @ 230VAC (cold start) |
48 Volts(DC) |
1.0 Amps |
0~1.1 Amps |
±2.0% |
100mV pk-pk (note 1) |
±2.0% (note 2) |
78% |
MPS45 series
|
Input Specifications
Environmental Specifications
General Specifications |
Output Specifications
Notes 1. Ripple and Noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47 uf parallel capacitor. 2. Tolerance: includes set up tolerance, line regulation and load regulation. 3. Mounting holes M1 and M2 should be grounded for EMI purposes. All specifications are typical at nominal input, full load, and 25°C unless otherwise noted Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. Physical Specifications |